Tender For supply of power contactor 4 pole 200amp,1000 vac,coil voltage 415 vac,2no +2nc aux.contacts,with surge suppressor,as per serial no 3,and item no k-01,of bill of material of rdso spec no rdso/pe/spec/ac/0184-2015 rev.1 used for feeder contactor net 1,net 2, suitable for lhb type ac coaches switchboard cabinet [k-01 ]
Tender For supply of hog a & b main power contactors, 3 pole, 1000v ac, 50hz, suitable for 500 kva, 750v ac on load switching under ac-6a category at temperature of 70 degree c & coil voltage415v ac+ 10%-20% with surge suppressor, 2no+2nc, as per rdso spec no. rdso/pe/spec/d/tl/0195-2019 (rev.-0) suitable for switchboard cabinet for hog compliant lslrd coaches. make as per bom, siemens modelno. 3tf69448 cq7z a02, abb model no. af1250-30-11, [ warranty period: 30 months after the date of delivery ]
Tender For supply of supply 6.6kv switchboard at manmad pumping station tag no-hv swbd-1-manmad as per mr sl. no. 1.1 , supply 6.6kv switchboard at manmad pumping station tag no-hv swbd-2-manmad as per mr sl. no. 1.2 , mandatory spares for hv swbds at manmad terminal as per mr sl. no. 1.3 , supply 6.6kv switchboard at sanghvi pumping station tag no-hv swbd-1-sanghvi as per mr sl. no. 1.4 , supply 6.6kv switchboard at sanghvi pumping station tag no-hv swbd- 2-sanghvi as per mr sl. no. 1.5 , supply 6.6kv switchboard at sanghvi pumping station tag no-hv swbd-3-sanghvi as per mr sl. no. 1.6 , mandatory spares for hv swbds at sanghvi terminal as per mr sl. no. 1.7 , supply 6.6kv switchboard at gujri pumping station tag no-hv swbd-1- gujri as per mr sl. no. 1.8 , supply 6.6kv switchboard at gujri pumping station tag no-hv swbd-2-gujri as per mr sl. no. 1.9 , mandatory spares for hv swbds at gujri pumping station as per mr sl. no. 1.10 , supervision of installation work at manmad as per mr sl. no. 1.11 , performing testing and commissioning activities at manmad as per mr sl. no. 1.12 , supervision of installation work at sanghvi as per mr sl. no. 1.13 , performing testing and commissioning activities at sanghvi as per mr sl. no. 1.14 , supervision of installation work at gujri as per mr sl. no. 1.15 , performing testing and commissioning activities at gujri as per mr sl. no. 1.16 , on call visit charges for amc for 1st year at manmad as per mr sl. no. 1.17.1 , testing kit mobilizing charges for 1st year as per mr sl. no. 1.17.2 , on call visit charges for amc for 2nd year at manmad as per mr sl. no. 1.17.3 , testing kit mobilizing charges for 2nd year as per mr sl. no. 1.17.4 , on call visit charges for amc for 3rd year at manmad as per mr sl. no. 1.17.5 , testing kit mobilizing charges for 3rd year as per mr sl. no. 1.17.6 , on call visit charges for amc for 1st year at sanghvi as per mr sl. no. 1.18.1 , testing kit mobilizing charges for 1st year as per mr sl. no. 1.18.2 , on call visit charges for amc for 2nd year at sanghvi as per mr sl. no. 1.18.3 , testing kit mobilizing charges for 2nd year as per mr sl. no. 1.18.4 , on call visit charges for amc for 3rd year at sanghvi as per mr sl. no. 1.18.5 , testing kit mobilizing charges for 3rd year as per mr sl. no. 1.18.6 , on call visit charges for amc for 1st year at gujri as per mr sl. no. 1.19.1 , testing kit mobilizing charges for 1st year as per mr sl. no. 1.19.2 , on call visit charges for amc for 2nd year at gujri as per mr sl. no. 1.19.3 , testing kit mobilizing charges for 2nd year as per mr sl. no. 1.19.4 , on call visit charges for amc for 3rd year at gujri as per mr sl. no. 1.19.5 , testing kit mobilizing charges for 3rd year as per mr sl. no. 1.19.6 , site training for hv swbds supplied at manmad as per mr sl. no. 1.20 , site training for hv swbds supplied at sanghvi as per mr sl. no. 1.21 , site training for hv swbds supplied at gujri as per mr sl. no. 1.22 , unit rates for test as per attached annexure-1 as per mr sl. no. 1.23 , unit rates for 2 years o and m spare as per clause no. 4.5.3 as per mr sl. no. 1.24
Tender For supply, installation, testing and commissioning of 33kv indoor vaccum circuit breaker, replacement of 11kv indoor vacuum circiuit breaker, dismantling of existing 33kv overhead line, retrofitting in 11kv switchboard panles and development of scada based substation monitoring system including allied works and comprehensive maintainence of the complete installations at iit, kharagpur (west bengal) (2nd call).
Tender For supply of auto manual bypass rotary switch for air conditioning, current rating 16a, position: 3 (auto, manual, off), number of poles: 7, as per sr. no. 57 of bill of material (bom) of rdso specification no. rdso/pe/spec/ac/0184-2015 (rev-1), confirming to rdso specification no. rdso/pe/spec/ac/0184-2015 (rev-1), suitable for use in switchboard cabinet of lhb type ac coaches. make: l&t / salzer, cat. no. 16a-d16-61031-b13-fhyr only. ]
Tender For supply of switchboard lv drawout with acb d d - supply as per mr item from s. no.01.001 to s.no. 01.006.04 - lumpsum , sitework as per mr from item no.02.001 to item no. 02.005 - lumpsum , mandatory spares as per mr from item no.04.001 to item no. 04.005 - lumpsum , supervision as per mr item no.08.001 tag no.08 472-pmcc-101 , supervision as per mr item no.08.002 tag no.08 472-epmcc-102 , supervision as per mr item no.08.003 tag no.08 472- mcc-301 , supervision as per mr item no.08.004 tag no.08 472-asb-401 , supervision as per mr item no.08.005 tag no.08 472-sas , supervision as per mr item no.08.006 tag no.08 472-bd-101 a-b , training at vendor works as per mr item no.10.001 tag no.10 472-pmcc-101 , training at site as per mr item no.11.001 tag no.11 472-pmcc-101