Get complete information related to latest Door Frame Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Door Frame Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Door Frame Tenders.
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, doorframe metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
Tender For supply of flap doorframe with panel.drawing - rdso drawing no:- wd-90030-s-66, alt -10, item no.- 3. mat. spec. - as per drawing with latest revisions and amendments. [ warranty period: 30 mo nths after the date of delivery ]
Tender For corrigendum : supply of repair of high definition camera with ni vision capability poe ip , utp cable cat 6 , nvr with i p and 2 tb hard disc 16 port , repair of ptz programming console , repair of display monitor 40 inch , repair of boom barrier with tyre killed , ptz camera 100 mtr , repair of mega phones , repair of license plate camera , repair of rfid sys with lan , repair of rfid cards with lanyard , switch 24 port 1000mbps , repair of management console , repair of servers , repair of biometricd gate lock , repair of search light , repair of hhm detector , electrical siren 2 km , repair of integrated racks , repair of ups 1 kva offline , repair of ups 5 kva online with 1 hrs backup , ofc 4 core , monitor 18.5 inch , hand held rfid system , repair of doorframe metal detector , media converter
Tender For language lab establishment at diet u s nagar - computer 1.11th gen intel core i3-1215 2.8gb ram 3.500 gb hdd 4.windows 11 and microsoft office 21 5. 21.5 screen (monitor) 6.keyboard 7.mouse 8.ups input voltage (standard range) 100 v - 300 v; charging current (standard) : 10 amps 1 amps, output power- 760 watts. rated capacity- 600 va; efficiency (battery mode) > 80%.backup 45 minutes. offline ups 9. wireless mic with noise cancellation, bluetooth 4.1 csr chip; 10m wireless range; 8 hours of talk-time; universal earphone; rotatable earbud; hd mic; lightweight,90mah li-polymer battery; 200hrs of standby time; 1.5 hours charging time; micro usb charging cable included, transmission distance : up to 10 meters from the paired device frequency range : 20hz-20khz impedance: 32 ohms 10 projector 11 projector screen 6x4 (with sitc), digital content (software) licence of the software is valid for 3 years.server based protocol with all the aspects of grammar, speaking, comprehension, recording etc. caters to all levels: basic to advanced . based on the dynamic immersion principle, which emphasizes natural learning. there is no forced learning. speech recording password security to separate teachers and students workspace clear and comprehensive reporting system, flyers ,posters related to english language the lab should be equipped with kids story books and comics interesting wall paintings and drawing related to english language and literature to catch the imagination of the students two soft board (6 * 3 ), creative interior conceptualisation with materials : flooring feet mat with fixing with chemical including all labor charges ( 500 square feet) ., lighting 1. power points 2.switch points 3.ordinary points wire as per requirement - electrical points - ac points (wire 4mm with branded switch and wire, complete with switches, wire and fixing and accessories, power point 2.5 mm wire and switch of branded company ,complete with fixing) electrical points - ordinary points (1.5 mm and 1 mm wire complete with switch board and all accessories) 4.wall fans 5.tube light with fixing 24 watt led tube, painting (2000 sq feet) complete wall and ceiling with two coats of putty & primer and 2 coat of enamel paint. complete work with fixtures. one outer wall should be designed and decorated as per theme of english lab with acrylic sheet sign board of english lab.(with sitc), furniture : 5 computer table, 5 students chair - frame made up of crc pipe, 16 quage pipe od 19*38 sitting height 18 total height chair 30 powder coated frame. blow mould seat and back (room sitting plan may vary as lab setting ), one.teacher table size 3 *2 *2.5 one drawer and one doorframe 18 mm pre laminated particle board pasted from through feed 2mm rehau beading top thickness 25mm pasted with 2mm rehau beading, one teacher chair mid back revolving chair, mesh chair tilt mechanism,crome base pp arm rest (with sitc), offline teacher training of minimum 70 teachers and online support for at least one year., other accessories : installation kit /vga/hdmi. (with sitc)
Tender For annual repair and maintenance of work to supreme court judge bungalow under 2/i sub division during 2024-25 sh providing and fixing of mondey spikes bird spikes on parapits chajjas etc of bungalow and wooden moulded beading around the doorframes in b no 7a mln marg and 15 tughlak road
Tender For provisioning of upvc partition and doors in ro building - hydraulic door closer , upvc doorframe , upvc door , dismantling al , upvc partitions , upvc door 1 , allied item