Web Analytics Made Easy - StatCounter

Drill Machine Repair Tenders

Get complete information related to latest Drill Machine Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Drill Machine Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Drill Machine Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :38207858 Due date: 20 Nov, 202420 Nov, 2024 NA
Tender For supply of drilling fixture for cbc coupler as per frontier drawing no. fasl/cc/df/1676.the material should be supplied with guarantee/ warranty certificate and work test certificate. [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :38005126 Due date: 18 Nov, 202418 Nov, 2024 45.72 Lacs
Tender For corrigendum : provn of 02 in nos bore wells alongwith associated items at icgs mundra - material and labour for drilling of 02 nos pilot/trial bore by direct rotary rig method including all t&p through any kind of starta (soil, kankar, boulder or soft or hard rock) down up to 150 m depth below ground level by using suitable drill bit according to levering of casing pipe including the cost of mud pit, channels, etc and disposal of soil obtained to a distance not exc. 1 km away complete all as specified. note:- (i) the drilling shall be continued up to specified depth and in case sticky clay occurs in between the drilling must be stopped and hydrologist of gws & sb shall be contacted & eggr-in-charge shall be informed.(ii)cost of this consultant shall be borne by contractor (iii) taking the samples from the bore well cutting for every 3 meter interval and every change in strata if less than 3meter. (iv) preparation of litho logs based on these samples.(v) drill time log to be prepared and prescribed., (vi) aquifer performance tests at constant discharge with draw down and recovery reading.(vii) after completion of pilot bore, the contractor shall have to arrange for electro eater logging test of each bore.(viii) contractor have also produced bore well water test report for drinking water parameters before levering of motor and pump.(note:- if water quality not found fit for domestic purpose use then all other connected items of trial bore will not be executed.) , supply assembling, jointing, lowering and fixing in the bore hole pvc casing pipe of nominal dia 315 mm (medium well) ,10 kg/cm2 working pressure, confirming to is 4985-2000 including providing pea gravel of 8 mm to 4.6mm size for packing around the casing/slotted pipe in bore well all as specified and directed. make: astral/ashirwad/ajay/sfmc, all as per item no 2.00 above but slotted pipe. , supply, assembling, jointing, lowering lead free pvc column pipes of nominal dia 65 mm, od 75 mm (min), non toxic, pressure 16 kg/cm2 with and including top and bottom adaptor (ss) and accessories like epdm ring and double ss stud all as spd and directed by engineer-in-charge. make: astral/ashirwad/ajay/sfmc, development of tube well with compressed air by means of air compressor of suitable capacity not less than 300 cfm and over pumping using suitable capacity pump to make available water free from turbidity complete all as specified and directed by engineer-in-charge., m & l for conducting yield test for the bore well by continuously pumping for 24 hours by using a submersible pump set to determine safe pumping yield and produced water test report of samples which is collect every hour complete as directed by the engineer-in-charge. [ all arrangements for yield test shall be made by contractor and cost for the same borne by contractor ], supply and fix ms reducer, bail plug, top cover made of 3mm thick ms plate for bore well in two half sections having a hole of 75 mm bore in centre to accommodate pvc pipe and submersible cable suitable for fixing to the pvc casing pipe top, electric logging and simple strata box including provision of 2 sets of ms clamps made of 50x6mm ms flat including nuts, bolts, etc. including one coat of epoxy primer and two coats of epoxy paint wherever necessary complete all as specified and directed by engineer-in-charge., supply, install, test and commissioning of submersible pump stainless steel body electric driven with submersible motor, water lubricate, 3 phase, 10.0hp (appx) 415 volts, 50 hz with suitable submersible electric motor suitable for discharge of 2 liters per second against total head of 125m in the bore complete all as specified and directed by the engineer-in-charge. [ note : column pipe, submersible cable and control gear will be measured and paid separately]. [make: kirloskar / crompton / ksb], supply, install, test and commissioning of submersible pump stainless steel body electric driven with submersible motor, wa

Central Government/Public Sector

CTN :38184951 Due date: 02 Dec, 202402 Dec, 2024 NA
Tender For supply of 300067498 , 310022341 , 300089748 , 300023095 , 310022365 , 310022364 , 300120574 , 300152952 , 300152953 , 300152954 check valve swing type, size: 6" 150#, raised face flanged ends, material: body sa216 gr. wcb, seat sa 105 and 13% cr faced, disc sa216 gr. wcb and 13 % cr faced, hinge pin 13% cr, body to bonnet connection bolted, face to face dimension as per asme b16.10, flanges and drilling as per asme b16.5, valve testing as per api598., gate valve,rising stem,flexible disc,material:body astm a216wcb,disc a 216 wcb with 13% chrome facing, size 8",#150,end connection:flanged ised face as per ansi b16.5.design standard:api 600,inspection & testi ng as per api 598., gate valve with bolted bonnet, outside screw & yoke; size: 6" nb x 150#; ends: flanged (raised face serrated) moc: (1) body & bonnet: astm a 216 gr wcb, (2) stem: astm a182 gr. f6a, (3) seat ring: astm a 105 + hardfaced with stellite #6 (api trim #5), (4) disc / wedge : astm a 216 gr wcb + hardfaced 13% cr steel (api trim #5), (5) bonnet gasket: spirally-wound ss 304 with graphite filler, (6) yoke sleeve: astm a439 type d2 (7) gland & gland bush: astm a 105. (8) stem packing: graphite with braided end rings, (9) back seat: hardfaced 13% cr steel (api trim #5), (10) bonnet bolts & nuts: astm a 193 gr b7 & astm a 194 gr 2h, (11) gland bolts / eye bolts & nuts: astm a 193 gr b7 & astm a 194 gr 2h; (12) hand wheel : ductile iron. compliance standards: design standard: api 600; face to face dimensions: as per ansi b16.10; flange drilling:as per ansi b 16.5; pressure & temperature rating

Central Government/Public Sector

CTN :38191491 Due date: 19 Nov, 202419 Nov, 2024 NA
Tender For supply of elctrician tool analog kit 200a, screw driver with individual handel and arm - 2 nos, arm dia screw driver 3 mm,3.5 mm, 4 mm, 5 mm, 6 mm, 8 mm, and 10 mm, arm length screw driver - 50 mm, 75 mm, 100 m m, 125 mm, 150 mm, 175 mm, 200 mm, 250 mm, 300mm, hexagonal socket wrench with bits, ratchet hand scr ew driver ( reversible high torque type), allen key set 12 pieces (2mm to 14 mm), combination plier with tool kit 1,2,3, size of combination plier high grad forged steel with insulation handle - 6 inch, number of flat nose plier 1, 2,3 and size 6,7,8 inch, wire stripper or cutter, ball pin hammer with rubber habdle, torch 9 pearl led flashlight, masonary drill bit size - 5 mm, knife blade of high quality - 0.25 mm, steel made measuring tape side ? 3 meters, availability of hand drilling machine, soldering iron, test lamp, cutting nippers size - 6,7,8 inch, rubber gloves, ha nd saw with plastic handle with carbon steel blade, screw driver material alloy steel, warranty 01 year, make- ta pariya or equivalent. [ warranty period: 12 months after the date of delivery ]

Central Government/Public Sector

CTN :38172282 Due date: 22 Nov, 202422 Nov, 2024 NA
Tender For supply of drilling fixture for cbc coupler as per frontier drawing no. fasl/cc/df/1676.the material should be supplied with guarantee/ warranty certificate and work test certificate, make- frontier. [ warra nty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :37963382 Due date: 16 Nov, 202416 Nov, 2024 29.00 Lacs
Tender For corrigendum : repair and maintenance to lt electric supply and connected works at afs hakimpet under ge (af) hakimpet - note:-1. the contractor should visit the site before quoting the tender to know the working condition of the station.2. all requisite safely measures are to be adopted by contractor on site.3. the contractor shall provide and deploy sufficient electrician (as approved by ge / engineer in charge) shall report at 9:00 hrs to je e/m / engineer in charge to collect the complaints job card in working days and complete the same completed within 24 hrs.4. the complaints shall be rectified within 24 hrs if the complaints is/are not attended / not completed within 24 hrs (except repair/replacement of major items) recovery will be done at rs 500 per complaint per day.5. for major parts like replacement of mcb, dbs, mccbs etc should be rectified within 3 working days, if the contractor not rectify within time then recovery will be done at rs 1000 per complaint per day.6. after completion of job work complaint, the contractor has to produce job card duly signed by user & je / engineer in charge.7. if contractor failed to provide their electrician to attend the complains then recovery will be done at rs 1000 per day.8. the contractor should procure minimum 50% of the materials for all items as per boq (other than paints) mentioned in this ca, within 20 days after getting sample approval and kept in safe custody so that no delay in work due to non-availability of materials will be faced. contractor should ensure during the cause of work that he has minimum 25% of materials with him till the completion of work. if contractor fail to complete the work within contract due to lack of fittings a penalty of 20% shall be applicable on quoted rates by the contractor.9. in repair works, rate quoted for demolition /dismantling /taking down is deemed to be inclusive of removing the same from site and station.10. in maintenance works, the contractor should maintain separate registers for repair works. day to day complaints should be noted in those registers with si nos of complaints, location qty of work, status of complaints and signature of in charge and stamp of the office. formal will be given from concern age office. the contractor should obtain the signature of in charge on the same day of work. these register to be submitted to je (e/m) on every weekend without fail.11. the contracts involving working at elevated locations of buildings, contractor should ensure proper safety arrangements as per norms. wearing safety belts and helmets are mandatory. a penalty of rs 1000 per day will be recovered from contractor if safety norms are not followed.12. after completion of work, no stores/debris/ loose items be kept at work site or dumped inside station . entire area to be cleared and waste material be taken outside from the station ., excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting in hard/dense soil for laying of cables/ for erection of poles/ for stay assembly etc complete all as specified and directed by engineer-in-charge., boaring/ drilling (horizontally ) of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including hdpe pipe of 80 mm dia suitable for 0.4 mpa working pressure. all as specified and directed by engineer in charge.., supply and spread clean dry river sand in trenches for cushioning of cable complete all as specified and directed by engineer-in-charge. (note: punned down thickness only shall be measured for the purpose of payment), supply and fix precast concrete cable covers class lv type 1, flat size 250 x 150 x 40 mm m-20 grade concrete laid dry for cable protection complete all as specified and directed., returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by engineer-in-charge., removing surpl

State Government

CTN :38121172 Due date: 20 Nov, 202420 Nov, 2024 NA
Tender For procurement of material for the schemes of zila parishad, nalanda. - course book, magazine, fictions and nonfiction books, competitive books, novels, newspapers, comics, story telling books, biograghy and autobiograpy books, books, lrature book, drilling of borewell 300mm/250mm dia, moon climber, circular swing, 4 way dancing see saw, troo slider (gi sheet), mankey climber, swing two teater, rocking boat, parrallel bar, mgr, monitor, keyboard, mouse, printer, ups, scaner, epu, pendriive, projector, wooden laminated/aluminium modem, door/window, calling fan, led bulb, r.d. (drinking water), 15 watt led bulb, 6 to 32 amp sp mcb, 1200 mm sweep celling fan, 400 mm, 230 volt, ac exhalist fan, 381 mm, 280 volt, ac exhaust fan, 400 mm, 230 volt, ac wall/cabing fan, stablizer, 5 hp motor, 3 hp motoi, regulator, electric pvc pipe, electric five pin socket, electric two pin socket, electric five pin plug, electric two pin plug, tube light, batten, 100 mm x 100 mm x 60 mm deep pvc/metal, box, 75 mm x 75 mm x 60 mm deep pvc/metal box, 16 amp socket, fan regulator 2 module, piano fan regulator 01 module, ??? db 4 way, switch, board, installation charge, electric wire, 2 hp motor, 1.5 hp motor, 3hp statrter, 2hp statrter, 1.5 hp statrter, adapter, submersible wire, mcb control pannel, street light, high mass pole with bracket 50 watt hd light, iot device, ac 2 tone, ac steplizer, starter repair, submersible repair/new, stabilizer repair/new, pa mixer amplifier ssb-120, pa mixer amplifier cma-5400, chairman unit cmc-5100, delight unit cmd-5200, pa wall speaker asx-3128t, awm-7200u2 microphone, 15 mtr. mic wire falcon, speaker cable falcon coil 90mtr., cassette ac 3.8 tone, cassette ac 2.0 tone, copper pipe, drain pipe, four copper wire, choki stand, book self, chair, study table, news paper stand, bench, desk, office table, black board, pvc carpet, steel almirah, foldable wheel chair, battery box, steel rack, dining table, tea table, floor carpeting, visitor chair, fiber chair, 3 seater bench, high mask pole (bottom, thickness, base plate, foundation bolt, battery box, arm), lithium battery, 50 watt led, 150 watt solar panel, hire charge of air compressor machine, hire charge of boring machine, pcc cutting machine, ms angle, ms channel, ms clamp 20 mm, ms clamp 63 mm, clamp d, ms patti, ms pipe 50 mm, tank clamp, colour seat 10' x 48", colour seat 12' x 48", colour seat 14" x 48, angle rack, library table, false celling (with material), flooring (with material), paint and putty (with material), venner with glossy polish (with material), wall paneling (with material), cupboard (mr ply) (with material), furniture repairing work (with material), wall paneling louvers work (with material), sofa (with material), upvc window (with material), pvc wall paper (with material), parda (with material), pvc wall pilling, stone notice board size 2.5feet 2feet &, 2feet*1.5feet, bench, desk, office table, black board, pvc carpet, steel almirah, foldable wheel chair, battery box, steel rack, dining table, tea table, floor carpeting, visitor chair, fiber chair, 3 seater bench, high mask pole (bottom, thickness, base plate, foundation bolt, battery box, arm), lithium battery, 50 watt led, 150 watt solar panel, hire charge of air compressor machine, hire charge of boring machine, pcc cutting machine, ms angle, ms channel, ms clamp 20 mm, ms clamp 63 mm, clamp d, ms patti, ms pipe 50 mm, tank clamp, colour seat 10' x 48", colour seat 12' x 48", colour seat 14" x 48, angle rack, library table, false celling (with material), flooring (with material), paint and putty (with material), venner with glossy polish (with material), wall paneling (with material), cupboard (mr ply) (with material), furniture repairing work (with material), wall paneling louvers work (with material), sofa (with material), upvc window (with material), pvc wall paper (with material), parda (with material), pvc wall pilling, stone notice board size 2.5feet 2feet &, 2feet*1.5feet, white

CTN :38130742 Due date: 21 Nov, 202421 Nov, 2024 NA
Tender For supply of drill holder helical flute with thru coolant facility for dia 40mm drilling insert cel 140mm to 167m , hss super cobalt drill insert dia 40mm with tiain coated for drilling of alloy steel material having

corporations/Associations/Others

CTN :38144113 Due date: 22 Nov, 202422 Nov, 2024 NA
Tender For em i rectification of defective stator water expansion tank level regulator by fabrication of new level regulator bushing phosphors bronze material including cutting drilling machining and blue matching work and assembling and allied works in unit ii

CTN :38108539 Due date: 02 Dec, 202402 Dec, 2024 NA
Tender For (1)supply of high availability single section digital axle counters(hassdac) with dual sensor system as per rdso spec. no:rdso/spn/177/2012 (ver.3) with dual track sensor device or latest amended up to date of tender opening. this includes the supply of high frequency web mounting type tx coil/rx coil- 04 nos., vr/pr box duly wired-02 nos., vital relays-04 nos., pr relays- 04 nos., clamp with deflector plates & hardware- 08 nos., dual display reset box with auto resetting facility- 02 nos., surge voltage protection d evices and filter card to be mounted on din rail etc- 02 nos. for complete installation & testing & commissio ning of (hassdac) system. note: one set of hassdac system will include equipment required to monitor one up line or one dn line of a full block section between two stations. (2) installation, testing & commissi oning of high availability single section digital axle counter (hassdac), single section type system complet e with track devices and other associated accessories to be ensured by oem. this include fixing of device, r elays, wiring, lacing/dressing, cable termination with lug eyelet, drilling holes in rails, installation of track d evices and make it functional along with existing ufsbi/block instrument. material required other than supp ly item of hassdac in item no. 1 above shall be arranged by firm to make it functional. [ warranty perio d: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up