Get complete information related to latest Dust Filter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Dust Filter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Dust Filter Tenders.
Tender For corrigendum : tender for supply of installation of screw compressor for hvac system - screw compressor rc2-470a-vi26 , installation and recommissioning charges , 48hrs. performance test charges , r134a refrigerant gas for compressor , oil solest for compressor , driver unit for compressor , filter drier for compressor , exv ets250b for compressor , temperature sensor for compressor , motor protector for compressor , pressure sensor for compressor , filetr drier core for compressor
Tender For supply of compressor plc panel model electronikon ii , air and oil filters , refrigerant gas top up , separator , filter catridge , oil and other valve related consumables
Tender For providing of customized amc/cmc for pre-owned products - customized amc/cmc for pre-owned products - galley equipment; various brand; comprehensive maintenance contract (cmc); 24 hour response; yes--work for contract for annual maintenance contract of galley equipment at ins pallava-1. the contractor shall carry out preventive maintenance of the following, equipment every quarter: -, 1.1. cooking & heating equipment: -, - ss bme 304 grade hot bain marie, - electric hot plate (galley & wr), - 5 burner gas range (120"30"24"), - 2 burner gas cooking range with storage platform, - semi-automatic bench type industrial oven (3 deck), - electric griller chicken, - microwave oven / lg 30 ltrs mc 808, - food storage heating element electric with 04 containers (6kg, 304, grade ss), tasks:, - cleaning of heating surfaces and trays, - inspection and calibration of thermostats (half yearly), - checking and tightening of electrical terminals, - replacement of heating coils, knobs, and switches if required, - inspection of insulation and safety cut-off systems, - cleaning of exhaust vents and heat dispersion units, page 5 of 10, 1.2. mixing & processing equipment: -, - domestic blender/dough kneader sbwg 1500 watt 40 kgs, - cast iron commercial mixer 5 ltr, - wet grinder 10 kg cap, - pulvariser machine with stand, - vegetable cutting machine (up to 200 kgs), - potato peeler automatic 1.5 kw, tasks:, - cleaning of blades, jars, and grinding surfaces, - lubrication of moving parts, - inspection of motor windings and bearings, - calibration of speed controls, - replacement of belts, couplings, and safety covers, 1.3. refrigeration & cooling equipment: -, - ss icecube machine, - microwave oven, tasks:, - cleaning of condenser coils and drip trays, - checking refrigerant levels and gas charging (if required), - calibration of thermostats (half yearly), - inspection of compressors and insulation, - replacement of filters and seals, page 6 of 10, 1.4. exhaust & ventilation systems: -, - exhaust system for gas range, - exhaust hood with filter box and accessories, - 5 hp motor blower, tasks:, - cleaning of filters and ducts, - inspection of motor and fan bearings, - tightening of electrical connections, - replacement of worn-out belts and blades, - checking airflow and suction capacity, 1.5 cleaning & hygiene equipment: -, - wet and dry duty cleaning industrial vacuum cleaner 220smvco1, - commercial dishwasher with dryer model deb424fp, tasks:, - cleaning of filters and tanks, - inspection of pump and motor assemblies, - descaling of internal components, - replacement of hoses, nozzles, and seals, - electrical safety checks, 1.6. lpg gas system, page 7 of 10, 2. defect rectification of all machines including replacement of defective parts., 2.1 all replaced parts/compounds should be branded make and should have a, guarantee of one year from the date of renewal., 2.2 the contractor is required to attend the defect within 24 hours of reporting the, defect through telephone., 2.3 spares using for maintenance of equipment should be the oem make., 2.4 repairs / replacement of any items should be carried out as per the actual site, requirement / technical necessity., 2.5 rate quoted is inclusive of all taxes, freight charges, packing charges, spares,, transportation, service charges etc., 3. comprehensive coverage includes, - free overhauling: as per unit requirement., - free spares: due to wear and tear during contract period., - free labour: for all listed equipment., - free electrical wiring: internal wiring repairs., - free fan motor repairs: including winding and bearing issues., - free chemical washing: during overhauling., - free transportation: for off-site servicing., - free compressor & gas charging: for refrigeration units.,
Tender For tri - annual comprehensive service contract for 02 nos of screw type air compressors, and refrigerant type air dryer at filter plant, mumbai-iii a, panjrapur.
Tender For tri-annual comprehensive service contract for 02 nos of screw type air compressors, and refrigerant type air dryer at filter plant, mumbai-iiia, panjrapur bid no. 2025_mcgm_1230333
Tender For tender for supply of m and l for point wiring complete with 1 5 sqmm nominal area pvc insulated multi stranded frls copper conductor cable unsheathed in and including pvc conduit with all fittings medium grade isi marked and pvc insulated frls copper conductor cable of size 1 5 sq mm as earth wire connected to common earth dolly suitable for mounting modular switches including modular metal flush boxes and modular face plate with cover complete all as specified and as directed by engr in charge the works includes cutting of chasis and making good disturbed surfaces and rate deemed to included in quated rate make of cable finolex polycab havells , one light fan point controlled by one switch , one switch socket outlet 3 pin 5 amp on the independent board , one switch socket outlet 3 pin 5 amp on same board , all as per item no 1 here in-before but with 2 single core pvc insulated frls and sheathed copper conductor of size 2 5 sqmm in and including pvc conduit isi marked including cutting chiseling and grouting concealed pvc conduit pipe tee elbow and bend etc and with all connecting accessories with 2 5 sqmm pvc insulated frls copper conductor as earth wire and connecting to common earth dolly for 6 pin 16 amp socket outlet on the independent board using 2 5 sqmm copper cable incl pvc insulated copeer conductor 1 5 sqmm as continued earth wire make of cable finolex polycab havells , all as per item no 1 here in before but with 2 single core pvc insulated frls and sheathed copper conductor of size 4 sqmm in and including pvc conduit isi marked including cutting chiseling and grouting concealed pvc conduit pipe tee elbow and bend etc and with all connecting accessories with 4 sqmm pvc insulated frls copper conductor as earth wire and connecting to common earth dolly for 20 amps socket outlet on the independent board make finolex polycab havells , s and f modular switch 1 way 16 amps 1 module complete all as specified and as directed by engineer in charge , s and f modular socket outlet 6a 16a 2 3 pin combined 2 module complete all as specified and as directed by engineer in charge , s and f modular switch 1 way 6 amps 1 module complete all as specified and as directed by engineer in charge , s and f modular socket outlet 6a 2 3 pin combined 2 module complete all as specified and as directed by engineer in charge , supply and fixing led luminaire 600 mm x 600 mm 35 36 watt 220 v ac recessed type with high efficiency pmma diffuser soft glare free light complete with driver holders and led lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed , supply installation commissioning and testing invertor type bee 5 star rating air cooled split unit air conditioner electric driven single phase of capacity 1 5 tr eco friendly refrigerant hi wall split units indoor and outdoor unit complete with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with 5 star rated auto restart facility 100 present copper tube and condenser including excess copper tubing if required beyond the lenght 7 5 mtrs supplied with ac unit and pvc conduit of 15mm dia not exceeding 2 5 mtr long for water drain including drilling hole through drill machine and making good to disturbed surface with cement mortar ratio 1 3 to match the existing surface complete all as specified and directed by engineer in charge make voltas blue star hitachi daikin or equivalent out of make specified in list of make , supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of plus minus 2 5 persent suitable for 1 5 ton ac operation complete all as specified and directed , supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complet
Tender For supply of mt spare c c - hose steering pump to gear , blower control module , discharge hose assy , ac refrigerant gas 134a , hose assy air filter outlet , wiring harness front , suction hose assy , assy rear door latch lh , assy vaccum hose for tc , assy vaccum hose for egr , kit pad assy front
Tender For tender for supply of split air condition : : - supply install testing and commissioning of energy efficient hi wall split type airconditioner with indoor and outdoor unit complete with inverter technology 3d airflow power chill operation cordless remote control unit and with in built air ioniser pm 2 5 filter for better indoor air quality with 5 star rating and eer 3 2 of capacity 1 5 tr with precharged cfc free refrigerant including drain pipe copper tubings of suitable dimensions cutting the holes and making good the disturbed surface with existing colour all as specified and directed by engr in charge note 1 cost of outdoor unit stand shall be included in quoted rate 2 all units shall be made of copper tubes 3 ac shall be designed to sustain 50 degree celcius outside temperature make daikin hitachi ogeneral , s and f in replacement sheet metal enclosure single pole and neutral two pin and earth plug and socket complete with one double pole mcb 20 amps for geyser ac complete all as specified and as directed , supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of pluse minuse 2 5 persent and of capacity 4 kva complete all as specified and directed , s and f of sub main wiring with pvc insulated frls unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4 sqmm nominal area drawn in and including concealed pvc conduit of suitable size as directed with and including one run of 4 sqmm multi stranded copper conductor single core pvc insulated unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed note two runs of 4 sqmm cable and one run of 4 sqmm cable of earth continuity conductor and conduit shall be a unit length , s and f of copper pipe 10 15 mm dia for indoor to outdoor connection complete all as specified and directed