Get complete information related to latest Earth Bar Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Earth Bar Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Earth Bar Tenders.
Tender For supply of wiring , ups , light , fire alarm , hvac wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable etc. as required. group c, wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm frls/hffr pvc insulated copper conductor single core cable in surface/ recessed pvc conduit, and earthing the point with 1.5 sq. mm frls/hffr pvc insulated copper conductor single core cable etc. as required. group c, wiring for circuit/ submain wiring along with earth wire with the following sizes of frls/hffr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire, wiring for circuit/ submain wiring along with earth wire with the following sizes of frls/hffr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 x 4 sq.mm +1 x 4 sq.mm earth wire, wiring for circuit/ submain wiring along with earth wire with the following sizes of frls/hffr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 x 6 sq. mm + 1 x 6 sq. mm earth wire, wiring for circuit/ submain wiring along with earth wire with the following sizes of frls/hffr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 4 x 6 sq. mm + 2 x 6 sq. mm earth wire, wiring for circuit/ submain wiring along with ) /bid number : gem/2026/b/7105844 * /dated: 13-01-2026 & & / bid document 1 / 61 earth wire with the following sizes of frls/hffr pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 4 x 10 sq. mm + 2 x 6 sq. mm earth wire, supplying and fixing suitable size gi box of 1.2 mm thickness (min.) with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required., supplying and fixing suitable size gi box of 1.2 mm thickness (min.) with modular plate and cover in front on surface or in recess ,including providing and fixing 6 pin 15 / 16 & 5 / 6 amps modular socket outlet and 15 / 16 amps modular switch, connection, etc.as required., supply, installation, testing and commissioning of 1200 mm sweep, bee 5star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b,3 nos. blades, suitable long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9,service value (cmm/w) minimum 6.85, air delivery minimum 215 cmm, 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required., supplying and fixing following way prewired triple pole and neutral, sheet steel for 415 volts on surface/recess complete with loose wire box, terminal connector for all incoming and outgoing circuits, duly prewired with suitable size frls pvc insulated multi strand copper conductor upto terminal blocks, tinned copper bus bar, neutral link, earthbar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required. (but without mcb / rccb / isolator) 4 way (4+12) double door, supplying and fixing following way prewired triple pole and neutral, sheet steel for 415 volts on surface/recess complete with loose wire box, terminal con
Tender For supply of 4 pole power contactor (k 44) 200 amp suitable for 690 v ac, coil control voltage: 168 v - 300 v ac with surge suppressor and 1 no + 1 nc auxiliary contact similar to the product type: af140-40-00-13 + cal9-11 of abb conforming to is : 13947 , pt-4/1993 , make- abb , schneider , l&t or similar. accepted make/brand: -bch. [ warranty period: 30 months after the date of delivery ]
Tender For supply for commissioning of 110 volt eot crane control panel with complete wiring consisting of following items: 1) powder coated standard mild steel control panel with minimum thichness 14 swg for body and 16 swg for doors .protection class-ip-55 and is 8623/iec 61439 - 01 nos 2) mccb 4 pole 415 volt ac,50hz,35 ka, 100 ampere conforming to standard iec 60947-2 make-l&t/havells/c&s /siemens- 01 nos 3) 3 pole forward/reverse power contactor unit 75 ampere ,coil voltage-110 volt ac,with 2no+2nc type-mnx75 ampere/110 volt ac make-l&t/havells/c&s /siemens -02 nos 4) auxiliary power contactor unit 16 ampere ,coil voltage-110 v ac with 2no+2 nc, type mnx 16 ampere/110 volt make-l&t/havells/c&s /siemens- 01nos5) electronic overload relay (20-85) ampere ,415 volt ac 50hz ,3 pole trip class 10-20 with 1 no+ 1nc as per iec 609474 make-l&t/havells/c&s /siemens- 01 nos 6) 3 pole contactor unit 50 ampere, coil voltage-110 volt with 2no+2nc for one drive rotor acceleration-03 nos make-l&t/havells/c&s /siemens 7) on delay timer for one drive 110-220 volt make-l&t/havells/c&s /siemens 8) spp (single phase preventor) 6 wire 415volt,protection class-ip 20-01 nos make-l&t/havells/c&s /siemens 9) led indicator lamp red-yellow-blue -01 nos each make- ce/kaycee/c&s 10) din channel-05 mtrs make-reputed 11) power and control terminal/connector (complete set) 12) numbering ferrule as per requirement(complete set) 13) copper cable lugs,pin &ring type ( complete set) 14) sleeves as per site requirements -01 set [ warranty period: 30 months after the date of delivery ]
Tender For supply of three pole power contactor with 2no + 2nc as specification-(1) auxiliary contact 2no + 2nc (ii) base hole dimension: dw=35mm,dh=65mm,qd=m4 (iii) current rating: ac1-45a; ac3-25a,coil voltage-110v ac ,make- l&t or siemens or havells [ warranty period: 30 months after the date of delivery ]
Tender For : supply of 240 v ac, 50 hz, 2 pole, 32 a power contactor with 2 no and 2 nc auxiliary contacts suitable and retrofittable into existing 5kva suntron make cls panel. the contactors shall be of electromagnetic air break type of robust design. the contacts shall be silver plated, bounce proof and have amplecross section for carrying the rated current continuously without exceeding the permissible temperature rise. it shall conformed to is/iec: is 13947 ( part 3 ) : 1993/i. make: l&t , abb, c&s, schneider, siemens, yule,telemechanique.or similar. [ warranty period: 30 months after the date of delivery ]
Tender For supply of 240 v ac, 50 hz, 2 pole, 65 a power contactor with 2 no and 2 nc auxiliary contacts suitable and retrofittable into existing 60a capacity suntron make cls panel the contactors shall be of electromagnetic air break type of robust design. the contacts shall be silver plated, bounce proof and have ample cross section for carrying the rated current continuously without exceeding the permissible temperature rise. it shall conformed to is/iec: is 13947 ( part 3 ) : 1993/i. make: l&t , abb, c&s, schneider, siemens,yule, telemechanique.or similar [ warranty period: 30 months after the date of delivery ]
Tender For supply of 240 v ac, 50 hz, 2 pole, 150 a power contactor with 2 no and 2 nc auxiliary contacts suitable and retrofittable into existing 30a capacity suntron make cls panel. the contactors shall be of electromagnetic air break type of robust design. the contacts shall be silver plated, bounce proof and have ample cross section for carrying the rated current continuously without exceeding the permissible temperature rise. it shall conformed to is/iec: is 13947 ( part 3 ) : 1993/i. make: l&t , abb, c&s, schneider, siemens, yule, telemechanique.or similar [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of spares for 02 nos float and boost chargers for 220 vdc and 48vdc battery bank at power house c c - 16a ammeter selector switch for main input current selection , 16a voltmeter selector switch for main input voltage selection , 10a tp ac 2 way without off auto or manual mode selection for float and boost chargers , 16a sp dc 2 way without off switch for float rectifier or load bus and boost rectifier or battery voltage selector switch , 16a sp ac 2 way without off auto c or o mode or manual boost mode selection for charger , 10a tp dc 2 way without off for boost charging of battery set 1 or 2 selection , 225a dc coil operated emergency contactor coil 220v dc auxi 1no , 185a dc coil operated contactor for boost charging battery set 1 coil 220v dc auxi 2 nc , 63a dp dc on or off switch for load isolation , 40a dc coil operated emergency contactor coil 48v dc auxi 1no , 65a dc coil operated contactor for boost charging battery set 1 coil 48v dc auxi 1 nc , filter capacitor for ripple suppression for float and boost chargers rating 100 v 2200 uf , dc to dc convertor 48v dc to 24 v dc 5 amps , 4 channel relay boards for contact multiplication of card mounted protection relays , electronic card module for avr and current limit for float charger auto and manual mode , electronic card module for avr and current limit for boost charger auto and manual mode , electronic card module for float and boost rectifier fuse fail and filter fuse fail , protection module for various fault detection and annunciation , blocking diode for float and boost charger rating 70a i avg piv 800 for fcb mode on k3 heat sink , 80 percent blocking diode stud type rating 70a i avg piv 800 on k3 heat sink , latching resistor for rectifier. 250 ohms 50 watts for float and boost chargers , 10k 1w potentiometer for auto or manual voltage adjust in float charger , 10k 1w potentiometer for auto or manual current adjust in boost charger , 2ph control transformer for power supply of avr cards prim 415 v sec 16 0 16 v ac 400ma , 3ph control transformer for synchronising of avr cards. pri 415 v sec 16 0 16 50ma , 3ph control transformer for ac u or v pri 415 v 3 phase sec 0 16 vac 1 phase 250 ma , 2 0fi control transformer for fan control supply prim 415 v 2 phase sec 190v ac 50va , scr stud type 70a with heatsink loose module only , diode free wheeling stud type 70a with heatsink loose module only , digital ac ammeter 48 x 96 sq mm class 1 ct ratio 25 or 1a auxiliary voltage 24v dc , digital ac voltmeter 48 x 96 sq. mm class 1 range 0 500v ac auxiliary voltage 24v dc , digital dc ammeter for float boost chargers and 80percentage cell tap 48 x 96 sq mm class 1 75mv dc with shunt auxiliary voltage 24v dc , digital dc voltmeter 48 x 96 sqmm class 1 range 75mv dc auxiliary voltage 24v dc , digital dc charge or discharge ammeter for battery 48 x 96 sq mm class 1 range 75mv with shunt auxi 24v dc , transportation charges for material