Web Analytics Made Easy - StatCounter

Earth Clamp Tester Tenders

Get complete information related to latest Earth Clamp Tester Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Earth Clamp Tester Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Earth Clamp Tester Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :40221359 Due date: 07 Jun, 202507 Jun, 2025 NA
Tender For corrigendum : rate contract for supply of electrical spares n minor store/hardware items, as given in the detailed boq, from govt approved reputed experienced competent n financially sound electrical contractors/firms/suppliers/joint ventures/executors/oems - part: (a) 132kv transmission lines (material ), al. alloy as per is: 617 of 1975 pg clamps 3 bolt type conforming to is: 5561-1970 (amended upto date) for acsr zebra conductor (make: rul, zi, honeywell, burma, pee, equivalent etc/ as per departmental sample provided)., p g clamp for acsr panther conductor as per relevant is/iec amended upto date and of reputed/standard make, p g clamp for acsr moose conductor as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic ct clamp (universal take off) for panther conductor with ct terminals suitable for 132kv/33kv cts as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic isolator pad clamp (universal take off) of panther conductor with pad terminals suitable for 132kv /33kv isolators as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic isolator pad clamp (universal take off) of zebra conductor with pad terminals suitable for 132kv /33kv isolators as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic breaker pad clamp (universal take off) of zebra conductor with pad terminals suitable for 132kv /33kv breakers of sf 6 type-abb,cgl, siemens, bhel/vcb type- s&s, gec alsthom, bhel, abb, siemens, megawin etc as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic ct pad clamp (universal take off) for twin acsr zebra conductor with conductor spacing 300mm and ct terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin zebra conductor with pad terminals suitable for 132kv /33kv ct as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic twin isolator pad clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) for twin acsr zebra conductor with conductor spacing 300mm and isolator pad clamp terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin zebra conductor with pad terminals suitable for 132kv /33kv isolator as per relevant is/iec amended upto date and of reputed/standard make, bimetallic ct pad clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) for twin panther conductor with conductor spacing 300mm and ct terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin panther conductor as per relevant is/iec amended upto date and of reputed/standard make, bimetallic breaker pad clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) for twin panther conductor with conductor spacing 300mm and terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin panther conductor as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic isolator pad clamp (univercial take off) conforming to is: 5561-1970 (ammended upto date) for twin panther conductor with conductor spacing 300mm and isolator terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin panther conductor with pad terminals suitable for 132kv /33kv isolator of reputed/standard make, bi-mettalic isolator pad clamp (univercial take off) conforming to is: 5561-1970 (ammended upto date) for single panther conductor of reputed/standard make, t-clamps 3 bolt type conforming to is: 5561-1970 (amended upto date) for acsr -panther-acsr panther conductor of repute

CTN :40082116 Due date: 17 May, 202517 May, 2025 NA
Tender For corrigendum : supply of spares/ stores/t&p/equipments/hardware items required from time to time for day to day operation/ maintenance/construction of power sub-transmission network of this division during the financial year 2025-26 or till the next rate contract - disc insulator 70kn b&s type, anti fog (reputed make/ already use in pdd), 33kv single tension disc fittings [3 bolts] suitable for dog conductor suitable for b&s 70kn disc insulators, 33kv pin insulators (porcelain) 70kn, 33kv g.i. pins (heavy duty), 11kv, 3 core cable kits [heat & shrinkable], a. indoor type, i) 600 mm. sq.single core, i. 400 mm sq., ii. 300 mm sq., iii. 240 mm sq, iv. 185 mm sq, b. outdoor type, i) 600 mm. sq.single core, i. 400 mm sq, ii. 300 mm sq, iii. 240 mm sq, iv. 185 mm sq, 11kv link set [heavy duty] 50*6 mm ( clamping suitable for dog conductor), 11kv l.a [station type]reputed make, 11kv l.a [line type] reputed make, guy wire 7/3.15mm, 33kv guy insulators, manila rope, i) 3/4 inch dia, ii) 1 inch dia, p.p.rope 3/4 dia, m.s. nut & bolts of sizes, i. 3" (full thread), ii. 6" (half thread), iii. 9" (half thread), iv. 10" (half thread), nuts and bolts brass, cork sheet 8mm, aluminum thimbles of sizes, i. 400mm sq, ii. 300mm sq, iii. 240mm sq, iv. 185mm sq, v. 120mm sq, drill bit [heavy duty], i. 16mm dia, ii. 19mm dia, iii.26mm dia, p.g clamps, i) suitable for panther conductor, ii) suitable for dog conductor, p.i clamps [suitable for dog conductor/panther], t clamps [suitable for dog conductor,panther ], brass bush rods of 33/11kv power transformer of sizes, i. hv [m20], ii. lv [m20], 33kv porcelain bushes of 33/11kv power transformer of sizes, i. hv side, ii. lv side, 3 core 11kv xlpe cable, i) 600 mm. sq., i. 400mm sq, ii. 300mm sq, iii. 240mm sq, iv. 185mm sq, v. 120mm sq, copper strip 20x3mm, vacuum interrupter suitable for, i. 11kv (yamuna] breaker, ii. 11kv [pascal] breaker, iii. 11kv (stelmec] breaker, iv. 11kv [schneider] breaker, iv. 11kv [electrifield make]breaker, aluminum bus bar 75x10mm, duck back shoes of different sizes, red oxide enamel paint (asian, nerolac/ berger), al. paint (asian, nerolac/ berger), 1.1kv voltage grade 2.5mm2 copper conductor, pvc insulated control cable conforming to is: 1554-1998, i. 2 core, ii. 4 core, iii. 5 core, iv) 8 core, iv. 10 core, v) 12core, 33kv current transformer of ratio, i. 750/375/5-5-5a, ii. 600/300/5-5-5a, iii. 400/200/5-5-5a, 33kv lightning arrestor [station type] reputed make, 33kv isolators with earthing blade, insulating hand gloves make crystal etc tested for 33kv level, aluminum ladder 9mtr long (folding), bamboo ladder 20 ft long, rubber mat 1mtr x2mtr, 12mm thick, 11kv operating rods, galvanised nuts and bolts of sorts, g.i wire 8 swg, lifting pulling machine 3 ton (make power ,wolf or any standard make), g.i earthing plates 2x2x6mm, pliers (taparia or any standard make), safety vest, safety belt, safety helmet (isi marked), 33kv danger plates complete, multimeter ( standard company make motwane , waco, etc), digital ampere meter [0-200/400 amps.], male contact (crompton greaves & emi make panel), female contact (crompton greaves & eim make panel), tripping coil suitable for 30/36v dc along with plunger for allind, bieco, make breaker, relays digital for vcbs for allind, bieco, easun,electricfield make panel, earth fault relay for vcb/ocb crompton greaves & emi make panel, over current relay for crompton greaves & emi make panel, 11kv ct set for breakers, i) 400-200/5 - 5amp, ii) 600-300/5 - 5amp, iii) 750-375/5 - 5amp, welding electrodes swg 8no as per is: 814 of 2004, maintenance free battery banks 36v ,vrla bank comprising of 18nos of cell [2 volt.100ah cell each] with tray and trolley of hbl,exide or any other reputed make, battery cells 2 volt,100ah(wet cell ) exide make, battery cells 2 volt,100ah (dry cell) exide make, master trip relay b24,110/125 v dc, guy rod complete with turn buckle, straining screws, guy plate etc [20mm] for 33 kv

CTN :40299809 Due date: 30 May, 202530 May, 2025 20.00 Lacs
Tender For rate contract for procurement of material in respect of std ganderbal for the year 2025-26 or till next stage contract is finalized - procurement of material in respect of std ganderbal for the year 2025-26 or till next stage contract is finalized, 11 kv horn gap fuse set 3 phase 200a, 11kv link rods for 11kv link set 22 feet long with insulating bottom grip bamboo/carbon fibre, gapless surge arrestor,9 kv ,10 ka ,la with polymer housing, stn. type, 11 kv isolator, double break,3-pole, 600amp, horizontal mounting type, with earth switch complete including clamps and fittings, 11 kv 3-core current transformer 800-400/5-5a,( metering, protection, differential core), 11 kv 3-core current transformer 750-375/5-5a,( metering, protection, differential core), 11 kv 3-core current transformer 600-300/5-5 a, ( metering, protection, differential core), 11 kv 2-core current transformer 600-300/5-5 a, ( metering, protection), 11 kv 2-core current transformer 400-200/5-5 a, ( metering, protection), 11 kv 2-core current transformer 100-50/5-5 a, ( metering, protection), 11 kv 2-core current transformer 50-25/5-5 a, ( metering, protection), 11 kv 2-core current transformer 20-10/5-5 a, ( metering, protection), 11 kv potential transformer 110v, accuracy class 0.5, tension fittings for 0.1 acsr conductor 70kn, tension fittings for 0.15 acsr conductor 70 kn, tension fittings for 0.2 acsr conductor 120 kn, 185 sqmm, 3core , 11 kv cable kit indoor type(make-3m/ polycab/ anchor/ havells/ gloster or equivalent), 185 sqmm, 3 core ,11 kv cable kit outdoor type(make-3m/ polycab/ anchor/ havells/ gloster or equivalent), 240 sqmm, 3 core,11 kv cable kit indoor type(make-3m/ polycab/ anchor/ havells/ gloster or equivalent), 240 sqmm, 3 core,11 kv cable kit outdoor type(make-3m/ polycab/ anchor/ havells/ gloster or equivalent), 300 sqmm, 3 core, 11 kv cable kit indoor type(make-3m/ polycab/ anchor/ havells/ gloster or equivalent), 300 sqmm, 3 core 11 kv cable kit outdoor type(make-3m/ polycab/ anchor/ havells/ gloster or equivalent), 400 sqmm, 3 core 11 kv cable kit indoor type(make-3m/ polycab/ anchor/ havells/ gloster or equivalent), 400 sqmm, 3 core 11 kv cable kit outdoor type(make-3m/ polycab/ anchor/ havells/ gloster or equivalent), 630 sqmm, single core 11 kv cable kit indoor type(make-3m/ polycab/ anchor/ havells/ gloster or equivalent), 630 sqmm, single core 11 kv cable kit outdoor type(make-3m/ polycab/ anchor/ havells/ gloster or equivalent), 185 sqmm, 11 kv 3 core xlpe cable armoured (make-3m/ polycab/ anchor/ havells/ gloster), 240 sqmm, 11 kv 3 core xlpe cable armoured (make-3m/ polycab/ anchor/ havells/ gloster), 300 sqmm, 11 kv 3 core xlpe cable armoured (make-3m/ polycab/ anchor/ havells/ gloster), 400 sqmm, 11 kv 3 core xlpe cable armoured (make-3m/ polycab/ anchor/ havells/ gloster), 120 sqmm, 3 core 33 kv cable kit outdoor type(make-3m/ polycab/ anchor/ havells/ gloster or equivalent), 300 sqmm, 3 core 33 kv cable kit outdoor type(make-3m/ polycab/ anchor/ havells/ gloster or equivalent), 400 sqmm, 3 core 33 kv cable kit outdoor type(make-3m/ polycab/ anchor/ havells/ gloster or equivalent), 120 sqmm, 33 kv 3 core xlpe cable(make-3m/ polycab/ anchor/ havells/ gloster), 300 sqmm, 33 kv 3 core xlpe cable(make-3m/ polycab/ anchor/ havells/ gloster), 400 sqmm, 33 kv 3 core xlpe cable(make-3m/ polycab/ anchor/ havells/ gloster), 11 kv 630 mm single core xlpe cable armoured, frls (make-3m/ polycab/ anchor/ havells/ gloster), tripping and closing coils must have burden between 250 to 350 watts at 30v dc with housing, tripping coil of 11kv alind make vcb, tripping coil of 11 kv er/vijai make vcb, tripping coil of 11kv electric field make vcb, tripping coil of 11kv abb make vcb, tripping coil of 11kv crompton make vcb, tripping coil of 11kv stelmac make vcb, tripping coil of 11kv sudhir/schneider make vcb, tripping coil of 11kv pascal make vcb, closing coil of 11kv alind make vcb, closing coil of 11 kv er/vijai make vcb, closing coil of 11kv el

Central Government And Public Sector

CTN :40291106 Due date: 30 May, 202530 May, 2025 NA
Tender For tender for supply of clamps and connectors - 33kv vcb to raccoon dog conduc clamp , suspension hardware for panther , single tension hardware for panther , t clamp acsr panther to panther , mid span clamp for acsr panther , 80 od al tube to ct pad clamp , ips al tube to ct pad clamp , rigid clamp for ct pad to acsr conductor , 220kv ct l clamp , t connector 2 5 ips al tube to moose , pg clamp for moose to zebra , t clamp acsr zebra run to moose
 Loading, Please wait...

Connect us via What's Up