Web Analytics Made Easy - StatCounter

Earth Terminal Tenders

Get complete information related to latest Earth Terminal Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Earth Terminal Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Earth Terminal Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :36225677 Due date: 11 Jun, 202411 Jun, 2024 NA
Tender For supply of de005544 ball joint , 3135j131 piston , pk4126x059 pipe assy , 3313t002 pin gudgeon , 5870200082 measuring cover , 130 005631 hyd sight guage , 5870058061 driver , 5870610005 insert , 5870105005 ribbon spnr , 5870200057 dial indicator , 36851123 joint lift pump , 99de1019 fuel pump pipe overflow , 350016 dowel , te01777 gauge speedometer , 33872532 hose , at151124 wiper arm , 265115100116 assy ce bracket , 252505167901 push rod , pk3114v041 pulley crank shaft , 21168022 dowel , 3681p009 joint , 2721a029 circlip , 25338624 fuel filter , 80179323 fuel filter 0 point 5 ltr dualpaper , 32100414 hose elbow , 461880300 valve exhaust , k40006 lock nut , 265115104904 earth terminal kit , 1420206001 ring sealing

CTN :36216087 Due date: 17 Jun, 202417 Jun, 2024 NA
Tender For supply, installation, testing & commissioning of set of indoor type vcb panel of 22 nos (06 nos i ncoming, 15 nos outgoing and 01 nos bus coupler) as per enclosed "cee/grc's specification no.- el/con/33 /11/6.6kv/6 kvvacuum-cb/1/2015", rated voltage 12kv, normal current 1250 amps, rated short circuit brea king current ( aginst clause 1.3 of annexure a of referred specification) shall be 40 ka. impulse test voltage (pea k) of 75kv and power frequency test voltage of 28kv (rms) shall be applicable in clause 1.6 of annexure a of ref erred specification. the enclosure shall provide at least the degree of protection ip 53. the oem's type test certif icate of switchgear for extended mechanical endurance class m2 and extended electrical endurance class e2 as per iec 62271-100 are to be furnished along with supply of materials. vcb panels shall be provided with a com mon bus bar set of 2 bars of size 100mmx12mm per phase. busbars will be made out of electrolytic copper of 9 9.9% purity. cts, pts and all other accessories shall be provided as per clause 4.2 to 4.4 of annexure a of referr ed specification. tri-vector meter, ammeter and voltmeter mentioned in clause 4.4 shall have digital display and shall be of modbus rs 485 port, accuracy class 0.5s as per is 15959 latest, power supply -230v ac. microproc essor based numerical protection relay, in addition to clause 4.4 & 6.2 under annexure-a, shall have 4 nos. selec table idmt curves for current-time characteristics. it shall have lcd display to display settings, trip records and also real time & date. it shall record 30 trip records with time and date & shall be provided with modbus rs485 po rt to communicate trip records and protection setting. battery charger and battery under clause 5.0 of annexure a of referred specification will not be required and is not covered under scope of supply. cable glands of stainles s steel are to be provided for all the cable entry holes, cable glands will be suitable for entry of cable and terminati on of armor of cable. cable entry for shall be from bottom only and for this- removable gland plate of thickness 3 mm (minimum) shall be provided as per drawing approval. 44 nos. of insulating mats of class b type conformin g to is 15652 latest, 1.5m (minimum) length & width are to be provided. 02 nos. earthing terminals are to be provi ded on each panel. all fasteners shall be of stainless steel. all meters, indication lamp shall have individual name plate on the front panel. necessary spares should be supplied as per attached annexure -c. the technical data sheet (annexure-b) must be submitted duly filled by the tenderers. work involves removal of existing sf6 & vc b panel including civil work as per annexure-ii. removed vcbs shall be shifted to place as directed by the consi gnee within 1 km. the price shall include transportation of vcb panel to the work site including all loadings and u nloadings without causing any damage of materials. designs/ drawings shall be submitted as per clause 5.1 to 5 .6 of referred specification and also the following for approval of dy.cee/ws /kgpws. a) technical data sheet b ) fully dimensional general arrangement drawing complete with plan, elevation and sectional views, location of ca ble entry for incoming and outgoing feeders. c) complete bill of material clearly indicating nos., rating, make, mod el no etc. of all components/ subassemblies/bought-outs etc. d) foundation drawing and cable entry details. e) s chematic wiring diagrams for all power, control, protection and indication circuits. f) manufacturers' catalogue/ tec hnical literature etc. for numerical relays and other bought-out items. tc & gc as per irs terms & conditions sh ould be supplied along with the material. [ warranty period: 30 months after the date of delivery ]

CTN :36197360 Due date: 19 Jun, 202419 Jun, 2024 NA
Tender For supply, installation, testing & commissioning of high mast solar lighting octagonal tower light as per mentioned specification:- (i) no. of integrated solar led street light (can be fitted in of each octagonal pole): 06 n os.(each capacity:50 watt), (ii) height of octagonal pole: 10 mtrs., (iii) earthing terminals on the base of the pole f or lighting and electrical protection, (iv) luminaries efficacy (limen/watt):> 100, (v) battery panel(ah): 51, (vi) ing ress protection: ip65,(vii) solar panel wattage:150 watt, (viii) system wattage:100 watt, (ix) thickness of octago nal pole sheet:03 mm, (x) thickness of base plate:16 mm, (xi) width of base plate:200 mm, (xii) length of base plate:200 mm. the details products specification as per annexure: [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up