Get complete information related to latest Earthing Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Earthing Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Earthing Conductor Tenders.
Tender For corrigendum : providing of custom bid for services - wiring for light pointfan pointexhaust fan pointcall bell point with 15 sqmm frls pvc insulated copper conductor single core cable in surface recessed pvc conduit with modular switch modular plate suitabl..,custom bid for services - wiring for submain wiring alongwith earth wire with the following sizes of pvc insulated copper conductor single core cable in surface recessed pvc conduit as required 2x25 sq mm 1x25 sq mm earth wire,custom bid for services - wiring for submain wiring alongwith earth wire with the following sizes of pvc insulated copper conductor single core cable in surface recessed pvc conduit as required 2 x 4 sqmm 1 x 4 sqmm earth wire,custom bid for services - wiring for submain wiring alongwith earth wire with the following sizes of pvc insulated copper conductor single core cable in surface recessed pvc conduit as required 2 x 6 sqmm 1 x 6 sqmm earth wire,custom bid for services - supply and fixing of following sizes of p
Tender For supply of sitc control panel 10 loops , sitc control panel 4 loops , sitc control panel 2 loops , sitc of network module. the module shall connect panels and repeator panel , sitc of active repeater panel to be integrated , sitc of addressable ip67 rated multi- heat sensor , sitc of analogue addressable photo thermal smoke detector , sitc of addressable multi sensor with co detection , sitcc of response indicator on surface , sitc of short circuit isolator module , sitc of analogue addressable dual action manual call point , sitc of addressable horn strobe with a maximum output , sitc of analogue addressable supervised monitor module , sitc of analogue addressable supervised control module , supplying and laying through walls, above false ceilin , dismantling of fire alarm and detection system , supply and fixing in replacement of earth continuity conductor , dismantling of old unsv control panel , demolition of wall and ceiling board , supply and fixing of suspended system ) /bid number : gem/2026/b/7339023 * /dated: 18-03-2026 & & / bid document 1 / 19
Tender For corrigendum : maintenance of electrical installation and fans including repair maintenance of ht substation, dg set, pump sets, ac units, external services, street lights etc at lab building ertl, akkulam, trivandrum. sh. interconnection of existing earth pits with copper earthingconductor.subwork/packages:single
Tender For corrigendum : supply of specified in srl no 19 of appendix a , s and f pvc connection pipe of 15 mm bore all as specified in srl no 20 of appendix a , s and f pvc flexible drain pipe of size 30 all as specified in srl no 21 of appendix a , cutting existing road hard standing with width not exceeding 750 mm and 1m deep all as specified in srl no 22 of appendix a , m and l for pcc type b1 using 20 mm graded stone aggregate all as specified in srl no 23 of appendix a , sitc of xlpe cable sizes 4 core 16 sqmm all as specified in srl no 24 of appendix a , m and l for excavation in trenches for cable laying all as specified in srl no 25 of appendix a , m and l for returning filling including spreading leveling watering in layers not exceeding 25 cm all as specified in srl no 26 of appendix a , m and l for removing excavated material all as specified in srl no 27 of appendix a , m and l for sand cushioning all as specified in srl no 28 of appendix a , m and labour for old size sub class b bricks laid in trenches all as specified in srl no 29 of appendix a , m and l for earthing with galvanized steel earth plate size 60cm 60cm 6mm thick all as specified in srl no 30 of appendix a , sitc of lt panel all as specified in srl no 31 of appendix a , sitc of deep freezer having hard top double door cap not less than 500 ltrs all as specified in srl no 32 of appendix a , m and l for point wiring with copper conductor cable 2 point 5sqmm all as specified in srl no 33 of appendix a , s and f switch socket 6a obliq 16a 5 in 1 flush type with gang box all as specified in srl no 34 of appendix a , sitc of inverter technology hot and cold split ac of cap 1 point 5 tr all as specified in srl no 35 of appendix a , s and f single pole and neutral steel metal enclosure with two pin and earth plug and socket with one single pole mcb of 32 amps , m and l for ac sub main wiring with 4 sqmm 1 core all as specified in srl no 36 of appendix a , s and f heavy duty copper pipe half inch dia all as specified in srl no 37 of appendix a , s and f heavy duty copper pipe 1 obliq 4 inch dia all as specified in srl no 38 of appendix a , s and f pvc drain pipes of suitable size 25 mm , sitc of inverter technology hot and cold split ac of cap 2 tr all as specified in srl no 39 of appendix a , m and l for ac sub main wiring with single core 6 sqmm all as specified in srl no 40 of appendix a , s and f heavy duty copper pipe of size 15mm all as specified in srl no 41 of appendix a , s and f heavy duty copper pipe of size 10mm all as specified in srl no 42 of appendix a , automatic line voltage correctors (step type) for domestic use (stabilizer) conforming to is 8448 (q2)
Tender For supply of insulated flexible copper conductoras required dot , supplylaying testing and commissioning of aluminiumslashcopper conductor cable pvcinsulated armouredpvc sheathed 1100 volts grade doton surface the cable run shall be fixed by gi , supplylaying testing and commissioning of aluminiumslashcopper conductor cable pvcinsulated armouredpvc sheathed 1100 volts grade doton surface the cable run shall be fixed by gi clamps , supplylaying testing and commissioning of aluminiumslashcopper conductor cable pvcinsulated armouredpvc sheathed 1100 volts grade doton surface the cable run shall be fixed by gi clamps etc dotof , supplying and laying of following size dwc hdpe pipe isi marked along with all accessories , supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socketbendcouplers etc dotconforming to is 14930part ii complete with fitting , supply and fixing offollowingsizes of pvc conduit along with accessories in surface slash recess including cuttingthe wall and making good the same in case of recessed conduit , supply and fixing offollowingsizes of pvc conduit along with accessories in surface slash recess including cuttingthe wall , earthing with g dot i dotearth plate 600 mm x 600 mm x 6 mmthick including accessoriesand providing masonry enclosure with cover plate having , supplying and laying 25 mm x 5 mm g dot i strip at 0 dot 50 metre below ground as strip earth electrodeincluding connectionslashterminating with , providing and fixing 25 mm x 5 mm g dot i dot strip in 40 mm dia g dot i dot pipe from earth electrode including connection with g dot i dotnutboltspringwasher , providing and fixing 25 mm x 5 mm gistrip on surface or in recess for connections etc dotas required dot , providing and fixing 6 swg dia gi wire on surface or in recess for loop earthing as required dot , construction of man hyphenhole with 9 brick workand rcc top cover 2 dot 5ft x 2 dot 5ftto enclose the masonry enclosure of earthing pit atleast 1 dot 5ft deep from ground level , supplying and fixing of led street lightslashflood light luminaire with system efficacy of 100 lumens slash watt with pdc housinghigh impact resistance ik07glass cover for lighting
Tender For supply of design comma manufacture commasupply comma installation commatestingandcommissioning customized subdistribution panel commacubical type sheet steel clad ip52 comma , supply commalaying and installation of pvc insulated and pvc sheathedslashxlpe alluminium power cable of 1 dot 1 kv grade of following size indcw hdpeslashpvc conduit pipe , supplying and making indoor end termination with brass compression gland and aluminum lugs for following size of pvc insulated and pvc sheathed aluminum conductor cable , making holes on brick walls of 100 mm dia approximately fro crossing pipes and making it good dot , supplyingandlaying ofpvc insulated and pvc sheathed flexible copper power cable of 1 dot 1 kv grade of following size on surfaces as required 6 sq dotmm 3 core , supplying and fixing of following sizes of pvc conduit along with accessories in surfaceslashrecess including cutting the wall and making good the same in case of recessed conduit as , supplying and fixing of following sizes of pvc conduit along with accessories in surfaceslashrecess including cutting the wall and making good the same in case of recessed conduit , supplying comma installationtesting and commissioning of customized subdistribution meter panel commacubical type sheet steel clad ip52 commacompartmentalized , earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories commaand providing masonry enclosure with cover plate having locking arrangement , providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc dotas required dot , providing and fixing 4 dot 00 mm dia copper wire on surface or in recess for loop earthing as required dot , supplying and drawing of utp 4 pair cat 6 lan cable in the existing surface slashrecessed steel slashpvc conduit as required dotd hyphenlink commaschn , supplying and drawing of utp 4 pair cat 6 lan cable in the existing surface slashrecessed steel slashpvc conduit as required dotd hyphenlink commaschneider , supplying and installing of following size of hot dipped galvanised perforated iron tray galvanisation thickness not less than 50 microns with perforation not more , supplying and installing of following size of perforated hot dipped galvanisediron trayinchbendsinch galvanisation not less than 50 microns with perforation not more than 17 , making padestalslashcoloumn supports comma9inch x 9inch using gi angleslashpipe for cable trays dot , shifting of outdoor ac units dismantling and refixing slash instaling at new location commaincluding topup of gas complete job as required as per site requirements dot , supply of following accessories for split airconditionersstand for o slash d unitwall mounting , supply of following accessories for split airconditionerscopper pipingmain and returnrecessedslashon surface as required including repairing of the walls , supply of following accessories for split airconditionerselectric wiring 2 dot 5 sq mm 4 core recessedslashon surface as required including repairing of the walls , supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket commabend commacouplers etc dotconforming to is 14930 , providing and fixing box type commawall mountable commashutter enclosure for outdoor solar inverter and other electrical system made out of 14 gauge powder //bid details 2 / 22
Tender For supply of supply and laying of xlpe al cable 3c 5x185sqmm : : -mcb/mccb, xlpe insulated aluminum conductor power cable, pvc insulated copper cable, dwc hdpe pipe, gi earth ριρε, any other material
Tender For bid to ras supply of split air conditioner, wall mount type (v3) isi marked to is 1391 (part 2) (q2) , automatic line voltage correctors (step type) for domestic use (stabilizer) conforming to is 8448 (q2) , m and l for concealed point wiring complete with 4 sq mm frls, pvc insulated multi standard copper conductor single core cable 1100 volts grade , m and l for concealed point wiring complete with 2. 5 sq mm frls, pvc insulated multi standard copper conductor single core cable 1100 volts grade, drawn into non metalic , supply and fix single pole and neutral enclosure 240 volt, 20 amps with a two pin and earth plug and socket complete with one single pole mcb , m and l cutting chases, pinning in making good to facing where required and pointing in cement mortar 1 by 3 to ends or edges of landings, steps, cils , supply and fix refrigrator, electric driven single phase, capacity upto 195 litres. bee 5 star rated all as specified and as directed , supply and install wall bracket-ac stand heavy duty for fixing of outdoor unit of split ac all as specified and as directed
Tender For maintenance of electrical installation and fans including repair maintenance of ht substation, dg set, pump sets, ac units, external services, street lights etc at lab building ertl, akkulam, trivandrum. sh. interconnection of existing earth pits, with copper earthingconductorsubwork/packages:single