Get complete information related to latest Electric Crane Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electric Crane Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electric Crane Tenders.
Tender For corrigendum : daiviya apda work under edsd- rura - carriage of various size pcc poles from store center or from any other place to the respective site of work distence up to 75 km through the kachha pacca road including the work of its loading & unloading at the respective ends also including the work of its dragging etc. and also including the cost of labour, t & p and carrier etc. required for proper completion of work., carriage of various size st poles (9 mtr /11mtr/ 13mtr ) from store center or from any other place to the respective site of work distence up to 75 km through the kachha pacca road including the work of its loading & unloading at the respective ends also including the work of its dragging etc. and also including the cost of labour, t & p and carrier etc. required for proper completion of work., carriage of line material viz. weasel/rabbit/racoon /dog conductor, g.i. earth wire, cross arm, angle, channel, cable boxes, static meter insulators, clamps and other line material from store center or from any other place to the respective site of work through the kachha pacca road including the work of its loading & unloading at the respective ends also including the work of its dragging etc. and also including the cost of labour, t & p and carrier etc. required for proper completion of work., erection of p.c.c double pole including the work of complete h.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t & p and carrier etc. required for proper completion of work., grouting of p.c.c double pole the support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement., erection of p.c.c single pole including the work of complete h.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t & p and carrier etc. required for proper completion of work., grouting of p.c.c single pole. the support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement., erection of s.t.p single pole including the work of complete h.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t & p and carrier etc. required for proper completion of work., grouting of s.t.p single pole. the support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement., erection of s.t.p double pole including the work of complete h.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t & p and carrier etc. required for proper completion of work., grouting of s.t.p double pole. the support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement., renozzling of damaged stay set as per respo manual and also including the cost of all grouting material, labour, t & p etc. required for proper completion of work., dismentling of rusted weasal/racoon /dog conductor wire and g.i wire & safe carriage of scrap material back to store as per respo manual and as per direction of supervising engineer. it includes the cost of labour, t & p, carries etc. required for proper completion of work., laying, sagging, stringing, binding and jumpering etc. of weasal/dog/rabbit conductor in new erected pole as per respo manual and as per direction of supervising engineer. it includes the cost of labour, t & p, carries etc. required for prope
Tender For m and r work under edd- rania -- loading 8.5 m long pcc pole from electricity storage centre jainpur on own vehicle and taking it to work site and unloading it safely through unpaved road. a loading 11 m stp pole from electricity storage centre jainpur on own vehicle and taking it to work site and unloading it safely through unpaved road. a transport of electric line material like conductor, clamp, nut-bolt wire, lt cable, stonepad, station set, xlpe, abc etc. to the specified place by own vehicle for an estimated distance of 75 km through unpaved road. a digging pit at the place of broken/damaged poles and installing pcc poles by tying all accessories like cross arm, disc, pin insulator etc. and fitting earthing rod. a tying all accessories as per requirement in the long span in the middle of the already constructed line. the work of re-energizing by installing additional pcc/stp poles as per the prescribed standard/specification of response link. a the work of re-energizing by installing additional pcc/stp poles as per the prescribed standard/specification of response link while tying all the accessories as per requirement in the middle long span of the already constructed line. a installation of new section double pole in place of broken/damaged double pole. a grouting work of pcc/stp poles as per respo standard. supplying cement, ballast, gravel in the ratio of 1:2:4. repairing section double pole. tightening damaged stays by renosing. tightening the white wires of 33 kv line, each wire and tightening the white wires of lt and 11 kv line, each wire. straightening the skewed poles of 33 kv line/11 kv line/lt line as per respo standard and tying all accessories and erecting them correctly. giving clearance by trimming the trees of 33/11 kv and lt line. spreading the acsr vessel conductor in 33/11 kv line and tying stringing and sagging insulators in all the three phases and jumpering and earthing each wire. replacing damaged cross arm.send feedbackside panelshistorysaved
Tender For deposite work under edsd- rania - carriage of following material from store center or from any other place to the respective site of work distence up to 75 km through the kachha pacca road including the work of its loading & unloading at the respective ends also including the work of its dragging etc. and also including the cost of labour, t & p and carrier etc. required for proper completion of work., 8.5 mtr pcc pole, 11 mtr stp, different line material ( conductor, x-arm,channel, insulator , g.i. wire , stay wire & rod, earth rod , db box etc.), different capacity dt( 100/63/25/16/10 kva ), pilfer unit , ct/pt double metering unit ., erection of following material :, x-arm holding clamp / holding clamp with n&b, f- clamp with n&b, i/d & o/d type cable jointing kit suitable for 11 kv xlpe cable ( different size), stay insulator, g.i. pipe 6" dia, stone pad, anti climbing device as per respo norms ( with barbed wire ), danger board as per respo norms., erection of following material including the work of complete h.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t & p and carrier etc. required for proper completion of work. (with proper earthing.), single pole structure of 8.5 mtr pcc pole, single pole structure of 11 mtr stp pole, double pole structure of 8.5 mtr pcc pole, double pole structure of 11 mtr stp pole, stay set, laying of 11 kv xlpe cable (different size ) as per respo manual and as per direction of je inchrge., laying of 11 kv xlpe cable (different size ) inside g.i. pipe ., laying, sagging, stringing, binding and jumpering etc. of weasal/racoon /dog conductor on the newly erected pole/ old pole as per respo manual and as per direction of supervising engineer. it includes the cost of labour, t & p, carries etc. required for proper completion of work., grouting of pole as per respo norms ( cement, sand , blast stone with the ration 1:4:8 will be provided by contractor ), grouting of stay set( cement, sand , blast stone with the ration 1:4:8 will be provided by contractor ), muffing of s.t.p. as per respo norms ( require material will be provided by contractor ), dismantling of existing 33kv/11 kv / l.t. line and removal of all accessories & fittings from poles, re-rolling of conductor and proper stacking and cartage of dismantled conductor & accessories from site of work to dvvnl, store., making joint with the help of cable jointing kiit (11 kv ), mounting of d.t. (100/63/25/16/10 kva ) upon double pole as per respo manual., installation of ct/pt unit as per respo manual., installation & grouting of pilfer unit as per respo manual., cutting of tree branches for clearness of line.
Tender For 10/edc(s)/2025-26 - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grouted on all 04 corners and 01 side for gate.
Tender For runningcontractfordepositworksunderedd-lambhua,sultanpur. - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grouted
Tender For runningcontractfordepositworksunderedd-baldirai,sultanpur. - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grouted
Tender For runningcontractfordepositworksunderedd-jaisinghpur,sultanpur. - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grou
Tender For runningcontractfordepositworksunderedd,sultanpur. - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grouted on all 0
Tender For corrigendum : works related to storm/cyclone (natural calamity) within the limits of v.v.khan., banda (city). - the work of special maintenance and repairing of 11 kv ht and lt damaged lines of various places under various 33/11 kv sub-stations due to heavy storm under daiviya apada/o&m year 2025-26 under edd, banda (town), including carriage of all required material from esc banda to work site, alongwith its loading, unloading & dragging at the respective ends and also safe carriage of old line material/scraped from site to store centre. the bidder shall be responsible for complete execution of the work under the scope of tender specification. any work/activity not specifically indicated but is required for systematic execution of job shall be carried out by the contractor without any extra payment. the material supplied by contractor should be the best quality and as per standard including transportation, if any. details of the work as given below ;-, safe cartage of 8.5 mtr. long pcc poles, safe cartage of 11 mtr. long st poles, safe cartage of line material, erection of newly erected 8.5 mtr. long pcc poles as single support structure, including complete ht/lt fittings as per direction of engineer incharge/resspo manual., erection of newly erected 11 mtr. long st poles as single pole structure, including complete ht/lt fittings as per direction of engineer incharge/resspo manual., erection of newly erected 8.5 mtr. long pcc poles as double pole structure, including complete ht/lt fittings as per direction of engineer incharge/resspo manual., erection of newly erected 11 mtr. long st poles as double pole structure, including complete ht/lt fittings as per direction of engineer incharge/resspo manual., concreting/grouting of newly erected 8.5 mtr. long pcc poles as single support/double pole structures. the support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 cu. mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement & direction of enginner incharge., concreting/grouting of newly erected 11 mtr. long st poles as single support/double pole structures. the support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 cu. mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement & direction of enginner incharge., erection and grouting of stay set including the work of nozelling etc. as per resspo manual and also including the cost of all grouting material., fixing of earthing rod as per direction of supervising engineer/resspo manual. including the cost of labour, t&p etc. required for proper completion of work., laying, sagging, stringing, binding and jumpering of new acsr weasel conductor on the erected poles in 11 kv ht/lt lines also providing in-place of damaged/misplace conductor due to heavy storm., laying, stringing, binding and termination etc. of abc cable of various size on the erected poles as per direction of supervising engineer/resspo manual., re-sagging of loose conductor of 11 kv ht lines at various places., re-sagging of loose conductor of lt lines at various places., dismentling & removal of existing/erected old & damaged pcc/stp/joist/rail poles as single pole structure with its accessories., dismentling & removal of existing/erected old & damaged pcc/stp/joist/rail poles as double pole structure with its accessories., carriage of damaged/rusted st/rail/joist poles from work site to esc., replacement of damaged/misplace "v" type cross arm, guarding with fitting of all accessories as per resspo manual., dismentling & removal of damaged weasel conductor with its accessories due to heavy storm and also cartage of old/damaged & scrap line material from work site to store centre/je(s)., straightening of tilted single support as 8.5/1
Tender For e-tender (2nd call) for procurement of laboratory instruments, equipment, appliances for the college of veterinary sciences and ah, rk nagar under the nec funded project for the year 2025-2026 - biosafety cabinetclassii, a 2 with accessories and power back up (bacteriology)-- the biological safety cabinet should be of class ii, type a2 designed in compliance with international standards the biological safety cabinet quoted instrument model must have international standards test likensf, tuv nord, en 12469 certification. certificate copy must be provided along with the technical bid. working area should be around 4foot. it should have exterior dimension w x h x d of 1300x 1568 x 800 and interior dimension wxhxdof 1200x 780x 630 it should have 1 piece grade 304 stainless steel or thermos scientific smart coat interior itshouldhavefeatureforpersonalprotection,sample protection, cross contamination protection and environmental protection. it must utilize brushless dc motor technology which uses significantly less energy with less heat emission provision compared to traditional ac motor technology to ensure lower levels of energy consumption. it should have 10 sloped front for exceptional comfort and ergonomics thesystemshouldbedesignedwithdualmotor. the motor must automatically adjust or control fan speed in real time to maintain constant airflow during filter loading or temporary obstruction. air flow direction: vertical laminar flow & air intake across front opening and 70% recirculation. filter: high performance particle air filter h14(hepa en1822), filtering efficiency 99.995% mpps or better. energy saving mode when cabinet not in use with maintaining sterility. continuous airflow helps to maintaina sterile environment, evenwhen the cabinet is not in use. thesystemshouldhaveindependentsensorstodetect pressure changes across the exhaust and down flow plenum/ air velocity and should indicate alarm signal when a 20-30% change in inflow/ exhaust or down flow occurs. control panel and performance monitor displays inflow/ down flow velocities, hours of use etc. to verify proper cabinet operation. frontglasswindowshouldbeeasilyloweredfor thorough smart cleaning of inner surfaces and designed to protect users by maintaining inflow, even when the window is lowered. the uv light must be quoted which should be programmable from 30 min to 24 hrs. in minimum 30 minutes increment to shut off automatically. the settings must allow the user to program the timer. the cabinet noise level must be less than 63 db(a) as measured in a sound proof room to promote more comfortable and safer working habitsof the user a per nsf/ ansi 49. the controller must be located on a slanted frontpanel so it is easy to see from a seated working position in front of the cabinet. control panel should be a large digital color touch screen display with health monitoring system, valuable safety and performance data with constant read-out of downflow/ inflow velocities and hours of operation in real-time, number of hours of use on the hepa filters. the front window sash must be angled 10 sloped front for operator comfort. two pieces of removable and autoclavable stainless steel arm rest should be provided for operator s comfort without disturbing the air flow. the system must have audio visual alarms to indicate when inflow is restricted and as well as whether front window is in correct position or not. theworkareashouldbeilluminatedwithswitchable fluorescent lamp of lighting power >120 fc or higher. suitable height floor stand without casters should be provided. in built access ports, 2 nos. (1 on each side) shouldbe available. it has single piece stainless steel work tray for easy cleaning and decontamination. warranty:minimum3year. electrical supply available: 230v a.c, single phase, 50 hz. bidder should provide printed brochure of the quoted model and details specification should be available in the manufacture website. customized model would not be accepted wi