Tender For corrigendum : supply of 11kv and 33 kv outdoor oil cooled metering unit (combined ct and pt set) under south andaman division sub-division - supply of 11kv & 33 kv outdoor oil cooled metering unit (combined ct & pt set) under south andaman division sub-division., 11kv outdoor oil cooled ctpt combined unit 50hz three phase six bushing typewith three no. ct and one no. three phase vtwith hv neutral broughtout andearthed ilv 12/28/75 kvp ins class a, ref std refstd is16227- 1&4ct specification:ratio 80-40/5a class 0.5 burden 15va isf=7.5@ 40a stc 4ka time: 1 sec.vt specification:ratio 11kv/110v class 0.5 burden 100va voltagefactor 1.2 continuous/1.5 for 30 seconds vectorgroup/connection star/star (ynyn0). terminals: brass stud typeprimary terminals m12 in size with nut, plainwasher, spring washer & check nut. withoutterminal connector. minimum creepage distance25mm/kv.note :primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50hz three phase six bushing type with three nosct and single nos three phase vt with hvneutral brought out and earthed ilv 36/70/170 kvpins class a ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4ka time :1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 secondsvector group/connection star/star (ynyn0).terminals:terminals: brass stud type primary terminalsm12 with nut, plain washer, spring washer &check nut. without terminal connector. minimumcreepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50hz three phase three bushing three nos. ctsand one no. three phase vt with hv neutralbroughtout and earthed. ilv 36/70/170 kvp insclass a , ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4 ka time : 1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 seconds.vector group/connection star/starterminals:brass stud type primary terminals m12 with nut,plain washer, spring washer & check nut.without terminal connector.minimum creepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50 hz three phase three bushing three nos. ctsand one no. three phase vt with hv neutralbroughtout and earthed. ilv 36/70/170 kvp insclass a , ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4 ka time : 1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 seconds.vector group/connection star/starterminals:brass stud type primary terminals m12 with nut,plain washer, spring washer & check nut.without terminal connector.minimum creepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., transportation, transit,insurance, packagingcharges
Tender For corrigendum : appointment of advanced metering infrastructure (ami) service provider for smart prepaid metering on dbfoot basis through e-reverse auction mode only- for gwalior region
Tender For corrigendum : appointment of advanced metering infrastructure (ami) service provider for smart prepaid metering on dbfoot basis through e-reverse auction mode only
Tender For work of monthly meter reading work through cmri/mobile app and bill printing/bill distribution in respect of solar net metering consumers, commercial and industrial consumers having load above 20 kw and some lt consumers having load below 20 kw with amr /mri compatible meters under various sub divisions under nashik circle.
Tender For supply of pvdg metering arrangement for tariff conversion from commercial to industrial at cto compound ngp : : -sitc of wall mounted mv panel having 1 no 250 a 4 pole mccb as incomer and 2 nos 125 a and 1 no 160 a 4 pole mccbs for outgoings , supply and installation of 1 no trivector energy meter class 0. 5s model er300p base mounting , laying and fixing of one number above 95 sq. mm and upto 185 sq. mm size cable in the existing masonry open duct , laying and fixing of one number above 95 sq. mm and upto 185 sq. mm size cable on wall surface , p and f 6 swg dia gi wire along with existing surface or recessed conduit or submain wiring or cable , charges for shifting of existing lt cable from old panel to the new panel
Tender For tender for p/s for replacment of power cable for dt metering at various location under sankara d/c under & renovation of distribution transformer 06 no. 10kva 16 sqmm single core cable for dt metering at various location & for renovation of distribution transformer 01 no. 100 kva 150 sqmm single core cable for dt metering at various location under sankara d/c & for renovation of distribution transformer 01 no. 200kva 300 sqmm single core cable for dt metering at various location under sankara d/c under nagri sub. dn. under o&m cspdcl dhamtari. . (only scheme for 028 scheme)
Tender For design, engineering, supply, installation, testing, commissioning, synchronizing with the grid of grid connected solar tree solar pv systems on capex model net metering basis on the fabricated tree structure of identified locations with comprehensive maintenance of same for 5(five) years including defect liability period of 5 years.