Tender For supply of energy harvesting development kit (item name) energy harvesting power management evaluation boardenergy harvesting power management evaluation board, mini solar panel, thermoelectric generator (teg) module, piezo / vibration energy harvester, supercapacitor, low-power microcontroller board, voltage / current monitoring module, resistive load / dummy load module, prototyping / breakout board, connecting cables & headers, enclosure / mounting hardware
Tender For supply of 5 kva online ups , battery bank for ups 26ah 12v , ats switch for ups , battery bank rack for ups batteries , class c or type ii single phase surge protection device , float cum boost charger 24 volt 30 ampere , battery bank for vhf radios 150 ah 12v , battery bank rack for vhf radios , ac power cable , 16 a socket , modular board , 16 a switch , mcb , pvc pipe for laying power ac cable along with wall clamps , miscellaneous item , supply installation testing and commissioning of item 1 to 15 above and training
Tender For corrigendum : supply of item for procurement : led lights - specification of led lights :-input voltage : 250v ac, ( 5%) operating volt. range -100v 285v ac., input frequency :- 50 hz ( 3%hz), usage hours 24x7x365 per year, power factor :- > 0.9, no. of leds - as per design by party. colour temperature ( k) - 5500-6500 or white or warm white, luminous efficacy in lumens per watt : - > 100 or more, led operational life :- > 50000 burning hrs., lumen maintenance - 70% over 50,000 hrs., working humidity :- 10% to 90% rh, working temperature :- 5 to 50 c, ingress protection - ip65, colour rendering index (cri): - > 80, driver type - constant current type, total energy consumption of the system :- 1.15 times rated wattage, applicable standards/mandatory requirement - the fixture should conform to applicable ies/iesna lm79-80/iec equivalent indian standard : is 16106-2011) note : 1. wattage, model and make of the fixture should be same as accepted techno - commercially. 2. lm-79-80 certificate copy along with the supply., cat. no. 00006359400 40w, led light complete with well glass fittings sets including luminaries., cat. no. 00006359700120w, led flood light fittings including luminaries
Tender For improvement of internal and external electrification system and allied works at water gallery sarita vihar ht bps under okhla constituency ac-54. - providing of new generation energy saving and environmentally friendly long life of 70/72 watt led street light made up of pressure die cast aluminium hosing with high efficient led as lighting source and pc cover having top opening separate driver compartment with ip66 protection and impact resistance of 1k07. make:-havells/ bajaj/crompton/phillips/wipro., supplying and fixing of 32 mm dia. x 2.00 mtr. long g.i. pipe(medium class) bracket for mounting of fluorescent / hpmv /hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required., supply of pole mounted cable junction box of size 350x250x138 having ip 65 protection with complete accessories as per site requirement .make:- sintex/ hensel, supply of 2 x 10 sq. mm. aluminium conductor power armoured cable. make :- gloster/ grandly/ universal/ havells/cci /djb approved., laying and fixing of one number pvc insulated and pvc sheathed/ xlpe power cable of 1.1 kv grade of following size on wall surface as reqd. (clamped with 1mm thick saddle) 2x 10 sq. mm., fixing of control junction box with the help of nut, bolts, washers, fasteners etc. as per site requirement. ( 10% of sn.3), providing of decorative ultra slim square profile led lighting fixture with extruded polycarbonate, environmental friendly energy efficient ready to use pack. led tube light of 20 watt 6000k. make: havells /bajaj/ philips/crompton/ wipro., providing of heavy duty exhaust fan of size 450 mm, 1440 r.p.m of single phase 230 volt. make: havells /bajaj/ philips/crompton/ usha/ khaitan/ almonard., installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required., providing of ceiling fan 1200 mm sweep. make: orient/havells /bajaj/ philips/crompton/ usha/ khaitan/ almonard., installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable etc. as required., providing of air circulator 600 mm sweep. make: orient/havells /bajaj/ philips/crompton/ usha/ khaitan/ almonard., installation, testing and commissioning of air circulator, including wiring with 2.5 sq. mm frls pvc insulated, copper conductor, single core. cable etc. as required. ( 10% of sn.13), wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c, dsr (e&m)2024-25, item code - 1.10.3, wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit along with 1 no 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. dsr (e&m)2024-25, item code - 1.12, wiring for circuit/ sub-main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 x 2.5 sq. mm +1 x 2.5 sq. mm earth wire. dsr (e&m)2024-25, item code - 1.14.2, supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required. dsr (e&m)2024-25, item no.- 1.31, supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6
Tender For procurement of spares of analyzer system installed at ktps kota - thimble filter u shaped length:- ioo mm x 1d:-25mm spare ofcems filteration capacity 10 microns or bener, condensate monitoring relay 24vdc, model no:- kfd2-srz exl.wlb or better, condensate monitor moisture sensor/detector alongwith 0 ring compatible for item no. 3 or better, disposable fi lter cartidge filteration size:-o.i micron. dia:- 28mm length:- 800101, tllickness: -20101 , width:-28m01 material :- fiber medium:- air or bener, smps power supply abl 2rem 24045k input 100-240 v ac/, output 24 vdc/ 4.5a schnieder or benei', sample line solenoid valve 2 way make:- rotex. 20 i 0 1-2.5-2r-b5 body material ss media:- air atm:- 0-1 2 or better, sample line solenoid valve 3 way make:- rotex model:-3030 1-1.2-2r-b5 or better, gas cooler model:- sgc-2302 set temp:-5deg power supply 230v ac , 50hz or better, peristaltic pump with i meter tube make: thomas model:sr2s flow capacity: -0.9lph pressure: -o.i bar supply 230v ac,sohz or better, sample pump (knf) type:n86kte, capacity-9.s lpm power:-0 .06kw pm3'(=2.5 bar, 230vac, 50hz, amp:-0.6sa or better, timer for soxino" analyzer make: selec 80 xc cyclic timer with unequal on & off time 6 time ranges, universal supply voltage led indications : power on, relay on features : finger safe terminals certificatio n:ce or better, network switch port:8 (eight 10/ 100 fast ethernet lan ports) advanced features: - 1.6 gbps switching fabric -i eee 802.3x flow control , - supports 2048-byte jumbo frames led indicators : per port: link! activity, per device: power, power: 5 v/o.55 a power adapter or better, exide 12v,18ah battery or equivalent, online ups for etp system with insta llation tech. specs: i kva 24v with in-bu ilt batteries (12 v 9 ah x 2) input voltage range: i iovac±5% - 300 vac ±5% output voltage: 2001208/220/230/240 vac or equivalent, 18 ah battery buyback price p&f charges if any , if extra, please indicate applicable rate is p&f charges. gst , if extra or inclusive than applicable rate of gst. , freight charges (on freight paid basis, as per gcc) , if extra, please indicate applicable rate of freight charges , transit insurance charges (as per gcc) , if extra, than please indicate applicable rate of transit insurance charges. , other charges (if any)
Tender For supply of e4953112 for networking items for solar power project ntpc vindhyachal : : -e4953112 networking items 01-sg4950267000-lan based gps clock with antenna cable as per ann-a item-01 uom-set , 02-sg4950267108-online ups system as per ann-a item-02 uom-set , 03-sg4950267116-lc-lc connector type patch cord as per ann-a item-03 , 4- not to quote , 5-not to quote
Tender For conversion of overhead line into underground cable (ug cable) in the existing 2 nos of 11 kv urban feeders to provide uninterrupted power supply, enhancing safety & avoid accidents in tiptur town, tiptur sub-division, tiptur division, bescom on total turnkey basis under item wise fixed price contract on percentage quoting basis.
Tender For tender for supply of sitc of air conditioner : : -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1391 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters auto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply. the indoor unit shall be suspended from the ceiling using threaded rods- including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required. , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealedscrollrotary compressor and eco friendly refrigerantinitial charge of refrigerantcondensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply. the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floorlaying and interconnection of standard-length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required. necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no. 1 2 , supply laying of 4c x 2.5 sqmm frls pvc insulated 1.1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1.2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required. , supply and fixing of 75mm dia minimum 1.8mm thickness pvc covering pipe using necessary bend collor clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25x25x5mm l angle frame including clamps bolts nuts vibrating dampers as required for mounting of outdoor unit. , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar to match for the surrounding as required after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling.
Tender For supply of item id: 3100525 ,weld trimmer power pack version for at welding as per rdso specification no. tm/sm/9 date: 16.08.1991 (second rivision 2022)