Get complete information related to latest Electrical Breaker Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electrical Breaker Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electrical Breaker Tenders.
Tender For corrigendum : supply of 36 kv outdoor vcb, 2000 amp, isc-31.5ka for 3 sec, coil voltage-220v dc with all accessories , 36 kv, 2000 a, 3 phase vacuum circuit breaker without terminal connector with coil voltage-48 v (dc)
Tender For "mccb,800a 3-pole, moulded case circuit breaker,rated voltage 415v, rated current 800a, 3ph, 50hz of minimum 35 ka rupturing capacity at 415v 50 hz ac with therm al and magnetic o/l. the thermal o/l setting shall be variable covering a minimum range of 650 to 800 a. the mccb shall be confirming to latest is: 60947 authorised dealers/ma nufacturers to quote. warranty: 12 months from the date of commissioning or 18 mon ths from the date of supply". [ warranty period: 12 months after the date of delivery ]
Tender For supply of miniature circuit breaker as per technical description - no. of poles- 02 poles, operating voltage - 12-500v dc, rated current - 3a, rated insulation voltage - 500v dc, mounting mode - clip 'on ', mounting support - din rail make/brand - schneider model no. c60h - dc 2 pole 3a or exactly equival ent. [ warranty period: 30 months after the date of delivery ]
Tender For supply of 100 a protected poles: 4 pole, 18 ka mccb, rated current (in)100a , user value rated opera tional voltage (ue ):415v / 440v ac, rated insulation voltage (uj ):440v ac, rated impulse withstand volta ge (uimp):5 ,kv, rated frequency:50 hz, rated short-circuit capacity (lcn):18 ka, instantaneous tripping cur rent: c-type, each circuit-breaker shall be marked as per is 60947.2.2003, protection type - l for overload p rotection (thermal) & i for short-circuit protection (magnetic), adjustable thermal-magnetic trip and protecti on unit, fixed magnetic settings and with toggle control. [ warranty period: 30 months after the date of d elivery ]
Tender For corrigendum : procurement of spares of mineline private limited make flp vcb 3 3kv flp tsu 3 3kv 550v flp acb etc - isolator 400a , vacuum circuit breaker 3.3kv , potential transformer 3.3 kv , hrc ht pt fuse , primary side p.t fuse plate wiring assembly , h.t. control plate wiring assembly , voltmeter , fuse terminal , multicore bushing , indicating lamp , 3.3kv adopter , 3.3kv coupler , bullet pin 3.3kv , hv bushing , dc power pack , neutral monitoring relay with resistance , earth leakage 50 750m a and 750ma 2a dual settings , earth leakage relay 50 750m a with time lag with cbct , overload short circuit and motor protection relay , vcb aux .rotary switch , control relay , ht bushing , vcb shunt trip coil , timer , 3 pole oil dashpot relay , cover bolts , insulator assembly k3 on off , overload assembly breaker 110a 200a , overload assembly breaker 310a 400a , overload coil 200a , short trip assembly complete , shunt trip coils , no volt coil assy. under voltage coil assy. with moulding , catcher assembly , arc chutes , ammeter 200 5 for acb , ammeter 100 5 for acb , ammeter 300 5 for acb , ammeter 400 5 for acb , busbar , potential transformer , brass cone and gland assembly , indicating lamps , power cable for 300a for breaker chamber ic and og , limit switch 2no 2nc for breaker , brass terminal for cp , brass terminal with dmc insulator , terminal bushing insulator dmc incoming 10mmx25mm , on off isolator 300a , split type terminal box , on off isolator 400a , circuit breaker for 100a with complete assy. , circuit breaker for 200a with complete assy. , complete control wiring including pla relay ptds elm7 control fuses control plate wiring harness etc mounted on control plate or circuit breaker for 300a with complete assy , complete control wiring including pla relay ptds elm7 control fuses control plate wiring harness etc mounted on control plate or circuit breaker for 400a with complete assy , earth leakage 50 750m a with time lag , core balance transformer , on off isolator 100a , isolator handle , 1ph 5kva lighting transformer 550 440v sec.110v with mid point earthed , earth leakage relay , brass terminal with dmc bushing , brass stud with dmc bushing for og , magnetic ol relay , thermal ol relay , on delay timer , push button and element , isolator on off rev 100a , pilot relay , switch module , isolator on off rev 200a , on off rev isolator 300a , copper terminal bushing cp og , aux. contactor 220v ac , resistance
Tender For tender for supply of mpcb and mcb - motor protection circuit breaker asper iec 947 having magnetic thermal release with 1no aux contact range 2.5 - 4 amps make siemens or schnider , motor protection circuit breaker asper iec 947 having magnetic thermal release with 1no aux contact range 0.25 - 0.4 amps make siemens or schnider , motor protection circuit breaker 10-16 amps 3pole over load range 10 -16 amps 1n0 make siemens or schnider , air break contactor ac3 duty 4kw dol minimum current rating 9a aux.contacts 2no+2nc coil voltage 220v 50/60 hz along with suitable coil suppressor make siemens or schnider , air break contactor ac3 duty 5.5kw dol minimum current rating 12amps aux contacts 2no + 2nc coil voltage 220v 50/60 hz make siemens or schnider , air break contactor ac3 duty 4kw dol minimum current rating 9 a aux contact 1no coil voltage 220v 50/60 hz along with suitable coil suppressor make siemens or schnider , miniature circuit breaker as per is 8828 1966 iec 898 c type 1amp sp breaking capacity 10 ka make siemens or schnider , miniature circuit breaker asper is8828-1996 iec 898 c type 2amps sp breaking capacity 10 ka make siemens or schnider , miniature circuit breaker as per is 8228 1996 iec 898 c type 6amps sp breaking capacity 10 ka make siemens or schnider , miniature circuit breaker as per is8828 1996 iec 898 type c 4 amps dp breaking cap 10ka make siemens or schnider , miniature circuit breaker , asper is8828 1996 iec 898 c type 6 amps dp breaking capacity 10 ka make siemens or schnider
Tender For bid to ras supply of living shelter 10 to 12 men - pre fabricated shelter made up of steel structure and hybrid pir panels in wall , fire extinguisher of capacity 2 kgs along with its accessories confirming to is 13849 two nos with each shelter , heating device kerosene based two nos heating , lightning conductor. lightning conductor will be provided as under and stores are as per appx e and drg at appx f sheet 10 10 , aggregate 20mm. stone aggregate to be crushed rock , aggregate 40mm. stone aggregate to be crushed rock , manufactured sand m sand confirming to is 383 2016 specifications for coarse and fine aggregates , bricks common burnt clay building bricks sub class b , white cement make- birla white jk cement acc packet 01 kg , water proof floor silica panels of size 600 x 600 mm with minimum thickness of 10 mm , non skid ceramic tiles coloured 7 to 8 mm thick in floors etc , prefabricated foundation reinforcement type f 2 made of 12 mm and 10 mm for steel as main bars and 8 mm dia deformed bars as in stirrups including cutting bending , form work type 2 timber form work material for columns of size 0.3 x 0.3 x 0.9m and columns footing of size 0.9 x 0.9 x 0.3 m , rapidite quick setting liquid. , ms clamp msde of ms flat 40 x 4 mm 200mm long bent in l shape with two holes of 12mm dia on each end. 04 x nut and bolt of size 10 x 50 mm with washer. , pvc ceiling rose 2 obliq 3 terminal make anchor pilot 3 plate , led tube light fitting 1 x 18w 4 feet long complete with all , xlpe insulated pvc seathed heavy duty armoured multi core cable 16 sqmm 2 core aluminum conductor for working voltage up to and including , cable pvc insulated unsheathed single core flexible copper conductor 1100v grade of size 1.5 sqmm , cable pvc insulated unsheathed single core flexible copper conductor 1100v grade of size 2.5 sqmm conforming to is 694 1990 , cable pvc insulated and pvc sheathed 1100v grade twin core with stranded aluminium conductor confirming to is 694 1990 of size 4 sq mm , flexible wire pvc insulated twin core twisted of size 22 0.0076 with copper conductor. , modular switch one way 6 amps one module confirming to is 3854 1966. , ms screw 20 mm per pkt 100 nos confirming to is 723 1972. , ms screw 35 mm per pkt 100 nos confirming to is 723 1973. , insulation tape 2 cm width 10 mtr long isi marked make steel grip. , mcb single pole 230v ac 50 hz 6 amps 10ka confirming to is 8828 1996 iec 60898 2002 suitable for lighting and other domestic loads. , mcb single pole 230v ac 50 hz 16 amps 10ka confirming to is 88281996 iec 60898 2002 suitable for lighting and other domestic loads. , mcb distribution boards in sheet metal enclosure 8 ways double door with blanks confirming to is 8623 , residual current circuit breaker with over load and short circuit protection dp 32 amps , modular switch one way 16 amp 1 module , modular socket 6a 2 obliq 3 pin combined 2 module , modular socket 6a 16a 2 obliq 3 pin combined 2 module , white cover plate with frame 3 module , white cover plate with frame 6 module , metal flush box 3 module , metal flush box 6 module , compact street light luminaire with deep drawn housing complete along with single 36w fr l , pvc casing caping pipe 25mmx16mm confirming to is 14927 part ii , pvc casing caping l bend 25mm confirming to is 371 1979 , pvc casing caping elbow 25mm dia confirming to is 9537 part iii 1983 , pvc casing caping t 25mm for conduit pipe , pvc casing caping square box 4inch x 4 inch , plastic body exhaust fan 250 mm sweep with louvers , plastic body wall mounting fan 450mm sweep , two tier sleeping bunks as per drawing attached to be provided by vendor the vertical head leg side in duble portion of size 1950x950mm shall be made of 32 mm , waste bin 120 ltr dim 480 x 550 top o.d. colour dark brown make nilkamal or equalent , plastic chair with handrest model dynasty dim 570 w x 593d x 890h. colour dark brown make nilkamal or equalent , cup board model freedom fmdr 1b dim 595 w x 354d x 1450 h colour
Tender For supply of molded case circuit breaker (mccb), 100a, 3 pole, rated voltage 415v ac, breaking ca pacity 36 ka with thermal magnetic trip unit confirming to is: 13947 part-ii (latest revision). [ warran ty period: 30 months after the date of delivery ]