Tender For notice inviting tender (nit) for hiring of farana cranerelated activity’s purpose in single bid system for“combined station works of mechanical, civil, electricaland instrumentation works and other facilities underkandla-gorakhpur liquefied petroleum gas (lpg) pipelineproject at group 2: bina in madhya pradesh state”
Tender For e-tender are invited from the reputed general mechanical,electrical, instrument & other items purchase third e-tender(non authorized) for 2500 tcd sugar factory within a timeschedule
Tender For supply of lcr meter, (inductance, resistance, frequency, capacitance meter.) range: resistance 20 ohm to 20 m ohm, inductance 20 microh to 200 h, capacitance: 20 pf to 2000 microf, test frequency - 100hz to 1khz. make: fluke lcr 55 a or ambrobe lcr 55 a or precision 870 b or gw instek-lcr 916 model .
Tender For supply of electrical and electronics devices - supply of electrical and electronics devices (refer nit document) - electrical and electronics devices (refer nit document), fixed and variable power supply dc regulated dual output power supply, 0 30 v / 0 5 a, continuously variable with coarse and fine adjustment knobs, digital display for voltage and current, short circuit & overload protection., lcr meter measures inductance (l), capacitance (c), and resistance (r); test frequency 100 hz 100 khz; 4 digit lcd display; auto/manual range; accuracy 0.2%; rs232/usb interface optional., variable isolation transformer input: 230 v ac 10%, output: 0 270 v ac variable, 1 kva capacity, single phase, continuously variable output with toroidal winding and analog voltmeter display, with isolation protection., function generator frequency range: 0.1 hz 1 mhz, sine/triangle/square waveforms, amplitude up to 20 v p-p, dc offset control, output impedance 50 , digital frequency display., oscilloscope dual-channel digital storage oscilloscope (dso), bandwidth 100 mhz, sampling rate 1 gsa/s, 7 color tft display, usb interface for data storage, auto-set function., clamp multimeter ac/dc voltage: 600 v, current range: up to 1000 a ac/dc, resistance measurement: 40 m , continuity and diode test, true rms, lcd backlight, cat iii 1000 v safety rated., digital multimeter handheld digital multimeter, 3 /4 digit lcd display, ac/dc voltage up to 1000 v, current up to 10 a, resistance up to 40 m , diode and transistor test, auto power-off., digital storage oscilloscope with mso bandwidth 100/200mhz no. of channels 2+ext/4, sampling rate 1gsa/s, record length 14mpts, max memory depth 14mpts, soldering iron station power 580w airflow50l/min(max), temp 100 c to 450c, led magnifying lamp table clamp type lense dia. 125mm,magnification 2 to 8 diopter, light 9w led, bread board assembly tie point620, 5-tie point terminals 96 size4.96"x2.25", wire gauge 22awg
Tender For corrigendum : procurement of testing equipment for all power houses at thc sirmour - digital insulation testers (megger)range: 0-100/250/500/1000v, digital insulation testers (megger)range: 0-100/250/500/5000v, digital multimeterfeatures:dc & ac voltage; ac & dc current; continuity & resistance ; capacitance and inductance; checking of diodes/ transistors, single phase variable voltage autotransformers: details of single phase auto transformer 15a rating -input: 220v ac 10%; output: 0 to 270 volts.rating: 15 amps, three phase variable voltage autotransformers: details of three phase auto transformer 15a rating -input: 415v ac 10%; output: 0 to 500 volts, 3 phases.rating: 15 amps., tong tester cum multi meter (digital) (clamp on meter for ac measurements) specification for 0-1000a ac digital tong tester (clamp on meter) - current range: 0 to 1000 a (with settings of 1/10/20/40/100 a/500a/1000a auto ranging); voltage range: 0 to 60/300/600 v ac; accuracy: 0.3% or better, tong tester cum multi meter (digital) (clamp on meter for dc measurements) specification for 0-300a dc digital tong tester (clamp on meter) - current range: 0 to 300a (with settings of 1/10/20/50/100 a/300a auto ranging) ; voltage range: 0 to 60/120/300 v dc.accuracy: 0.3% or better., tong tester cum multi meter (digital) (clamp on meter for ac/dc measurements) specification for 0-100a ac digital tong tester (clamp on meter) - current range: 0 to 100 a (with settings of 00-20ma/100ma/500ma/1a/10a/50a/100a auto ranging); voltage range: 0 to 60/300/600 v ac; accuracy: 0.3% or better, digital phase sequence indicator: dial size: 96x96mm (minimum) ; working voltage: 50 to 500v ac; frequency: 25 to 60 cycles., digital earth resistance clamp meter with leakage current measurement
Tender For construction of rcc framed structure for radio radar mro room and electricalinstrument mro room and garrett engine dressing or servicing cell with controlled environment room near steel hangar at hal tad kanpur
Tender For providing, laying, jointing, testing and commissioning of sewerage system and all ancillary works along with design, construction, supply, installation, testing and commissioning (civil, mechanical, electrical, instrumentation & other necessary works) of sewage treatment plant based on sbr process including 1 year defect liability with provision of reuse of treated waste water with 10 years o&m for town under package amrut 2.0/raj/sew/42