Tender For supply of electrical item - 3010304, 10.000, electricalinstruments item contact cleaner.net content 500mlmake;loozen co-contact cleaner., 3197132, 4.000, make haweelscentur neo led flood light.500lm6kv surge protectionik07 impact resistnt6500k cool day lightsrequire for dg section/refrigeration section where cealing height is very high and where tube lights not suitable so want to install this, 3871460, 10.000, cealing fan capacitor.3.15 micro farad single phase.make epcos/philips/or standard make, 3136413, 10.000
Tender For supply of electrical spare item for khunti d d - thyristor module psthm 162 19 mcc 200 16 io1 , thyristor module psthm 200 16 mcc 312 18 io1 , tube light 20 w led , flameproof light 60 w led , braided copper wire 6 sq.mm , crocodile clip , flameproof safety torch , ceiling bldc motor fan , rccb 2 pole 30 ma 64 a , earthing cable 10 sq mm copper , copper strip 25 sq mm , sfu unit 63 a 3 pole with neutral , 1 core 1.5 sq mm pvc copper circular sheathed cable with rigid conductor , 1 core 1 sq mm pvc copper circular sheathed cable with rigid conductor , motor operator geared motor device of acb , undervoltage release uvr of acb , shunt trip coil , shunt closing coil , acb front cover sace emax e1n ms 10 , acb front cover sace emax e3n ms 25 , hrc fuse din 400a , hrc fuse base , soft-starter front keypad lcd display assembly with control card , hrc fuse din 250a , hrc fuse din 200a , hrc fuse din 63 a , hrc fuse din 80a , mcb 40a 2pole 240v
Tender For repair and annual maintenance of mini water supply installations in arsikere cmc limits - supplying and laying (dwc) hdpe pipe 32mm dia, replacement of tpn 40a mcb, supplying & fixing ammeter 0to 30ammeter, repair and re-condition of pump set of above 10 h.p to 15 h.p/12 to 20 stage capacity which includes replacement of all items, fixing, transportation and labour charges, for details, refer technical specifications and schedule of requirements in the tender document., repair and re-condition of pump set of above 5 h.p to 10 h.p/8 to 14 stage capacity which includes replacement of all items, fixing, transportation and labour charges, for details, refer technical specifications and schedule of requirements in the tender document., supplying and fixing porcelain fuse with cut out 125 amps, replacement of tata class b heavy duty 2inch gi collar, replacement of 6h.p 10 stage pump set, re-winding and re-condition of submersible motor of above 10 h.p to 15 h.p capacity which includes replacement of all items, fixing, transportation and labour charges, for details, refer technical specifications and schedule of requirements in the tender document., re-winding and re-condition of submersible motor of above 5 h.p to 10 h.p capacity which includes replacement of all items, fixing, transportation and labour charges, for details, refer technical specifications and schedule of requirements in the tender document., labour charges for lifting and dropping pump sets, digging of trench including labour charge, supplying and replacement of lt ug cable 4 core 10 sq mm, supplying and replacement of submersible flat pvc copper cable 3c x 6 sq mm, starter repair which includes replacement of spare parts such as contactors, push buttons, overload relay, no volt coil etc.., with complete wiring, replacement of starter box, supplying & replacement of push button switches of the starter, supplying and replacement of pcb board in the single phase preventer, supplying and replacement of no-volt coil of the contactor, supplying and replacement of contactor suitable to operate upto 20 h.p capacity motor, supplying & fixing single phase preventer suitable for motor upto 20 h.p capacities, supplying & fixing voltmeter 0 to 600 volts, supplying and fixing porcelain fuse with cut out 63 amps, supplying and fixing porcelain fuse with cut out 32 amps, supplying and fixing porcelain fuse with cut out 16 amps, supplying of 8inch bore cap for mws, flushing of existing borewells, re drilling of existing bore wells, replacement of tata b chass heavy duty 2inch gi pipe, replacement of indicators, replacement of starter suitable for pump set upto 15 h.p capacities, replacement of starter suitable for pump set upto 10 hp capacities, replacement of 12.5 h.p 20 stage pump set, replacement of 10 h.p 14 stage pump set, replacement of 10 h.p 12 stage pump set, replacement of 7.5 h.p 12 stage pump set, replacement of 7.5 h.p 10 stage pump set, replacement of 6 h.p 8 stage pump set, replacement of rotary selector switch, labour charges for lifting of failed pump set , labour charges for lifting of struck pump set, threading of g.i pipes, replacement of shunt capacitor upto 10 kvar capacity, replacement of wooden panel board, replacement of over head service mains upto 10 sq mm capacity aluminium wires
Tender For corrigendum : supply of different materials used for testing at electricity test division, unnao under electricity distribution circle, unnao. - o/c & earth fault relay (ashida adr 241 b), clamp meter (0-20a), combination pilier (taparia), rachet set (taparia), grinder bosch (240 volt, ac operated), drill machine (240 volt, ac operated), spanner set (taparia), pcv tape (red, yellow & blue) colour, pin type & u type copper lug 2.5 mm2 (100 each), dc indication led (24 volt to 36 volt) suitable for 11kv & 33kv control pannel, flexible copper wire havells (red, yellow & blue, black color) 2.5mm2, tripping coil with assembely make tripping coil assembly stable 33 kv vcb (stelmec, toshiba, cg, schneider), oti(oil temperature indicator) with limit switch alarm & trip contact, temp range (0 c to 150 c), wti (winding temperature indicator) with limit switch alarm & trip contact, temp range (0 c to 150 c) with gradient adjustment through a shunt for ct secondary input (1amp to 5amp), closing coil with assembely make tripping coil assembly stable 33 kv vcb (stelmec, toshiba, cg, schneider)
Tender For re tender for the supply of electrical materials to all the factories of tantea - supply of electrical materials to the factories of tantea., 250 kva kirloskar cummins genset b check kit, 250 kva kirloskar cummins genset governer cable, 320 kva greaves genset b check kit, f 6 381.03.000 expansion bellow, f 6 618.01.000 expansion bellow 4", f 6 381.04.000 joint between bellow and gas out, f 6 026.03.000 joint of exhaust manifold, 50.080.10.000 s.steel out m 10- a isi - 30, 50.006.08.000 nut m 8x1.25 gr 8.8, 06.436.01.000 spin on filter for lub oil, 48.117.04.000 fuel filter element prefilter, 48.117.05.0.00 fuel filter micro, lub oil filter (for 250 kva genset - kirlosker make) with rubber washer, diesel filter (for 250 kva genset - kirlosker make) with rubber washer, diesel pre- filter (for 250 kva genset - kirlosker make) with rubber washer, lub oil filter (for 320 kva genset - kirlosker make) with rubber washer, diesel filter (for 320 kva genset - kirlosker make) with rubber washer, diesel pre- filter (for 320 kva genset - kirlosker make) with rubber washer, lub oil filter (for 250 kva genset - greeves make) with rubber washer, diesel filter (for 250 kva genset - greeves make) with rubber washer, diesel pre- filter (for 250 kva genset - greeves make) with rubber washer, lub oil filter (for 320 kva genset - greeves make) with rubber washer, diesel filter (for 320 kva genset - greeves make) with rubber washer, diesel pre- filter (for 320 kva genset - greeves make) with rubber washer, lub oil filter (for 320 kva genset - powerica make) with rubber washer, diesel filter (for 320 kva genset - powerica make) with rubber washer, diesel pre- filter (for 320 kva genset -powerica make) with rubber washer, air filter (250 kva genset kirlosker make), air filter (320 kva genset kirlosker make), air filter (250 kva genset greeves make), air filter (320 kva genset greeves make), f6 729.07.0.00 main element for 250 kva aircleaner, f 6 729.08.0.00 adwrt wkwnwbr die 150 kva aircleaner, 50. 508.05.0.00 copper washer 8x12, 50. 508.11.0.00 copper washer 14x18, 50. 006.10.000 nut m 10 x 1.5 gr 8.8, 50. 508.10.0.00 copper washer 12x18, 50. 505.08.0.00 spring washer m8, f 6 537.02.0.00 starter ring t/c no. 68 f 636 2360, 250 kva avr alternator stampford, 320 kva avr kirloskar alternator, 320 kva water cooling pipe connecting, rubber hoses complete set, 11 kv ht transformer structure spares, 11 kv ab switch droped out fuse moving and stable contact with hylam bar set, copper riben 1/4" x 1" x 1 mtr, lightning arrester 11 kv, lightning arrester 22 kv, lightning arrester 30 kv, silica gel, transformer oil, 11 kv hand gloves-pair, transformer breather, 11 kv pin type insulator, 11 kv ab switch siemens make, 11 kv ab switch spares - male & female contact, lever etc., siemens make, 800 amps acb-l&t make u/v coil - 230 v, 800 amps acb-l&t make shunt coil - 230 v, circuit breaks, mccb - l & t make - 630 a ( dth 630), mcb - 1 p - 6 a, mcb - 1 p - 10 a, mcb - 2 p - 16 a, mcb - 2 p - 32 a, mcb - 3 p - 16 a, mcb - 3 p - 25 a, mcb - 3 p - 32 a, mcb - 3 p - 40 a, mcb - 3 p - 50 a, mcb - 1 p - 20 a, mcb - 4 p - 63 a, mcb 2 pole - 16 amps, mcb single pole-6 amps, mcb single pole-15 amps, mcb single way metal box (adapter), mcb 2 way metal box (with adapter), mcb 2 way metal box (without adapter), mcb 4 way metal box (without adapter), mcb - distribution boards - 12 way hawks/ l & t, mcb - distribution boards - 8 way l & t, mcb - distribution boards - 6 way, m - 16 acb, top fixed contactor (g.e power control make) m-pact - 610 l & t, m - 16 acb, bottom fixed contactor (g.e power control make) m-pact - 610, m - 16 cluster contactor, spare kit fo r 600 a o.c.b easun -fb 3, apfc for 50 kvar, 25 kvar power capacitor siemens, 15 kvar power capacitor siemens, 10 kvar power capacitor siemens, male and female contactor for 800a acb, mpcb, mpcb - control and switch gear contactors make tcms - 63, mpcb - control and switch gear contactors make tcm
Tender For annual work contract for onsite calibration of electricalinstruments/equipment of testing division, ahp, chp, emd-i, emd-ii & c&i at abvtps, cspgcl, janjgir-champa.