Tender For corrigendum : transgrid down stream works at 110kv substation terls renewal of control cable connections for ct pt circuit breaker bus isolators and lightning arresters of 20 mva transformer unit 2 necessitated by transformer repositioning
Tender For supply of integrated queue management terminal unit , system installation and commissioning service , display and notification interface system , connectivity and network integration module , software configuration and control interface
Tender For corrigendum : supply of supply of floor mounted direct radiography system with dual detector under buy-bcak policy floor mounted direct radiography system with dual detector floor mounted direct radiography system with dual detector:- 1.generator the generator should be high frequency capacity of 30 kw or more. kv range should be 40 kv- 125 kv or more. the output at 80 kv should be 400 ma or more. generator frequency should be 200khz or more 2. x-ray tube and collimator the x-ray tube should be of rotating anode with dual focus having the following sizes: (i) large focus: 1.5 mm or less. (ii) small focus: 0.6 mm or less the unit should have anode heat storage capacity of 100 khu or more. distance measuring scale should be provided. should have an multi-leaf collimator having bright light source auto shut provision for the light along with automatic image cropping facility. the light output should be minimum 160lux tube rotation on vertical axis should be - 180 degree locked (clockwise) & + 120 degree (anticlockwise) at least with end stopper. the tube column should be ceiling-free floor mounted and should have longitudinal travel of a minimum 1500mm. touch screen display on tube head to control kvp & mas as well as selection of body parts. 3. vertical detector stand the unit should be provided with vertical stand. the unit should have provision to do all upright x-rays. the vertical detector should travel from at least 1.4 ft to 5.5 ft above floor level. it should be flat vertical motion can be locked in any position. 4. table the table top should be floating with transverse and longitudinal movements 250 mm, 300 mm respectively or better. the table should have a weight bearing capacity of minimum 200 kg or more. the table should have anti scatter grid electromagnetic ) /bid number : gem/2026/b/7398823 * /dated: 28-03-2026 & & / bid document 1 / 8
Tender For corrigendum : procurement of various ht & lt power cable and control cable regarding to bcn-15 a&b cable gallery restoration work at 2x250 mw unit 1&2 bltps.
Tender For corrigendum : design, engineering, supply, erection, testing and commissioning of latest distributed digital control monitoring and information systems (ddcmis) for open loop control systems (olcs), closed loop control systems (clcs), furnace safeguard supervisory - design, engineering, supply, erection, testing and commissioning of latest distributed digital control monitoring and information systems (ddcmis) for open loop control systems (olcs), closed loop control systems (clcs), furnace safeguard supervisory system (fsss), soot blower system, turbine protection system and power plant controls by dismantling existing outdated 9020 control systems in unit – iii of ttps
Tender For bid to ras supply of handmic watertight or p 66 or 10 handmic with plug wt ip 66 , main control unit , handheld microphone , tone generator pcb , horn loudspeaker , pa amplifier make ms cooper cut esse , glass cartrige fuse 10a , horn type speaker , horn speaker 15w water tight ip 66 , mic , hand held mic , non water tight mic , microphone make halmco model p 66 , water tight mic , driver 100w for dh 30 or 50 wt ip 67 , cw 4tvs or f loud speaker w fuse 3 wire overdrive max 3w w or metal plate and 2 , pa panel with 5 zones and all call 3 alarm buttons w or cover w or t , hand mic 10m cable with plug wt ip 66 , main broadcast hand mic , horn speaker
Tender For corrigendum : repairing of 3.3kv capacitor bank automatic control unit installed at 33kv main substation, rani atari ug mines, rani atari sa
Tender For corrigendum : tender for supply of supply of digital tele-protection couplers with all acessories as per ts , supply of e1 to optical converters as per ts , supply of 6 core armoured optical fibre cable , supply of line interface unit for upto 6 terminations ( switchyard side) , supply of line interface unit for upto 24 terminations ( control room side) , installation , comissioning and testing of dtpc , installation , comissioning and testing of e1-fo converter , installation , comissioning and testing of liu-6 port , installation , comissioning and testing of liu-24 port , installation , comissioning and testing of ofc , spare - supply of digital tele-protection couplers with all acessories as per ts , spare - supply of e1 to optical converters as per ts , spare - supply of 6 core armoured optical fibre cable , spare- supply of line interface unit for upto 6 terminations ( switchyard side) , spare- supply of line interface unit for upto 24 terminations ( control room side) , supply of digital tele-protection couplers with all acessories as per ts , supply of e1 to optical converters as per ts , supply of 6 core armoured optical fibre cable , supply of line interface unit for upto 6 terminations ( switchyard side) , supply of line interface unit for upto 24 terminations ( control room side) , installation , comissioning and testing of dtpc , installation , comissioning and testing of e1-fo converter , installation , comissioning and testing of liu-6 port , installation , comissioning and testing of liu-24 port , installation , comissioning and testing of ofc , supply of digital tele-protection couplers with all acessories as per ts , installation , comissioning and testing of dtpc , spare - supply of digital tele-protection couplers with all acessories as per ts , supply of digital tele-protection couplers with all acessories as per ts , supply of e1 to optical converters as per ts , supply of 6 core armoured optical fibre cable , supply of line interface unit for upto 6 terminations ( switchyard side) , supply of line interface unit for upto 24 terminations ( control room side) , installation , comissioning and testing of dtpc , installation , comissioning and testing of e1-fo converter , installation , comissioning and testing of liu-6 port , installation , comissioning and testing of liu-24 port , installation , comissioning and testing of ofc , spare - supply of digital tele-protection couplers with all acessories as per ts , spare - supply of e1 to optical converters as per ts , spare - supply of 6 core armoured optical fibre cable