Tender For supply of insulated bar - end cover as per bhel drg no 26992190049 rev 05 varno00 , end cover as per bhel drg no 26992190049 rev no 05 varno 001 , molded panel rear side as per bhel drg no 36992190024 rev no 03 item no 001 var no 00 , topslashbottem front panel as per bhel drgno 36992190021 rev no 03 item no 001 var no 00 , topslashbottem front panel as per bhel drgno 36992190021 revno 03 item no 002 var no 00 , end covertopslashbottem dc bus bar side as per bhel drgno 36992190020 rev no 03 item no 001 var no 00 , end cover topslashbottem cooling as per bheldrgno 36992190020 revno 03 item no 002 var no 00 , end cover topslashbottem drgno as per bhel 36992190020 rev no 03 item no 003 var no 00 , middle front panel with cutout as per bheldrgno 26992190147 rev no 02 var no 00 , middle front panel with out cutout as per bhel drg no 26992190147 rev no 02 var no 01 , gland plant heat exchanger as per bhel drgno 46500300036 rev no 02 var no 00 , blanking plate as per bhel drgno 46500300034 rev no 01 var no 00 , duct support rectifier as per bhel drgno 46992190014 rev no 02 var no 00 , trunking details rh and lh drgno 46500900046 rev no 01 var no 00 , trunking details top and bottem as per bhel drg no 46500900047 revno 02 var no 00 , gland plate as per bhel drgno 46500700001 revno 02 var no 00 , fibre glass header tank as per 36500600024 rev03 , insulation sleeveto as per bhel drgno 46992190011 rev02 , insulating stud to as per bhel drg no46500300027 rev 03 , stack support to drgno 46500300037 rev03 item 1 , stack support drg no 46500300037 rev03 item2 , stack support to drg no46500300037 rev03 item03 , toughened glass to drg 46500300032 rev02 , phase barrier to drg 36500300104 it01 rev no 01 , nylon braided pvc hose sl25 id25mm od35mm , nylon braided pvc hose sl010 id10mm od16mm , ss304 klipco tightening clip 28mm od
Tender For procurement of jigs and fixtures as per drawing from hal registered vendors - end cover as per bhel drg no 26992190049 rev 05 varno00 , end cover as per bhel drg no 26992190049 rev no 05 varno 001 , molded panel rear side as per bhel drg no 36992190024 rev no 03 item no 001 var no 00 , topslashbottem front panel as per bhel drgno 36992190021 rev no 03 item no 001 var no 00 , topslashbottem front panel as per bhel drgno 36992190021 revno 03 item no 002 var no 00 , end covertopslashbottem dc bus bar side as per bhel drgno 36992190020 rev no 03 item no 001 var no 00 , end cover topslashbottem cooling as per bheldrgno 36992190020 revno 03 item no 002 var no 00 , end cover topslashbottem drgno as per bhel 36992190020 rev no 03 item no 003 var no 00 , middle front panel with cutout as per bheldrgno 26992190147 rev no 02 var no 00 , middle front panel with out cutout as per bhel drg no 26992190147 rev no 02 var no 01 , gland plant heat exchanger as per bhel drgno 46500300036 rev no 02 var no 00 , blanking plate as per bhel drgno 46500300034 rev no 01 var no 00 , duct support rectifier as per bhel drgno 46992190014 rev no 02 var no 00 , trunking details rh and lh drgno 46500900046 rev no 01 var no 00 , trunking details top and bottem as per bhel drg no 46500900047 revno 02 var no 00 , gland plate as per bhel drgno 46500700001 revno 02 var no 00 , fibre glass header tank as per 36500600024 rev03 , insulation sleeveto as per bhel drgno 46992190011 rev02 , insulating stud to as per bhel drg no46500300027 rev 03 , stack support to drgno 46500300037 rev03 item 1 , stack support drg no 46500300037 rev03 item2 , stack support to drg no46500300037 rev03 item03 , toughened glass to drg 46500300032 rev02 , phase barrier to drg 36500300104 it01 rev no 01 , nylon braided pvc hose sl25 id25mm od35mm , nylon braided pvc hose sl010 id10mm od16mm , ss304 klipco tightening clip 28mm od
Tender For supply of lt distribution panel with 415 v, 3 phase, 50 hz copper bus bar, indication lamp, metering arrangement (vm & am), floor mounted, steel sheet enclosure thickness 14 swg comprising of 3 nos. 800 a 4 pole edo type acb microprocessor based (02 nos. as incomer(scada compatible) & 01 no. as bus coupler and 02 nos. 400a 4 pole mccb, 4 nos. 250a 4 pole mccb , 03 nos. 100a 4 pole mccb as outgoing, as per the attached detailed description no. ser/elec/gs/description/lt panel/1/rev-2/june 2025 & tentative dimension of (3600 mm x 800 mm x 1800 mm). however, the layout drawing shall be submitted bythe supplier along with the general arrangement drawing (gad) for railway's approval before commencement of supply. [ warranty period: 30 months after the date of delivery ]
Tender For s/l of cable for 06 nos. high mast light, pump house, dda office, s/f of main switch, bus bar panel and dismentling and refixing of 01 no. high mast light pole etc. work at n.m.y. naubasta, kanpur.
Tender For repair/ replacement of earthing , lt panel , mccbs, bus bar, changeover, painting of pole and other e/m miscellaneous work at bb cantt, srinagar
Tender For corrigendum : repair and maintenance of lt switch gear, distribution panel, bus bar, lt power cable and allied electrical work at technical area under ge (af) ambala
Tender For repair/replacement of lt electric supply network ,lt electric ug cables, lt panel, bus bar chamber, other connected works at lower garrison and lt electric over head lines at mil stnyol
Tender For supply, erection, testing and commissioning of 136 m3/ hr. 30000 gph (uk) capacity hscf pump set, total head 50 mtr, with suitable motor 4p/tefc/ie3 horizontal foot mounted type with rating 415v, 50hz, 3 phase along with soft starter panel (with copper bus bar), pump set specifications shall conform to pcee/grc's latest specification and as per annexure a (inclusive of dismantling, making concrete foundation work, supply of suitable size foundation bolts and all requisite materials). spares & accessories of pumpset to be supplied with each set as per clause no. 3 & 4 of pcee/grc%u2019s specification no. cee/s/185/hscf pump/9/98/revised july 2022. location: sonanala pump house under ssee/g/sini. [ warranty period: 30 months after the date of delivery ]
Tender For survey, investigation, design, supply, erection, testing and commissioning of required number of vertical turbine pumps coupled to ht motor for providing irrigation facility to suffering atchkat 2847 ha. of lateral no.27 to 32 of dy.no.6 of shahapur branch canal from karnal nala under karnal lis in shorapur taluk yadagir district viz., construction of diversion weir, intake forebay, jackwell cum pump house, manifold along with electricalpanel, soft starter, capacitor, 11 kv power transformers, ht bus bar / cabling, 11/6.6 kv sub-station, power line and 11 kv terminal bay, ms rising main, valves and construction of delivery chamber, erm to lateral 27 & 31 of d-6 (selected reach) supply of spare, accessories and tools including operation & maintenance of the entire system for five years from the date of successful commissioning of karnal lift irrigation scheme on turnkey basis.