Tender For supply of ht vcb mechanism part no.ht050001 , trip and close coil part no.ht060001 , ht current transformer part no.ht010001 , ht potential transformer part no.ht020001 , ht indoor off load isolator part no.ht030001 , spout for vcb part no.ht01501s , auxiliary contactor part no.ht021001 , power pack by rectifier part no.ht024001 , plug and socket part no.ht022001 , auxiliary contact block part no.ht021001a , auxiliary transformer part no.ht023001 , ht pt fuse part no.ht027001b , ht vcb vacuum interrupter part no.ht040001
Tender For dismantling of existing porcelain lightening arrestors, surge counters, cvts, acsr conductor, supporting porcelain insulators, supporting structures, complete form line side insulator to takeoff tower for 66kv shimoga bhadra lines 1, 66kv shimoga bhadra lines 2 and lh transmission lines.2)2)supply, erection, testing and commissioning of 3 nos. of 66kv transmission line equipments like cvts, polymeric lightening arrestors with surge counters, supporting polymeric insulator stacks, lynx acsr conductor, clamps, connectors, structure etc. complete from line side isolator to take off tower of 66kv transmission line equipments from line side isolator to take off tower at bhadra generating station.3.dismantling of existing 72.5kv, 0.5cl current transformers, supply, erection, testing and commissioning of 0.2 class, 72.5kv current transformers for 12mw river bed units 1 and 2 at bgs.4.supply of essential spare 04 nos. of 66kv polymeric insulator stack and 01 no. of 0.2cl 72.5kv current transformer.5.jungle clearance along the lines wherever necessary.6.the scope also includes testing at works before dispatch, pre-commissioning and commissioning tests at site and the performance guarantee tests in respect of 72.5kv cts, 60kv las, 72.5kv cvts required for bhadra generating station.7.the scope of supply shall include all accessories, marshalling box, terminal connectors, wedges, clamps, supporting structure etc., which are necessary for assembly and erection of ct, cvt & la.8.modifications required for foundation and support structures to erect newly supplied cts, cvts and las shall be carried out by contractor at no extra cost.
Tender For bid to ras corrigendum : supply of pharmacy - high speed centrifuge , isolator transformer , digital plethysmometer , trolley for mice and rat cage , visitor chair , library staff station reader , uninterrupted power supply , centrifuge , electronic balance , incubator with shaker , deep freezer , visicooler
Tender For annual preventive / breakdown maintenance of equipments at 220/132/33kv substations under 220kv oandm division rishikesh - 220 kv switchyardtightening of 220 kv bay equipments (cb, line isolator, transfer isolator, ct, cvt and la including all connectors of droppers/runner/jumpers), cleaning of 160 mva transformer by cleaning of whole body, accessories alongwith tightening of bushing connectors, earthing, proper cleaning of cooling system, replacement of silica gel etc.complete, cleaning of 220 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles and assistance in testing work, overhauling of mechanism of 220 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete, replacement of conductor jumpers/runner/dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 220 kv terminal connector/clamp/jaw/blade etc. and tightening of related equipment (including replacement of minor conductor segment/patch), replacement of 220 kv take-off assembly/ moving head assembly/rotary head devive etc. (including proper alignment) complete, unforseen work/maintenance of equipments/panels etc including tracing of fault &remidial action as per direction of site engineer, topping up of sf-6 gas in 220 kv circuit breaker/ oil in ct & cvt under breakdown/preventive maintenance (including shifting of gas cylinder/oil drums), repairing of hpsv lamp fittings/replacement of led fittings at 220 kv switchyard., 132 kv switchyardtightening of 132 kv bay equipments (cb, line isolator, transfer isolator, ct, cvt and la including all connectors of droppers/runner/jumpers), cleaning of 132 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles and assistance in testing work., overhauling of mechanism 132 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/ polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete., replacement of conductor jumpers/runner/dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 132 kv terminal connector/clamp/jaw/blade etc. and tightening of related equipment (including replacement of minor conductor segment/patch), replacement of 132 kv take-off assembly/ moving head assembly/rotary head devive etc (including proper alignment) complete, unforseen work/maintenance of equipments/panels etc including tracing of fault &remidial action as per direction of site engineer., topping up of sf-6 gas in 132 kv circuit breaker/ oil in ct & cvt under breakdown/preventive maintenance (including shifting of gas cylinder/oil drums), repairing of hpsv lamp fittings/replacement of led fittings at 132 kv switchyard., 33kv switchyard:tightening of 33 kv bay equipments (cb, line isolator, ct including all connectors of droppers/runner/jumpers), cleaning of 40 mva transformer by cleaning of whole body, accessories alongwith tightening of bushing connectors, earthing, proper cleaning of cooling system, replacement of silica gel etc.complete, cleaning of 33 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles, assistance in testing work., overhauling of mechanism 33 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/ polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete, replacement of conductor jumpers/ runner/ dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 33 kv terminal connector/clamp/jaw/blade etc. and tighgtening of related equipment (including replacement of minor con
Tender For supply of mine line make spares for different equipments - cover bolts , isolator assembly k3 on off , isolatorassembly k4 on off 300a , mounting bar for isolator , coilspring for isolator up to 400a , isolator micro switch assly ,catcher assembly , arc chutes , ammeter100 5 for acb ,ammeter 200 5 for acb , ammeter 300 5 for acb ,ammeter 400 5 for acb , push button actuator for el test ,push button actuator for el reset , potential transformer ,incoming gland , outgoing gland , glass fuse with holder ,power cable for 300a for breaker chamber ic og set ,power cable for 400a for breaker chamber ic og set ,power cable for 200a for breaker chamber ic og set , limitswitch 2no 2nc for breaker , brass terminal , push buttonwith spindle , brass terminal for cp , earth leakage relay50 750m a with time lag with cbct , moving contract forisolator , overload assembly breaker 30a 100a , overloadassembly breaker 110a 200a , overload coil 200 a , movingcontact for breaker upto 200 amps , moving contact forbreaker 400 amps , shunt trip assly complete. , no volt coilassy. under voltage coil assy. without moulding , no voltcoil assy. under voltage coil assy. with moulding , currenttransformer for ammeter , busbar , indicating lamps ,moving contact finger 400a , fixed contact assy. forbreaker , operating handle for isolator , terminal bushingwith insulator dmc incoming 6mm 20mm , terminal bushingwith insulator dmc incoming 8mm 20mm , fixed contactassy. for isolator 400a , overload assembly breaker 310a400a , arc chutes pillar , fixed contact breaker , potentialtransformer 80v , overload assembly breaker 210a-300a ,limit switch no nc for breaker , on off isolator 300a ,rectifier , ht bushing with stud. 3.3kv , reveering isolator3.3kv , ht rec pt fuse , p fuse plate wiring ass. , ht fusesupport base eppxy cast , aux. transformor single phase , support base eppxy cast , aux. transformor single phase , voltmeter selector switch , potential transformor ,isolator handle , off delay timer , incoming throughgoing sealing box with cone and gland assy , outgoingterminal swaling box with cine gland 3 way , copperterminals with dmc bushing , brass terminal with dmcbushing , brass terminal with nylon bushing , isolatorhandle , on off isolator 100a , glass fuse with holder , noactuator , nc actuator , relay coil voltage 2co contact ,pot. transformer , push button with spindle , actuator nonc , hrc fuse 16a , hrc fuse 63a , sensitive earthleakage relay 50 300ma with variable time lag , indicatingled , body bolt , ammmeter , core blancetransformer , thermal overloderelay with block , isolatork3 on off , thermal ol relay ctr 50 5 range 20a 50a ,ammeter 120 5 for lt starter , on delay timer , potentialtransforiner , aux, contactor220v ac , glass fuse withholder , potential transformer 80 va , sensitive earthleakage relay 50 300ma with variable time lag with controltransformer and suitable cbct , pilot relay , brassterminal with dmc bushing , brass stud with dmcbushing for og , hrc power fuse , isolator handle ,thermal o l relay ctr 120 5 range 48a 120a , off delaytimer , aux. relay 220v ac coll 3co base , multi pilot relay12.5 dc , single phasing preventer current operated ,single pole two way toggle switch , actuator no , actuatornc , push button element , isolator on oft rov 300aa ,isolator 3p on off 100a , indicating lamp , potentialtransformer , ht bushing , control relay 110v , dcpower pack , hcr ht pt fuse 3.3kv , pct transformer, aux contractor , natutral earthing resistor , vcbclosing coil , vcb shunt trip coil , vacuuminterrupter , neutral monitoring relay withresistance , earth leakage 5 750 ma and 750 ma 2 a dualsetting with time lag with cbct , 3 pole oil dashpot relay300 5 , dc power pack , vcb limit sweitch , hv bushuing ,isolator , current transformer , vcb shunt trip coil , controlrelay , capictor trip device , vaccum circuit breaker , pottransformer 500va , indicating lamp , contrtol fuse , undervoltage r...
Tender For supply of isolator, on off reverse, 400a,typ 3pair, part no. 201080012 , vacuum conactor, 6600v,savac4, part no. 201200006 , closing coil rating 220v, type dc, part no. 701040040 , contact block for vcc, 2no and 2nc, dc, part no. 201010048 , current transformer, 60by5a, lat30, part no. 201040278 , ammeter ratio 30by5a, type so65v, part no. 201100033 , elr 220v, with cbt 80sqmm, 100-750ma, elm-8, part no. 601010035 , single phase pt 6600v-300va, 110v-0-110v, part no. 201040211 , bushing for incoming and througoing, htta16dia, part no. 601030009