Tender For corrigendum : tender for supply of set of o rings , o ring for pump , auto air vent valve , guide cylinder , o ring for pump , bearing for motor , push button , resilient stator , retaining ring for pump , coupling pad for pump , pilot solenoid valve , pressure gauge (-1 to 5 bar) , helical rotor for pump , level control pcb , indicating lamp led , tie rod , o rings , gland packing for pump , rear bearing for pump , coalescer filter , electro pneumatic valve , pneumatic cylinder , coalescer disc stack , guide cylinder , on off switch , pcb for probe , stator resilient stator for pump , rotor helical rotor pump , tie rod for pump , aux transformer , interconnecting cable between probe and panel , on/off switch , connectors , level sensing probe , electromagnetic relay , pneumatic cylinder , front rear bearing for motor , indicating led green , pcb c , pcb d , glass tubes , buzzers indicating led , v belt , coalescer element , gaskets , buzzer , gasket for optical glass , fuse , piolet solenoid valve set of o rings of pneumatic valve , gland packing for pump , pcb c , gaskets for optical glass , tube glass optical for optical cell , pcb f mother board , i r detector for optical cell , pcb e , pcb b , front bearing for pump
Tender For corrigendum : providing of calibration services - annual maintenance contract of trimble electronics totalstation; as per scope of work; drdo facilities; buyer premises (onsite)
Tender For corrigendum : supply of 5000 v insulation tester , decade resistance box , hv testing kit 250 kva ac , 3 phase portable transformer turns ratio and vector group meter , port. digital dc resistance meter , portable high current digital micro ohm meter , port. prim. and sec. curr. injection test , portable automatic earth tester , univ microproc based relay testing kit , multi mtr digital portable , digital frequency meter , digital sound level meter , digital tachometer non contact type , digital tachometer contact type , cable fault location set , testing kit for calibrating the digital energy meter , sf6 gas leak detector , hydrogen gas leak detector , vacuum measurement meter , portable light intensity lux meter , portable circuit breaker motion analyser , thermal imaging camera , portable high voltage live line detector , tong tester , portable phase seq continuity indicators , dc leakage analyser , standard tool kit , relay tool kit , hv discharge rod and portable earthing equipment , hot stick upto 400 kv , multimeter analog,portable , portable digital ammeter ac , portable digital ammeter dc , portable digital voltmeter , portable dc earth fault leakage reactor , auto-transformer variac single phase , auto-transformer variac three phase , rheostat 50 ohm , 5a , rheostat 250 ohm , 1a , rheostat 1000 ohm , 1a , potential trf test set kit , crimping tool hand operated , crimping tool power operated , lcr meter bridge , battery impedance test equipment , ac clamp adapter , bench top digital multimeter , natural frequency tester , elcid- elec mag core impern detn kit , function generator , multifunction instrument calibrator , power quality analyser , meter test bench , surge comparison tester , sweep frequency analyser //bid details 2 / 50
Tender For provisioning of electrical and mechanical eqpt against ber under ge 862 ews - supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 300 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type(m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 450 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fitting & accessories e.g marking plate, lifting lugs, ci rollers, earthing terminals, cable box including suitable platform as reqd on site complete all as as specified & directed., supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 100 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type (m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 150 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fi