Tender For name of the work major overhauling of 02 nos kt1150 engines and 01 novt28 l engine cummin s make of san locomotives assisting for dismantling of kt1150 and vt28 l engines from the locomotives joint inspection of testing of overhauled engines shall be conducted between kpcl representative and firms representative joint inspection report of testing jirt after completion of re assembly shall be furnished to this office joint inspection of testing may be waived off at the discretion of the undersigned but the test report shall be furnished.removal and re installation of engine. this includes the complete procedure of safely removing the engine from the locomotive and, after completion of the necessary repair or overhaul work, re-mounting the engine back into the locomotive. all required tools, fixtures, lifting mechanisms, and safety measures shall be managed by the vendor.engine alignment process the alignment process involves precise positioning and securing of the engine to ensure correct interfacing with the locomotives drivetrain coupling systems, and support structures this includes, but is not limited to mounting of the engine onto the engine bed frame using proper alignment tools and calibrated instruments ensuring parallelism and angular alignment of the engine relative to the transmission or traction system verifying coupling concentricity and ensuring there is no misalignment that may lead to premature wear vibration or operational issues tightening of mounting bolts to specified torque values and rechecking alignment post tightening conducting necessary trial runs and adjustments if any to confirm proper functionality before final handover all the released items shall be returned in separate packing along with overhauled engines to kpcl
Tender For corrigendum : online tender for the rate contract for the supply of medical drug consumables to various hospitals of government of haryana for a period of two years for group c - cetrimide solution 20% conc. for dilution, 500 ml plastic bottle, i.o dye (rhex id dye) each (indigo blue dye), bed side pulley, disposable eye patch, potassium peroxomonosulphate 50% w/w containig aldehyde free disinfectant, 5 kg, bb splint (bohler- braun), ambu bag ped, it should be double layered resuscitator within built pressure limiting system that prevents airways pressure from exceeding 4 k pa ( 40 cm h2o without loss of valume. it should be supplied with reusable transparent breathing face mask , it should have tidal volume max 300 ml it should be usfda and iso/ce certified. (single unit), examination gloves (medium size), isi mark, carbolic acid 400 ml, dark eye glasses, pedeatrics iv drip set with air vent, sodium hypochlorite solution 10%, 5 ltr, chlorhexidine solution 5% conc. for dilution, 500 ml, bleaching powder containg not less then 30% w/w of avialble chlorine, 1kg, skin traction set standard size, gentian violet (methylrosanilinium chloride paint preparation aqueous solution 0.5%w/v), 50 ml dark bottle, hydrogen peroxide solution 6%, 400 ml bottle, disposable plastic urine pan, ambu bag adult, it should be double layered resuscitator within built pressure limiting system that prevents airways pressure from exceeding 7 k pa ( 70 cm h2o without loss of valume. it should be supplied with reusable transparent breathing face mask, it should have tidal volume max 1300 ml it should be usfda and iso/ce certified. (single unit), nitrous oxide inhalation, potassium permanganate crystal for solution 100 gm, balance salt solution (bss for eye surgery) 500 ml, patient identification band mother & child size (different colours), patient identification band paediatric size (different colours), medical x-ray films(1x50) 10"x12", medical x-ray films(1x50) 12"x15", patient identification band adult size (different colours), troponin t, sensitivity:-not less than 95.8%, direct whole blood test kit, disposable plastic bed pan, dj stunt, blades for eye surgery implant 5.2 mm, epidural set, posterior chamber pmma iol optical diameter 6mm, overall length 12.5 mm, optic design biconvex,360 degrees posterior square edge and uv protection should be there, dioptric range +23d, medical x-ray films(1x50) 8"x10", measured volume fluid infusion set with 110ml/150ml chamber -, posterior chamber pmma iol optical diameter 6mm, overall length 12.5 mm, optic design biconvex,360 degrees posterior square edge and uv protection should be there, dioptric range +22d, posterior chamber pmma iol optical diameter 6mm, overall length 12.5 mm, optic design biconvex,360 degrees posterior square edge and uv protection should be there, dioptric range +24d, chest tube with water seal no.32, dj stunt no 6/26 both end open, ecg roll big, posterior chamber pmma iol optical diameter 6mm, overall length 12.5 mm, optic design biconvex,360 degrees posterior square edge and uv protection should be there, dioptric range +17d, posterior chamber pmma iol optical diameter 6mm, overall length 12.5 mm, optic design biconvex,360 degrees posterior square edge and uv protection should be there, dioptric range +25d, dj stunt no.5.5, medical x-ray films(1x50) 14"x17", spc set (suprapubic catheter set), posterior chamber pmma iol optical diameter 6mm, overall length 12.5 mm, optic design biconvex,360 degrees posterior square edge and uv protection should be there, dioptric range +18d, dj stunt no. 6 french end closed, guide wire teflon coated j tip, ecg paper 60 mm* 15 mtr, roll, craner wire splint, ecg paper 50 mm*30 mtr, roll, dj stunt no 5/26 both end open, ecg paper 50 mm*20 mtr, roll, mr cannula no. 5, guide wire teflon coated v straight tip, skeletal traction, medical x-ray films(1x50) 14"x14", blades for eye surgery keratones 3.2 mm, acetone 400 ml, endotracheal tube, uncuffed no. 3.0 spec