Tender For supply of procurement of electrical safety item c c > f> f -pull cord rope 6 strands x 7 wires in each strand , pre start warning system with human voice for conveyor belt feeder breaker amplifier with speaker , led traffic signal light blinker or indicating lamp color red , siren for explosive van type battery operated suitable for auxiliary power outlet of vehicle, power supply 12v dc range 1. 5km minimum , siren for explosive van type battery operated suitable for auxiliary power outlet of vehicle, power supply 24v dc range 1 km minimum , industrial siren / electrical siren (q3)
Tender For supply of procurement of flp 3 point 3 kv vcb electoteknica switchgear make spares d d ? g? g -v0021 part no shunt trip coil assembly , v0022 part no electrical release coil assly , v0024 part no aux switch assy , v0042 part no push to trip assy , om009 part no operating mechanism , v0031 part no support insulator assy , v0048 part no vacuum interrupter , vfs0062 part no vacuum circuit braker assly vcb9576 , p0043 part no indicating lamp , p0045 part no trip neutal close switch , p0046 part no ammeter slashvoltmeter selection switch , p0047 part no earth leakage relay test reset switch , p0048 part no rectifier capacitor unit , i0038 part no isolator operating handle big andsmall , p0067 part no lt ct , p0061 part no auxiliary contactor 110 vac , p0049 part no earth leakage relay , fsv00104 part no ammeter , fsv00105 part novoltmeter , fsv00114 part no limit switch , fsv00110 part no ht hrc fuse for pt , fsv00116 part no control fuse 2dash10a , p0058 part no oil dash pot over load release , p0072 part no single core current transformer 10 va ct ) /bid number : gem/2026/b/7135223 * /dated: 24-01-2026 & & / bid document 1 / 25
Tender For supply of spares for mine line make acb and geb d d - isolator assly k3 on off part no 050000 , push button with spindle part no pbs , micro switch part no 50502 , shunt trip coil part no 110301 , no volt coil with moulding part no 110402a , no volt coil assembly under voltage coil part no 110400a , catcher assly part no 110531 , moving contact for breaker up to 200a part no 110206 , fixed contact breaker upto 200a part no 110604 , potential transformer part no ds , core balance transformer part no cbt150m , earth leakage relay 80 750 ma 0. 75 to 2a part no elm7dt , test resistance 2r56 part no 2r56 , terminal bushing with insulator dmc inco part no t55 , push button actuator for el test part no boes2 , push button actuator for el reset part no boes3 , brass terminal with dmc insulator part no r5 , restrained type plug and socket complete part no 010000 , auxiliary contactor part no boca2d1229 , thermal overload assembly part no 120021 , pilot relay part no pru3 , indicating lamp with pcb mounting part no lab9 , auxiliary contact 220v ac part no botcca
Tender For supply of procurement of spares of electroteknica make vcb d d -auxillary switch assembly, part no. v0024 , vacuum interrupter upto 800a, part no. v0048 , resin class ct class isp10 by ci10, part no. p0056 , electrical release coil assembly, part no. v0022 , push to trip assembly, part no. v0042 , indicating lamp, part no. p0043 , push button switch, part no. p0044 , ammeter voltmeter switch, part no. p0046 , potential transformer 11 kv by 110 v,100 va per ph, 3ph, part no. p0053 , control fuse 2-10a, part no. fsv00116 , idmt relay, part no. p0083 , earth leakage relay, part no. p0049 , vacuum circuit braker assly. 800a fbyt, part no. vfs0062 , ht hrc fuse for p. t. , part no. fsv00110 , isolator moving contact, part no. i0031 , isolator fixed contact, part no. fsi0032 , ammeter, part no. fsv00104 , voltmeter, part no. fsv00105 , shunt trip coil assembly, part no. v0021
Tender For corrigendum : tender for supply of push button with 1no or 1nc colour red , olr with builtin single phasing protec feature range 23 32a , indicating lamp suitable for 220v ac colour red , hrc fuse fittings 20a with 6a link , pin fulcrum link , key , contactor 40a with 3no 1nc coil voltage 220v ac , contactor 32a with 2no 2nc coil voltage 220v ac , indicating lamp suitable for 220v ac colour green , hrc fuse fittings 20a with 2a link , impeller , bush bearing nde , gasket , pump main bolt , impeller , bearing bush , pump shaft , bellow discharge , impeller , impeller , shaft pump , shaft pump , impeller , de bearing 6208 2z , fuel piping imperial , contactor rated 18a 220v 1no 1nc , contactor rated 12a 220v 1no 1nc , seprator filter water separ , 3 8 od x 5 mtr copper tube , air impeller , impeller , shaft , wearing ring impeller , shaft , impeller , aux contactor , over loard relay , gauge pressure with cock 0 to 6kg gm2 , tie bolts nut , set screw mechanical seal , tie bolts nuts , contactor 70a tp with 2no 2nc aux contact , shaft , shaft sleeve , vacuum breaker , 2 way pn valve 1 1 2 , ball valve 1 1 2 pvc threaded , activator , pump evac se 044a vem motor , seat and cover with hinges , seat and cover toscana , plug , pin suction scanner handle , fuse 20amp , rotor , complete blower with motor , relay control 4pole 14pin 120vac coil lighted , mechanical seal , o ring , coupling pad , seal mechanical , mechanical seal , mechanical seal assly , mechanical seal assly , bi metal thermal 5point5point8a over load relay , i l flexible hose w flange , o l flexible hose w flange
Tender For corrigendum : tender for supply of clip on type terminal station , auto change over switch 250a , cam type single pole on-off switch 10amps , 1s160 , triple pole moulded case circuit breaker 100amps , hcos 100a for emergency operation(ex.)if envisaged in sotr , illuminated push button green , cam type selector switch 2p 2 way with off 10a , hrc fuse link rated 100a , fuse link 2amps , helo starting cable with nato end connectors (21 meters) , mccb 630a , type lm 630b , make e , 3 pole mccb 32a -nsx100f , mcb 250a with micrologic 2.2 trip unit(lv431770) , tp mccb rated 50a , single pole nine way without off rotary switch rated 16a , contactor 110a t.p.(contact kit) , aux contact.base block ( 1 no+1nc) for 110-a t.p. , fuse 32a fitting hrc , unshourded pushbutton 1no+1nc with yellow colour lens(pmt1ab , illuminated pushbutton integral led 230v red , add on 1no contact , d.p miniature circuit breaker rated 16a , terminal , conventional fire detection panel 4 zones , on delay electronic timer ac 110-240v having range 1-30s , 230v ac relays 4 c/o with led and base alonwith clamp , tp mcb 63a(c60h 3p 63a c) , ammeter 0-1000a , rm-800a , ctr 1000/5a , 96x96 cl1 acc 900 scale , hrc fuse fittings rated 20a (3nw20nnsf) , hrc fuse link rated 6a(3nwns6) , hrc fuse fitting rated 20a (3nwns10) , insulation monitoring relay 115v 3ph 400hz (vtv-02) , ammeter 0-200a ctr 200-5a , 400hz acc cl-1 , 96x96 rm at 150a , kilowatt meter 120-0-750 kw size 96x96mm , frequency meter 55-60-65hz 440v , size 96x96mm rm at 60hz , 1 watt , 24v dc/ac , led bulb , milky white of e27 thread type , 1 watt , 230v ac , led bulb , milky white , of e27 thread type. , breaker 25a , dp mcb , step down transformer 20kva , 380 230v , 3ph , 50 hz star-delta , smoke detector tester gas bottle - solo , main processor unit , navigation lamp 65w 230v (per yard) , under voltage coil 230 , 50/60 hz , hrc fuse fitting with fuse link rated 4amps , hrc fuse fitting with fuse link rated 2a , 3 pole mccb , 100amps , 36ka , schinder make , phase sequence indicator 50-500v , 96x96mm cl1 acc 900 scale , kw mtr 15-0-150kw , ctr 2005/5a , rm at 80kw , 415v , 3p , 2 ele 96mm , generator protection unit415v , 3ph , 50hz , load sharing unit mv av 380v , 50hz , 3ph , ctr 250 5a , m340-discrete outputs-modicon m340 discrete dc output , indicating lamp integral led white colour , 24v ac/dc , indicating lamp integral led green colour , 24v ac/dc , indicating lamp integral led green colour 230v , contactor 800a dc , 28v coil with 1no/1nc aux. contact
Tender For corrigendum : supply and installation of ip54 protected glass fiber reinforced polycarbonate double insulated power distribution board of dimension 1200 x 1300 x 274mm. the enclosure must be of double insulated, haloge free with high impact resistance of ik08 (5 joules) according to iec 62262. the enclosure should be made of uv resistant material, corrosion free. the enclosure material used should be self-extinguishing up to 960 deg with working temperature from -35 degc to +80 degc. interconnection between the enclosures in the panels should be made with accessories which should maintain with same ip protection rating of ip65. the enclosure gasket materials shall be injected polyurethane. the enclosure should be made of the same polycarbonate materials only. incomer: 400a fp mccb 36ka - 1 no and 230v ac r,y,b indicating lamp, digital multi-function meter with 400/5a current transformer and outgoing: 100a tp mccb 36ka with 100a neutral link - 7 nos & 63a fp mcb 10ka - 2 nos with 70a tp ac3 contactor control with 24hrs digital timer with auto/manual selector switch and push buttons for manual operations .copper busbar rating of 400a - 30 x 10 for all phases and neutral should be used -provision for termination of 185 sq.mm in incomer and 35 sq.mm cables for 100a outgoing, 16 sq.mm cables for 63a outgoing and all mccb should have an adjustable setting range (in) from 70% to 100%, each mccb should have extended rotary handle for easy operation. the manufacturer should submit all the test certificates in accordance with iec 61439, routine test report must be made with high voltage test, insulation resistance test, functional test. the wall mounting frame should be made of hot dip galvanized materials. 1) acceptable make :cape/ famatel/hensel/rittal/abb with following switch gear and terminals fixed in the junction box as per drawing enclosed. 2)terminal block make: connect well/ elmex. 3)switch gears make shall be abb/l&t /eaton/siemens,havells,c&s. [ warranty period: 12 months after the date of delivery ]