Get complete information related to latest Enclosure Wall Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Enclosure Wall Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Enclosure Wall Tenders.
Tender For construction of pcc road,and guard wall from house of nazir sheikh to house of serajul sheikh at village hariganj panchayat gandhaipur, block pakur, district pakur
Tender For r/r damages to patta joharji sua road in km. 0/00 to 13/00.(sh construction of r/wall in wire crates pcc b/wall at various rds. repair of catch pit and improvement and strengthening of damaged portion of road by providing gsb, g-iii, prime coat, tack coat, 30mm
Tender For implementation of various developmental works (3 nossubmersible pump, pcc road, 2 nospccdrain,gurd wall) at polling station no 15 under rajgram gp under murarai i dev. block under the fund-apas-2025-26
Tender For construction of concrete guard wall with pcc road from sk abidul islam house to sahadath mallik at denan jl no 291 plot no 392 within kolaghat panchayat samity from 15th fc fund 2025 2026 2nd inst. ac no 109592518
Tender For corrigendum : repairs to pcc hard standing near dispersal and access pathway of runway, desilting of drain, repair to damage wall, surface channel, drain covers, painting to runway, turning pad and miscellaneous repairs works at shibpur under ge s diglipur
Tender For improvement of approach area including casting of pcc and heightening of brick drain wall and including stteel staier case at ccd complex 79 till agartala
Tender For corrigendum : supply of stores at for, shifting of store from for to worksiteand construction of ug comd bunker of size 5.30m x 5.15m x 2.40m (floor levelto roof level) with rcc wall cum brick wall in 1:6 cement mortar, srt roof overismb with ohp, rcc floor over pcc sub base with vitrified tiles flooring, pvcfluted panel false ceiling with 0.75m wide verandah alongwith brick partition oftoilet block of size 1.20m x 3.01m x 2.40m
Tender For provn of dry ration stores under ge 881 ews - sch a part-i (building work):-this schedule is not pre-priced by mes and the pre-priced rate indicated as "rs. 0.00" under col.5 signifies this fact only., construction of block of storage shed complete all as shown on drawings and as specified., total amount of sch a part - ii (site clearance/development work), total amount of sch a part - iii (internal electric supply work), total amount of sch a part - iv (protective work), total amount of sch a part - v (area drainage work), total amount of sch a part -vi (road, path and culvert work), total amount of sch a part -vii (external electric supply work), total amount of sch a part -viii (demolition/dismantling work), sch a part - ix (misc items of work) note : this schedule is not pre-priced by mes and the pre-priced rate indicated as "rs. 0.00" under col.5 signifies this fact only., double walled corrugated (dwc) pipe for cable protection with outer dia 50mm and inner dia 38mm including suitable size of coupler for connection of pipe complete all as specified and directed., point wiring for one light/fan point/call bell point controlled by one way switch 5 amp with 1.5 sqmm single core multi standed copper conductor frlsh insulated and unsheathed heavy duty cable in colour code including earth wire with cable of size 1.5 sqmm copper conductor frlsh insulated, drawn into and including concealed in pvc conduit of not less than 20mm dia and 1.5mm wall thickness (isi marked) terminated into annealed steel terminal boxes including modular plate and cover for mounting modular switch/ socket switches, sockets, fan regulators etc complete all as specified and directed., all as per srl item no. 12.00 above but for one 3 pin 5 amp socket on same board., all as per srl item no. 12.00 above but for one 3 pin 5 amp socket on independent board., earthing complete with galvanized steel earth plate electrode 600x600x6mm burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia gi light grade protection pipe, 20mm dia gi medium grade watering pipe with funnel including charcoal, dust, salt, pcc m-15 type b1 in pit with angle iron (25x25x3)mm frame work with precast rcc 1:2:4 type b-1 cover reinforced with 8mm dia tmt bars @ 150mm c/c both ways and 12mm dia ms fabricated handle, test point etc. in and including light grade gi protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate no. 3 of ssr part-i complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.note:- on testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction., inverter led light fittings batten type, 1x20w led, 230v, complete with all accessories internally per wired including lithium lon battery with charging time 8 to 10 hours and back up time up to 4 hours and connecting up with pvc insulated and sheathed, 1100 v grade, flexible, multistranded copper conductor three core cable complete all as specified and directed., led street light/ security light fitting 35 watt, 230 v, ac, outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 66 protection, including provision of gi bracket made of 40mm dia, gi pipe, 1.5m long, bend to shape, complete all as specified., mcb, spn, 240 volts, 40 to 63 amps,10ka, breaking capacity, complete all as specified., mcb, spn, 240 volts, 6 to 32 amps,10ka, breaking capacity,
Tender For c/o fis koil kuhal in gp gadej damaged during 2023-24 (under pdna) (sh:- c/o main channel over rcc columns at ropdu nallah = 15 mtrs., c/o main channel on gl behind rd 50 to 80 =30 mtrs, c/o pcc retaining wall with skin reinforcement from rd 50 to 80 = 30 mtrs).