Tender For tender for supply of safranine staining solution 125ml , compound microscope with led lamp , cotton blue 25gm , slides boxes for 100 slides , specimens , cover slips box english glass 22x22 square , inoculating loop , bunsen bumer , spirit lamp , binocular microscope , crystal violet 125ml , gram iodine stain solution 125ml , potato dextrose agar , ethanol , herbarium sheets 50 pieces , stopwatch or timer , balance scale digital balance 2 digit , scissors or pruning shears , calipers digital , weighing machine digital balance 3 digit , fast green 125ml , xylene ar 500ml , dpx mountant for biochemistry 250ml , balsam canada 100ml , glycerine 500ml , watch glass 4inch dzn , oven , incubator 14x14 , refrigerator , magnetic stirrer with hot plate , ph stips box , cavity tile 12 cavity , ph meter lt-10 , deep freezer 300 ltr , centrifuge machine 6000 rpm , digital colorimeter , ocular micrometer , stage micrometer , scalpel , razor blade , fine forceps , stirring rod , vorter mixer , graduated pipettes , droppers , test tubes 15x125 box , test tube rack -16mmx60tubes , beakers 250ml , hemocytometer , water bath 12 hole digital , chemicals all x 25 , extra preserved speceimen , digital balance 2 digit , digital balance 3 digit , digital ph meter with electrode , digital photo colorimeter , water distillation plant , heating mental with regulator 500 ml , hot air oven , test tube , beaker 250ml , beaker 500ml , conical flask 250ml , conical flask 500ml , chemical thermometer , round bottom flask 250 ml , measuring cylinder 50ml , measuring cylinder 100ml , filter paper , burette 50ml , pipette 25ml , bloating paper , flame photometer , electrical conductivity meter , specific gravity bottle , desiccators , digital melting point apparatus , stalgnometer , viscometer , digital potentiometer with electrode , kipps apparatus , spectrophotometer , polarimeter , weighing bottle , volumetric flask 250ml , buchner funnel , separating funnel 250ml , whatman filter paper , petridisc , mortar and pastel , digital multimeter of big display , dc voltmeter 0- 25volts , dc voltmeter 0-10volts , dc multimeter 0-25ma , dc ammeter 0-3amp , newton ring complete set with transformer , mercury lamp with transformer , determination of young modulus of a wire by optical lever method , rc coupled amplifier experiment trainer board , dual power supply , calender and barne constant flow method , digital oscilloscope dso , meter bridge of good quality , plane diffraction gratting , bar pendulum , kater pendulum , optical bench , de sauty bridge set up , potentiometer , to show the tunneling effect in tunnel diode , b-h curve of fe using solenoid and determine energy , copper connecting wires , vernier callipers , prism , fractional resistance , determination of moment of inertia of a flywheel , meter scale , capillary tube , key 1 way or 2way , spectrometer , thermocouple trainer kit , spirit level , plank constant photo electric cell set up with filters , 8085 microprocessor , opamp , tuning fork , series and parallel lcr circuit , compass needle , two junctions of a thermocouple with temperature , solar and photo cell characteristics kit vi , bar magnet , verify the malus law for plane polarized , function generator 1mhz , screw gauge , travelling microscope , rheostat , sextant for height measurement , stop watch , solenoid , p-n junction diode characteristic apparatus , resistance box , zener diode , diffraction grating with 1500 lpi , he-ne laser , sodium lamp with vertical box , convex lens , concave lens , plano convex lens , acordc battery eliminator , breadboard , jumper wires for breadboard , hall effect set up , four probe complete set up , gm counter , compound microscope , autoclave 50 ltr , incubator , ph meter , digital colony counter , vortex shaker for test tube , water bath digital , haemocytometer , haemoglobinometer , plankton net and collection vial , gel doc , electrophoresis , electrophoresis power supply , microtome blade , microtome ,
Tender For supply of digital multimeter of big display , dc voltmeter 0-25volts , dc voltmeter 0-10volts , dc multimeter 0-25ma , dc ammeter 0-3amp , determination of wavelength sodium , mercury lamp with transformer , determination of young modulus of a wire , rc coupled amplifier experiment trainer board , dual power supply , calender and barne constant flow method , digital oscilloscope dso , meter bridge of good quality , plane diffraction gratting , bar pendulum , kater pendulum , optical bench , de sauty bridge set up , potentiometer , to show the tunneling effect in tunnel diode , to draw the b-h curve of fe using solenoid , copper connecting wires , vernier callipers , prism , fractional resistance , determination of moment of inertia of a flywheel , meter scale , capillary tube , key 1 way or 2way , spectrometer , thermocouple trainer kit , spirit level , plank constant photo electric cell set up , 8085 microprocessor , opamp , tuning fork , carry foster bridge , series and parallel lcr circuit , compass needle , study of variation of thermo emf across two junctions , solar and photo cell characteristics kit , bar magnet , verify the malus law for plane polarized , function generator 10mhz , screw gauge , travelling microscope , rheostat , sextant for height measurement , stop watch , solenoid , p-n junction diode characteristic apparatus , resistance box , zener diode , diffraction grating with 1500 lpi , digital balance 2 digit , digital balance 3 digit , digital ph meter with electrode , digital photo colorimeter , centrifuge machine 6000 rpm , water distillation plant , magnetic stirrer with hot plate , heating mental with regulator 500 ml , hot air oven , refrigerator , test tube , beaker 250ml , beaker 500ml , conical flask 250ml , chemical thermometer , round bottom flask 250 ml , measuring cylinder 50ml , measuring cylinder 100ml , filter paper , burette 50ml , pipette 25ml , bloating paper , flame photometer , electrical conductivity meter , specific gravity bottle , desiccators , digital melting point apparatus , stalgnometer , viscometer , digital potentiometer with electrode , kipps apparatus , compound microscope , binocular microscope , autoclave 50 ltr , incubator , deep freezer 300 ltr , digital colorimeter , ph meter , digital colony counter , vortex shaker for test tube , water bath digital , inoculating loop , bunsen burner , spirit lamp , soil thermometer , anemometer , lux meter , haemocytometer , haemoglobinometer , plankton net and collection vial bid details/ 2 / 91
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s
Tender For corrigendum : supply of medical equipments in various locations in distt. patiala (as per detail attached) - supply, ot table, hydraulic operated with smooth gear mechanism, double cylinder loak proof, stainless steel, medical refrigerator 250-300 ltr. with shelf temperature setting (approx) +0 to +8 c, voltage 220 - 240 v, freguency 50/60 hz, ot light ceiling mounted single dome 12 led with led 50000 lux 22" dia dome with 4 reflector of 8 dia. auto spring balanced, heavy duty step down transformer. sterilizable central handle., ecg machines 12 leads single print 10-hour standby time, continuous print more than 3-hour, auto-analysis and auto-diagnosis for routine ecg parameters, built-in large capacity memory, casseta 14*x17* for pre-installed dr system for xray at mkh patiala make agfa, semi auto analyzer with built in software for the calculation and curve plotting. light source led, open system capable using all grand reagents and all the test programs should be in open mode. user interface: lcd display with touch key board, flow cell type permanent flow cell. memory >= 500 tests, in-built thermal printer, in-built thermal printer required, accessories to be supplied 1. micro pipettes (* no.) - 2 variable (5-50), (100-1000), small tips 500 nos. & large tips- 500 number, laproscopic surgical instrument set, ups 1kva offline for ultrasound machine simulated sine wave or better voltage avr mode 200-245v voltage battery mode 230vac +10%e frequency (htz) on battery 50/60hz + 0.1hz, 30 min backup, iso 14001/bis certification, biphasic defibrillator monitor 8.4" inch size screen, charging time of less than 9 seconds for maximum energy of 2 to 360 joule, synchronized & asynchronized cardio-version and having in-built thermal printer, monitoring 12 lead ecg, heart rate, spo2, & nibp, 230v, 50hz ac mains and battery capable of delivering up to 50 shocks at 200 joule, iso /en 60601-1, certified, oem warranty 3 year, boyles apparatus, 4 cyl mechanical with 3 gas system with hypoxic guard with 2 vaporizer (halothane & isoflurane), ice lined refrigerator (ilr) 144 lt 220 volt 50 hertz, in build stabilzer led (3-digit digital display), galvanized steel, stem alchol thermometer, ground clearance (min) 100 millimeter, holdover time (in a continuous external temperature of +43 degree celsius -24 hour, sets of instruments used for laparoscopy surgerya. gull bladder extractor, b. call stone spoon extractor c. 10 mm safety trocar, d. aspiration needlee. 5mm and 10 mm reducers, metallic continuous spray pump 1.5 ltr. (ganesh pump) type: hand compressor sprayer, tank: brass. tank capacity: 1.5 lit. pump barrel brass, working pressure, 40 - 45 psi, baby warmer steel tubular structure pretreated and powder coated heater rotation +90, bed tilt should be 615 , led displays, aulomatically cut off at 38 degree celsius, probe accuracy specilication: +0.1 c @ 30 c to 42 c, 200 to 240vac 50 hz supply
Tender For weighing machine digital weighing scale capacity 500 kgs, accuracy 50 gram, checker plate top size 600 mm x 600 mm approx., red bright led display, 6v, 4ah, rechargeable smf battery operated a nd single phase 90 volt to 250 volt, 50 hz electric operated, structure made from 50mm square heavy pipe, supply with calibration certificate from government approved agency. make tula, tanita, stenling, adorin, ritco, phoenix or similar. ]