Get complete information related to latest Ethidium Bromide Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ethidium Bromide Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ethidium Bromide Tenders.
Tender For empanelment for the supply of cathlab items on running contract basis under kasp and other schemes of this hospital - coronary stents, des,everolimus,fda/dcgi/ce approved platinum chromium platform,polyvinylidene fluride-hexafluropropyline pvdf-hfp polymer-stent lengths8,12,16,24,28,32. stent diameter 2.25*,2.50,2.75,3.00,3.50,4.00.struct thickness 81/86 microns.nominal pressure - 11 atm,rated burst pressure 16-18 atm, des,everolimus,fda/ approved platinum chromium platform,polyvinylidene fluoride-hexafluropropylene(pvdf-hfp)polymer, des,everolimus,fda/dcgi/ce/ approved platinum chromium platform,bioabsorbable polymer plga, everolimus eluting platinum chromium stent system, des, everolimus, l 605 cobalt chromium with hybrid cell design , strut thickness- 65microns, polymer- plga diameter- 2.25, 2.5, 2.75, 3.0, 3.5,4. length- 10,13,15,18,20,24, 28, 32,36,40, 42, 44, des, everolimus, cobalt chromium strut thickness - 63 microns . diameter- 2.25,2.5,2.75,3,3.5,4. length- 8,10,13,15,18,20,24,28,32,36,40,42,44. elutes 80% of drugs along with re plga polymer in the first 20 days, dcgi approved everolimus drug eluting 65 micron strut thickness with 3 micron plla&plga. a unique proprietory coating technology basedbiodegradable polymer stent with open cell designed and flexia finished technology based cobalt chromium l605 stent.a designed for optimal strength, flexibility ,trackablity ,side branch supported,bifurcation supported and high radial strength and optimal radiopacity and excellent vessel supported stent with revers alternative link design(ral) stent, with length from 8 mm to 52 mm and diameter from 2.25 mm to 4.50 mm, ce approved everolimus eluting coronary stent system struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 degree with respect to different diameter. the cells are connected by link (mid to mid pattern) with a radius of 0.2700mm. these values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. components - drug: everolimus, stent platform: cobalt chromium l605 alloy, polymer: biodegradable, catheter: ptca rapid exchange semi-compliant stent delivery catheter. drug concentration: 1.2 microgram/mm2 of stent surface area. stent diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & stent length (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47 platinum-iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, also the difference between stent edge to marker is 0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty., ce approved sirolimus eluting coronary stent system struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 degree with respect to different diameter. the cells are connected by link (mid to mid pattern) with a radius of 0.2700mm. these values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. components - drug: everolimus, stent platform: cobalt chromium l605 alloy, polymer: biodegradable, catheter: ptca rapid exchange semi-compliant stent delivery catheter. drug concentration: 1.2 microgram/mm2 of stent surface area. stent diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & stent length (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47 platinum-iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, also the difference between stent edge to marker is 0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty., only dcgi approved everolimus eluting coronary stent system struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 deg
Tender For request proposal for supplying various chemicals and reagents in 15 nos.of water testing laboratories under dw and sd, jharkhand dumka zone - turbidity (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) - 400 ntu-standard 100 ml/bottle iso- 17034 certified, potassium chloride (kcl)-500gm/pkt, cone. sulphuric acid-(ar grade)-500ml/bottles, ph buffer solution (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 4.01-(500ml/bottle) iso-17034 certified, ph buffer solution (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 7.00-(500ml/bottle) iso-17034 certified, ph buffer solution (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 9.18.00-(500ml/bottle) iso-17034 certified, sodium carbonate (na2co3) (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 80 grm/pkt iso- 17034 certified, calcium carbonate (caco3) (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 50 grm/pkt iso- 17034 certified, sodium standard solution -1000 ppm (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 500ml/l iso- 17034 certified, potassium standard solution -1000 ppm (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 500ml/l iso- 17034 certified, copper standard solution -1000 ppm (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 500mi/i iso-17034 certified, sodium chloride (nacl) (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 80 grm/pkt iso-17034 certified, potassium chloroplatinate 500ml/bottle (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) iso-17034 certified), nitrate standard solution 1000ppm (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 500ml/bottle iso-17034 certified), iron standard solution 1000ppm (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 500ml/bottle iso-17034 certified), arsenic standard solution 1000ppm (crm must be nist traceable with uncertainty of measurement (uom)validity period at least 2 years with certificate) 500ml/bottle iso-17034 certified), colour standard500 pt-co units (crm/srm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate 500 ml/bottle 17034 certified), sulphate standard 1000ppm ((crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 500ml/bottle iso-17034 certified), mixed standard for icp-oes machine (multi elements that essentially include-al, as, fe, fl, cd, co, pb, mn, ni, z, crm-1000ppm iso-17034 certified-500ml/bottle, fluoride standard solution 1000ppm (crm must be nist traceable with uncertainty of measurement (uom)validity period at least 2 years with certificate) 500ml/bottle iso-17034 certified), total dissolved solids 1000ppm (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 500ml/bottle iso-17034 certified), conductivity standard solution 1.41 ms/cm (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 500ml/bottle iso-17034 certified), methyl orange solution 125 ml/bottle, bromocresol green indicator 125 ml/bottle, phenolphthalein green indicator 125 ml/bottle, sodium hydroxide 500 gm/pkt, edta salt 50
Tender For request proposal for supplying various chemicals and reagents in 16 nos.of water testing laboratories under dw and sd, jharkhand ranchi zone - turbidity (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) - 400 ntu-standard 500 ml/bottle iso- 17034 certified, potassium chloride (kcl)-500gm/pkt, cone. sulphuric acid-(ar grade)-500ml/bottles, ph buffer solution (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 4.01-(500ml/bottle) iso-17034 certified, ph buffer solution (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 7.00-(500ml/bottle) iso-17034 certified, ph buffer solution (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 9.18.00-(500ml/bottle) iso-17034 certified, sodium carbonate (na2co3) (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 80 grm/pkt iso- 17034 certified, calcium carbonate (caco3) (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 50 grm/pkt iso- 17034 certified, sodium standard solution -1000 ppm (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 500ml/l iso- 17034 certified, potassium standard solution -1000 ppm (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 500ml/l iso- 17034 certified, copper standard solution -1000 ppm (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 500mi/i iso-17034 certified, sodium chloride (nacl) (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 80 grm/pkt iso-17034 certified, potassium chloroplatinate 500ml/bottle (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) iso-17034 certified), nitrate standard solution 1000ppm (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 500ml/bottle iso-17034 certified), iron standard solution 1000ppm (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 500ml/bottle iso-17034 certified), arsenic standard solution 1000ppm (crm must be nist traceable with uncertainty of measurement (uom)validity period at least 2 years with certificate) 500ml/bottle iso-17034 certified), colour standard500 pt-co units (crm/srm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate 500 ml/bottle 17034 certified), sulphate standard 1000ppm ((crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 500ml/bottle iso-17034 certified), mixed standard for icp-oes machine (multi elements that essentially include-al, as, fe, fl, cd, co, pb, mn, ni, z, crm-1000ppm iso-17034 certified-500ml/bottle, fluoride standard solution 1000ppm (crm must be nist traceable with uncertainty of measurement (uom)validity period at least 2 years with certificate) 500ml/bottle iso-17034 certified), total dissolved solids 1000ppm(crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 500ml/bottle iso-17034 certified), conductivity standard solution 1.41 ms/cm (crm must be nist traceable with uncertainty of measurement (uom) validity period at least 2 years with certificate) 50ml/bottle iso-17034 certified), methyl orange solution 125 ml/bottle, bromocresol green indicator 125 ml/bottle, phenolphthalein green indicator 125 ml/bottle, sodium hydroxide 500 gm/pkt, edta salt 500
Tender For name of workgarhi padla- water supply scheme for installation of 1 no. new tubewell against abandoned tubewell no. 1 (due to excess sulphate as so4 and fluoride as f found(mg/lt) at village garhi padla tehsil and district kaithal providing and installing 1 no. tubewells in village garhi padla of size 250mm x 200 mm upto 400 meters depth below ground level respectively by reverse rotary rig and all other works contingent thereto according to isi specification no. 2800-1991 (part-i) and is 2800-1979 (part-ii) as amended upto date