Tender For corrigendum : repair maintenance to lt panels lt ug cables earthing allied lt maintenance works internal wiring fittings and fixtures rewinding of ceiling exhaust fans geysers and cooling appliances dg sets lightning protection street lights and external water sup
Tender For corrigendum : repair maintenance to internal wiring fittings and fixtures rewinding of ceiling/exhaust fans geysers and cooling appliances dg sets lightning protection street lights and lt panels lt ug cables earthing allied lt maintenance works and external water
Tender For corrigendum : repair /maint of ac plant, chillers /condenser motor, cooling tower, descaling of condenser and other related works at ge (af) suratgarh
Tender For addanki municipality - providing lab equipment in computer science engineering lab at government polytechnic college, addanki under mplads 2024-25 - 1.8/1.9/2.0tr, 3 star capable of delivering not less than 21600 btu/hr and above with operating on refrigerant r-410a / r-32 makes: as per list of recommended brands as category i. , 6 utp cable , computer science engineering lab , computer science engineering lab , computer science engineering lab , computer science engineering lab , computer science engineering lab , computer science engineering lab , computer science engineering lab , computer science engineering lab , computer science engineering lab , computer science engineering lab , computer science engineering lab , computer science engineering lab , providing independent earthing from main switch board for earth continuity with no.8, g.i wire including excavation of earth in hard gravel/hard desintegrated rock upto 2.10 mts.' depth below ground level of section 5'x2'x3' duly providing 40mm dia g.i pipe of 2.50 mts. length using gi bolts and nuts and fixing earth wire including supply and fixing 18''dia., 2" thick hume pipe ring and refilling the pit with 5 kgs hard coke, 20kgs salt and excavated earth including all labour charges etc., complete for finished item of work. , supply and delivery of chairs for the the lab arrangement including transportation,labour,.. complete as per direction of departmental authoritis,ect completed.rate adopted from the local quotation. , supply and delivery of tables for the the lab arrangement including transportation,labour,.. complete as per direction of departmental authoritis,ect completed.rate adopted from the local quotation. , supply and fixing of 12v 42 ah smf battery with 3 years warranty including wire leads, connections etc complete. makes: as per list of recommended brands. mat-04553 , supply and fixing of 16-a/6a 1 way combi socket with shutter make of legrand arteor/schneider zen celo/honeywell blenge plus duly recessed in module box including cost and conveyance of all materials to work site and all labour charges etec.,complete. , supply and fixing of 6-a/10-a 3/2 pin 2 module modular socket with shutter of make legrand arteor/schneider zen celo/honeywell blenge plus with 6-a/10-a, 1 way 1 module modular switch of make legrand arteor/schneider zencelo/ honeywell/blenge plus 6-a switch control on a common switch board of with earth continuity including wire leads, earth connections along with all labour charges etc., complete. , supply and providing of battery rack upto 11 to 20 batteries (42 ah) , supply installation testing and commissioning of 10 kva on line ups system confirms to is 16242(part-i):2014 and iec 60240-1: 2008 with igbt technology pure sine wave output, double conversion with auto and manual static by pass switch single phase input / single phase output. makes: as per list of recommended brands. , supply installation testing and commissioning of 4 pair 24awg cat-6 utp, flexible, double ended patch cords lszh along with 2 nos of rj 45 connectors with strain relief boots compatible to t568a, t568b specifications including making connections to information outlets makes: as per list of recommended brands as category ii. , supply installation testing and commissioning of1no of cat6 tool less built-in crimping mechanism information outlet with dust cover exceed ansi/ tia-568-c.2 and iso/iec 11801 standards with 1module face plate for category 6 component performance & compatible to t568a, t568b wiring pattern and ul-940v0 rated plastic &rohs compliant makes: as per list of recommended brands as category i. , supply of ...............inverter model cool type split ac unit with high wall mounted single split indoor unit and outdoor condensing unit hermetically sealed compressor suitable for operation on 230v, 50hz, 1phase ac supply capable of performing heat cool dehumidifying air circulating and filtering with cooling and condensing units with 3 mts of c
Tender For supply, installation, testing, commissioning, and user training of a scalp cooling system at iisc, bangalore. the system shall provide precise, uniform, and stable scalp temperature control for use during pre-chemotherapy, during chemotherapy, and post-chemotherapy phase ensuring effective scalp cooling, patient safety, clinical reliability, and ease of operation for healthcare professionals.
Tender For renovation upgradation of 01 no 120 men jawan barrack no 2 of 138 bn now 115 bn bsf under shq bsf asr sh 2 p f duct cooling system - renovation/upgradation of 01 no 120 men jawan barrack no.2 of 138 bn (now 115 bn ) bsf under shq bsf amritsar (sh:2 p/f of duct cooling system)