Web Analytics Made Easy - StatCounter

Explosive Trace Detection Machine Tenders

Get complete information related to latest Explosive Trace Detection Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Explosive Trace Detection Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Explosive Trace Detection Machine Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40841890 Due date: 18 Jul, 202518 Jul, 2025 NA
Tender For supply and installation of laboratory equipment experimental setup for fyimp ug practical classes at the department of physics, gauhati university - laboratory equipments/experiment set ups, experiment name: to verify the law of malus for plane polarised lighttechnical specifcations:i. light source: - led: 532 nm or 635 nm ( 2 nm stability), 1 5 mw adjustable output. - unpolarized (extinction ratio >500:1). - collimated beam (divergence 0.5 mrad); qty-1ii. polarizers- glan-thompson or polymer film. - extinction ratio 10 :1 @ operating wavelength.- mounted in 50 mm rotation holders.; qty-2iii. rotation stage- motorized analyzer rotation (0.05 resolution). - accuracy: 0.1 . - range: 0 360 (continuous).; qty-1iv. photodetector- silicon photodiode (400 1100 nm). - linearity: r 0.999 (0.1 w 5 mw).- digital readout: 0.1 w resolution.; qty-1v. optical bench-- anodized rail ( 60 cm) with kinematic mounts. - vibration-damping feet.; qty-1, experiment name: to determine thespecific rotation of sugar solution using polarimetertechnical requirementsa.core instrumenti. light source- - sodium d-line (589.3 nm) or tunable led ( 2 nm stability). - output stability: 0.2% drift/hour.ii. polarizer/analyzer- glan-thompson prisms or high-grade polymer film. - extinction ratio 10,000:1 at 589 nm.iii. rotation stage- motorized with 0.001 resolution.- accuracy: 0.005 .- range: -90 to +90 .iv. sample cell-- borosilicate glass tubes with precision ground ends. - path lengths: 0.5 dm, 1.0 dm, 2.0 dm ( 0.01 dm tolerance). - temperature-controlled jacket (5 50 c 0.1 c).v. detector- photomultiplier tube (pmt) or low-noise photodiode. - linearity: r 0.999 over 0.1 w 5 mw rangevi. enclosure- light-tight with vibration damping. - internal black anodized surfaces.b.measurement specificationsi. specific rotation: range: -180 to +180 resolution: 0.001 accuracy: 0.01 ii. concentration-range: 0.01 0.5 g/ml (sucrose in water) detection limit: 0.001 g/mliii. temperature control-stability: 0.1 c at 20 c (standard condition), experiment name: to determine the wavelength and velocity of ultrasonic waves in a liquid (kerosene oil, xylene, etc.) by studying the diffraction through ultrasonic gratinga.core componentsi. ultrasonic generator- - frequency range: 1 10 mhz ( 0.1% stability). - adjustable output: 0 50 w. - digital display (resolution: 0.01 mhz).ii. transducer- piezoelectric (pzt) crystal, resonant at 2 5 mhz. - liquid-coupled design for efficient energy transferiii. liquid cell- optical glass (low thermal expansion). - dimensions: 100 50 50 mm (l w h). - sealed with quartz windows.iv. light source- he-ne laser (632.8 nm, 2 mw) or sodium lamp (589.3 nm). - beam collimation: 0.5 mrad divergence.v. optical system- adjustable slit (10 500 m). - collimating lens (f = 150 mm, 50 mm). - precision rotation stage for detector (0.01 resolution).vi. detection system- photodiode/pmt detector with linear response (400 800 nm). - traveling microscope (0.01 mm resolution) or ccd camera ( 5 mp).b.measurement specificationsi.wavelength ( )range: 0.1 2 mm, resolution: 0.001 mm, accuracy: 1%ii. velocity (v)range: 800 2000 m/s (liquids) resolution: 1 m/s accuracy: 2%iii. diffraction angles- measurement range: 30 resolution: 0.01 , experiment name: to verify the stefans law of radiation and to determine stefan s constanta.core componentsi.black body radiator- cavity-type design (emissivity 0.99). - material: nickel-plated copper.- operating range: 50 c 600 c. - aperture diameter: 10 mm 0.1 mm.ii. heating system- pid-controlled furnace (0 600 c). - stability: 0.5 c at 300 c. - power: 500 w (ac 230v).iii. temperature sensor- type k thermocouple or pt100 rtd. - accuracy: 0.5 c at 500 c (nist-traceable).iv. radiation detector- thermopile sensor (spectral range: 0.3 20 m). - responsivity: 10 v/w.- active area: 10 10 mm .v optical path. - water-cooled collimating tube with baffles.- adjustable aperture to define solid angleb.measurement specificationsi. temperature range100 c 500 c (reso

Central Government/Public Sector

CTN :40812177 Due date: 15 Jul, 202515 Jul, 2025 NA
Tender For supply of scintillation detector assemblies for gamma radiation measurement (specifications as per annexure

CTN :39261023 Due date: 27 Jun, 202527 Jun, 2025 NA
Tender For corrigendum : design, support, supply, installation and commissioning, training, warranty and annual maintenance contract of medical cyclotron with turnkey (complete scope as per the attached document in specification) - [equipment -medical cyclotron system] medical cyclotron- bunker type, unshielded with 4 numbers niobium liquid target for 18f production (self shielded), 2 numbers niobium liquid target for 68ga production (unshielded or self shielded), 1 number solid target ( for production of 64cu,89zr, 68ga) (unshielded or self shielded) along with necessary operator and personnel safety interlock system, [equipment -medical cyclotron system] 18f based synthesis modulefully automated cassette-based synthesis module with suitable dual vertical hotcell or equvivalent to handle 20 ci of f18 radioactivity (each working chamber) for routine production of 18f based radiopharmaceuticals., [equipment -medical cyclotron system] synthesis research modulegeneral purpose 18f radiofluorination module with suitable dual vertical or equvivalent hot cell, [equipment -medical cyclotron system] solid target irradiation, processing and synthesis systemsolid target processing system with electroplating+recovery of enriched target+purification) automated module for synthesis of radiopharmaceuticals of zr89,64cu, with suitable hot cell (100 mm lead thickness) [separate prices to be provided for hotcell with camera and hotcell with pb glass window for the working chambers of the hotcells], [equipment -medical cyclotron system] fully automatic dispenser (18f)fully automatic dispenser for vial dispensing with suitable hot cell to handle 20 ci of f18 radioactivity, [equipment -medical cyclotron system] dispenser for solid target-based rpone dispenser for solid target-based radio-pharmaceuticals with suitable hot cell to handle minimum of 5 ci of activity., [equipment -medical cyclotron system] 68ga based synthesis module fully automated synthesis module for radio labelling of 68ga produced from cyclotron with suitable dual vertical hot cell or equvivalent [separate prices to be provided with camera and with pb glass window for the working chambers of the hotcells], [quality control system ] hplchplc with autosampler, [quality control system] gas chromatographygas chromatography with fid and autosampler, [quality control system]tlc scanner, [quality control system] ph reader, [quality control system] mca solid state based mca, [quality control system] dose calibratordose calibrator for qc, lead shielding, [quality control system] bet systemendotoxin test system for quality control, [quality control system]bod incubator, [quality control system] l-bench l-bench for target maintainance, [quality control system] l-bench (qc)l-bench for qc of pet radioharmaceutical, [quality control system]laminar flow benches, [radiation monitoring equipment] central radiation monitoring systemsystem includes software for online data acquisition and backup for six months., [radiation monitoring equipment] gamma area monitor gamma area monitor (0-100mr/h), [radiation monitoring equipment] remote probehigh range gamma monitor with remote probe, [radiation monitoring equipment] stack monitoring systemnai detector for on line stack monitoring systemlead castle for stack monitoring probeintegrated radiation monitoring computer system with complete cabling up to the top floor of building.stack monitoring channel local alarm unitssoftware system for stack monitoringmonitor channel connection kitspare parts kit for stack monitor, stacking monitor channels, area monitors, [radiation monitoring equipment]hand & foot monitor, [radiation monitoring equipment] personal pocket dosimeters (digital), [radiation monitoring equipment] portable gamma dose rateportable gamma dose rate meter + contamination probe, [radiation monitoring equipment] portable survey monitor for neutron, [radiation monitoring equipment] remote probe survey neutron monitor (high range), [radiation monitoring
 Loading, Please wait...

Connect us via What's Up