Get complete information related to latest Fan Coil Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fan Coil Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fan Coil Repair Tenders.
Tender For supply of isolator 3 point 3 kv 400 a complete flp vcb 018 , moving contact for isolator 03 sets for 03 phase flp vcb 019 , fixed contact for isolator 03 sets for 03 phase flp vcb 020 , earth leakage relay flp vcb 024 , diode based rectifier complete flp vcb 029 , epoxy resin moulded 1 phase p t 3 point 3kv 110v 150va flp vcb 034 , pt fuse 3 point 3 kv flp vcb 035 , 72 sq mm ammeter ct operated fpl vcb 036 , 72 sq mm voltmeter 0 5kv ptr 3 point 3 kv 110v fpl vcb 037 , h t hex bolt for main lid and terminal ch size m 10 x 25 fpl vcb 054 , h t hex bolt for terminal chamber cover size m 8 x 20 flp vcb 055 , h t hex bolt for cable box size m 10 x 20 flp vcb 056 , dmc moulded auxiliary terminal flp vcb 046 , h t hex bolt for main lid and isolator lid size m 10 x 30 flp vcb 053 , led lamp holder with lamp flp vcb 043 , limit switch fpl vcb 040 , micro switch for push button element flp vcb 039 , auxiliary contactor 3 no 1 nc 110v coil flp vcb 028 , auxiliary transformer for control circuit flp vcb 023 , coil for shunt trip spring release fpl vcb 017 , shunt trip assembly with coil flp vcb 004 , auxiliary switch for vcb flp vcb 013 , vacuum interrupter 400a flp vcb 006 , epoxy moulded core balance transformer 3 point 3 kv flp vcb 025 , jones plug 18 pins flp vcb 044 , brass gland complete with stud and nut flp vcb 052 , solid state o l and s c r with time delay flp vcb 026 , under voltage relay with time delay fpl vcb 027 , 3 pole magnetic overload relay flp vcb 026a , solenoid operated spring release assembly with coil flp vcb 005 , epoxy cast drive insulator for vi flp vcb 011 , dash pot oil for o l relay 50 ml flp vcb 059 , hrc fuse base 20a for control flp vcb 030
Tender For supply of control,ml fml, sockets,c1b47917083400 , trip coil 110 220v dc, c1b41211176223 , close coil 110 220v dc, c1b41211176223 , spring charging motor, c1b41211176223 , density monitr,alarm cont,c1b41205404008 , density monitr,alarm cont,c1b41205404011 , spares set,lcc,bay types,a8e56200111053 , rupture disc,cb gas chmbr,c1b47911006112 , rupture disc,othr gas chm,c1b47911006012 , discnctr sw,ml fml socket,c1b47915154401 , gas tight barriers, bushings, c1b47901320 , gas perm,barrier, bushing, c1b47901320002 , set of consumables , set of o rings,1bay, c1b9502246000 set , numerical relay trafo. diff. protn. , numerical relay bay ctrl and protn. unit , line diff, protection , 87l relay ckt. dc mcb plus aux contact , molecular filter,sf6,1bay,c1b42702585001 , tc-1 supervision relay , push button for ann accept , indicating lamp for esw q81 close , surge arrestor counter
Tender For corrigendum : supply of electrical spare item for khunti d d - thyristor module psthm 162 19 mcc 200 16 io1 , thyristor module psthm 200 16 mcc 312 18 io1 , tube light 20 w led , flameproof light 60 w led , braided copper wire 6 sq.mm , crocodile clip , flameproof safety torch , ceiling bldc motor fan , rccb 2 pole 30 ma 64 a , earthing cable 10 sq mm copper , copper strip 25 sq mm , sfu unit 63 a 3 pole with neutral , 1 core 1.5 sq mm pvc copper circular sheathed cable with rigid conductor , 1 core 1 sq mm pvc copper circular sheathed cable with rigid conductor , motor operator geared motor device of acb , undervoltage release uvr of acb , shunt trip coil , shunt closing coil , acb front cover sace emax e1n ms 10 , acb front cover sace emax e3n ms 25 , hrc fuse din 400a , hrc fuse base , soft-starter front keypad lcd display assembly with control card , hrc fuse din 250a , hrc fuse din 200a , hrc fuse din 63 a , hrc fuse din 80a , mcb 40a 2pole 240v
Tender For supply of mine line acb vcb tsu gate end box d d - fixed contact breaker 400a 11 06 04b , fixed contact for isolator 200a 05 01 03 , glass fuse with holder bogf , ct for ol lat1005 , current transformer for ol lat3005 , current transformer for ol lat4005 , isolator micro switch assembly 05 05 00 , earth leakage relay 50 750ma with time lag with cbct elm7lat s 80m , glass fuse with holder bogfh , cover bolts 000110a , cover bolts 000110h , indicating lamps lab9acb , overload assembly breaker 30a 100 a 11 01 00a , incoiming gland g1 , shunt trip coils 11 09 03 , push button actuator for el test boes2 , core balance transformer cbt80m , power cable for 400 a for breaker chamber ic and og set iccb4 , fault imposing relay without base booen3r , power cable for 300 a for breaker chamber ic and og set iccb3 , core balance transformer cbt70m , terminal bushing with insulator dmc incoiming 8 mm x 25 mm t5 , no volt coil assly under voltage assly with moulding 11 04 00a , current transformer for ammeter 120 300 5 5 , thermal overload relay 12 00 21 , potential transformer ds1 , on delay timer 135 30 on , aux contactor 220v ac boca2dn1229 , indiciating lamp with pcb mouting lab9 geb , on off rev isolator 300a k4r , resistance 139 geb , current trasfoemr for o l 15va 120 200 5 15 , on off isolator 400 a k4s , on off rev isolator 200a k3r , isolator 3 p on off k3 , vcb shunt trip coil 50 05 00 , potential tranformer 3 point 3kv htptl1 , earth leakage 50 750ma and 750ma 2a dual setting with time lag with cbct elm7dlat s 80m , control relay 110v 135 110 , indicating lamp lab9 tsu ht , vcb closing coil 50 10 00 , neutral monitoring relay with resitance nrmr , bullet pin 3 point 3kv bobp3 , voltmeter 600 for tsu lt 130 v 0 600 sotlt , core balance transformer cbt90m , hrc ht pt fuse boabwna , aux contactor mcra022a7 , vacuum interrupterbevoo53 , ht bushing htta3 point 3 , reset push button contact element no nc boes1 , earth leakage 50 750ma and 750ma 2a dual setting with time lag elm7dlat s , hv bushing httc , multicore bushing mcb9 , current trasformer bo400 5ctr , test off run selector switch bosrp137b , aux. transformer single phase ptfx , auxiliary contactor with coil boca2dn1229 , current transfomer 60 5 15va120 60 5 15 , current transfomer120 100 5 15 , ht bushing with stud 3 point 3 kv htta 3 point 3 , ht hrc pt fusebossabwna , indicator panellab9 3 point 3kv , miniature circuit breaker bosp6 , overload relay magnatic olr3 , resistance 06 05 08 , vacuum contactor 3 point 3 kv bevoo61 3 point 3 , current transfomer coil 110 v dc indigenous bevoo49 , copper terminals with dmc bushingt5 , no actuator boes2 , nc actuatorboes3 , isolator handle h9 , hrc fuse 16 amp 138 16 , hrc fuse 63 amp 138 63 , earth leakage 50 750ma with time lag elm7lat s
Tender For supply of spares for ece make 11 kv 400 amps hop 5 circuit breaker pac bid d d ? g? g - power pack unit part no bd5115999 , e l rely w dgtl dsply facility part no ea5116610c , idmt rely set w 2 oc and 1 e fault set part no ea5116561 , isolating spout assly with nylon shroud part no bc5119977 , auxiliary plug and socket assembly set part no bd5114850 , instrument chamber box w intrnl wrng part no bdw5117771 , jaw contact assembly set part no bd5114050 , ct 11kv 15va 5p10 equal to 1 ctr 200 by 100 by 5 by 5a epox part no ba5111134 , 11kv 400a 250mva troly w atchmnt part no bd5118268 , pt 3p 50hz 150va cls1 w ht fus 11kv 110v part no bd5114103 , right angle cabl end box w suprt plate part no bd5117225 , high speed tripping relay part no ea5116890 , under and over voltage relay part no ea5116591 , operating mechanism complete set part no bd5114911 , partition plate assembly part no bd5115255 , shunt trip coil assly part no 5111650ts , ocb raising and lowering handle part no bd5114718 , pt connector set part no bd5117788 , elr core balance current transformer part no ea5116650 , assorted hardware part no bd5119295 , cable entery box part no bd5112290 , epoxy ocb bushing 3 by 4 inch 400 630a w mc plug part no pd5118195 , rotary switch w link and fixing plate part no bd5119191 , voltmeter 11 kv 110v digital part no dgv51111000 , ampere meter 60 by 5a part no dgm51160 , ampere meter 300 by 150 by 5 a part no dgm511300
Tender For supply of spares for electroteknica make flp 3 point 3 kv vcb pannel d d ? g? g - shunt trip coil assembly 110v dc part no nvcbv0001 , electrical release coil assly part no v0022 , aux switch assy part no v0024 , flex connector part no v0028 , secondary plug and socket part no v0032 , fiber glass cover part no v0037 , fibre glass barrier set for fixed type v part no v0039 , drive insulator for vcb part no v0041 , push to trip assly part no v0042 , spring charge indicator paart no v0043 , operating mechanism part no om009 , spring for operating mechanism part no om0010 , castle lock with key part no fsv00118 , vaccum interrupter part no v0048 , vacuum circuit breaker assly vcb9576 part no vfs0062 , indicating lamp part no p0043 , trip neutal close switch part no p0045 , ammeter voltmeter selection switch part no p0046 , earth leakage relay test reset switch part no p0047 , rectifier capacitor unit part no p0048 , resin cast core balance transformer part no p0051 , resin class ct class isp10 by ci10 part no p0056 , under voltage release part no p0057 , auxiliary contactor 110 vac part no p0061 , control fuse 2 to 10a part no fsv00116 , fuse base and carrier part no fsv00117 , fiber glass barrier set part no i0036 , 4 hole support insulator part no i0039 , oil dash pot over load release part no p0058 , breaker terminal top part no v0029 , breaker charging handle part no v0030 , push button switch part no p0044 , kwh meter part no fsv00107 , ht hrc fuse for p t part no fsv00110 , earth leakage relay part no p0049
Tender For corrigendum : supply of different materials used for testing at electricity test division, unnao under electricity distribution circle, unnao. - o/c & earth fault relay (ashida adr 241 b), clamp meter (0-20a), combination pilier (taparia), rachet set (taparia), grinder bosch (240 volt, ac operated), drill machine (240 volt, ac operated), spanner set (taparia), pcv tape (red, yellow & blue) colour, pin type & u type copper lug 2.5 mm2 (100 each), dc indication led (24 volt to 36 volt) suitable for 11kv & 33kv control pannel, flexible copper wire havells (red, yellow & blue, black color) 2.5mm2, tripping coil with assembely make tripping coil assembly stable 33 kv vcb (stelmec, toshiba, cg, schneider), oti(oil temperature indicator) with limit switch alarm & trip contact, temp range (0 c to 150 c), wti (winding temperature indicator) with limit switch alarm & trip contact, temp range (0 c to 150 c) with gradient adjustment through a shunt for ct secondary input (1amp to 5amp), closing coil with assembely make tripping coil assembly stable 33 kv vcb (stelmec, toshiba, cg, schneider)