Get complete information related to latest Fan Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fan Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fan Repair Tenders.
Tender For tender for installation of 02 no. new bhel-make, 6.6kv, 1300kw, id fan motor (with base plate) by replacement of old existing id fan motor (with base plate) on the exiting foundation at ph-i, htps, kwb
Tender For corrigendum : supply of miscellaneous control and instrumentation items for btps, obra. - lubricator air filter with pressure gauge max. inlet pr. 15kg/cm2 outlet pr. range: 0-10kg/cm2 connection: 3/4" npt, manual drain 40micron sintered bronze/ metal bowl filter element, lubricator air filter with pressure gauge max. inlet pr. 15kg/cm2 outlet pr. range: 0-10kg/cm2 connection: 3/4" npt, manual drain 40micron sintered bronze filter element, stub for steam line and w.o. outlet bfp (as per sample), thermowell for steam / water line and w.o. (as per sample), thermocouple k-type duplex with head l-400mm od-19mm, k- type thermocouple od-6mm l-320mm bsp (m), k- type without head connation thermocouple for boiler/ turbine metal temperature measurement l-15mtr, od-6mm, rtd (prt-100*ohm*) thermocouple type along with thermowell head connection 320mm, od-6mm duplex bsp, rtd (prt-100*ohm*) capsule type thermocouple along with thermowell head connection l-20mm, od-4mm, (20x10) & od-3mm (5 nos) duplex type m&f adjust, k- type thermocouple od-6mm l-400mm bsp (m), pa fan temp. switches 0-120 deg. c1. dial size: 150 mm normal dia, white back ground, black marking2. range: 0 120 c3. case: weather proof to ip: 65 as per is:13947, die cast aluminium, bezel ring4. stem: 10 mm dia in ss 316, total stem length-200 mm5. connection: 3/4" npt(m) gland table in ss3046. capillary: ss 304 covered, 10 meter long solid drawn7. accuracy: 1% of fsd for indication & 2% of fsd for switching8. over range: 120 % of fsd9. window: acrylic10. contacts: 2spst contact, both normal op to close on rise of temperature rated 30 va, 240 v ac., temperature switch: fd fan stem length 175mm, 0 120 deg. c with sleeve zero adjustment at outside the casing along with fitting.tech. specification: -1. dial size 100 mm nominal dia, white back ground, black marking.2. range 0 120 deg.c.3. case weather proof p: 65 as per is: 2147, die cast aluminium with screwed aluminium, bezel ring.4. stem 10 mm dia in ss 316, total stem length-175 mm.5. connection 1/2" npt (m) gland adjustable in ss304.6. capillary ss 304 covered + pvc coating, 03 meter long.7. accuracy of fsd for indication 2% of fsd for switching.8. over range 120 % of fsd.9. window acrylic.10.contacts 1spst contact, both normal open to close on rise of temperature rated 30 va, 240 v ac., temperature switch stem size 300mm for id fan temperature switch: stem length 300 mm, 0 120 deg. c with sleeve zero adjustment at outside the casing along with fitting.other tech. specification: -1. dial size 100 mm normal dia, white back ground, black mar 2. range 0 120 deg. c.3. case weather proof to ip: 65 as per is: 2147, die cast aluminium with screwed, bezel ring.4. stem 10 mm dia in ss 316, total stem length-300 mm.5. connection 1/2" npt (m) gland adjustable in ss304.6. capillary ss 304 covered with coating, 03 meter long.7. accuracy 1% of fsd for indication 2% of fsd for switching.8. over range 120 % of fsd.9. window acrylic.10. contacts 1 spst contact, both normal open to close on rise of temperature rated 30 va, 240 v ac, temperature switch stem size 150mm temperature switch: stem length 150 mm, 0 200 deg. c with sleeve zero adjustment at outside the casing along with fitting.other tech. specification:1. dial size 150 mm normal dia, white back ground, black marking2. rang 200 deg. c3. case weatherproof to ip: 65 as per is:2147, die cast aluminium with screwed, bezel ring4. stem 10 mm dia in ss 316, total stem length-150 mm5. connection 1/2" npt(m) gland adjustable in ss3046. capillary ss 304 covered with pvc coating, 03 met ng7. accuracy 1% of fsd for indication 2% of fsd for switching8. over range 120 % of fsd9. window acrylic10. contacts 1spst contact, both normal open to close on rise of temperature rated 30 va, 240 v ac, digital ind 4 digit dual channel 138x32mm, digital ind 4 digit single channel 138x32mm, 3 nos.)
Tender For corrigendum : supply of hydraulic connectors e e--pa fd had connector , id fan had connector , fan hub connector type 1b , fan hub connector type 1 a , fan hub connector type 2 b , fan hub connector type 2 a , pressure gauge connector type 1 , pressure gauge connector type 2 , pressure gauge connector type 3 , jack connector , ferrule connector for pipe od 15mm , ferrule for 18 mm od pipe
Tender For corrigendum : maintenance of electrical installation & fans, repair and maintenance of p/sets, lifts, dg set, ff equipments, fa system etc at imu mumbai port campus, sewri, mumbai. sh: complete comprehensive maintenance of 3 nos. johnson elecvators.subwork/packages:complete comprehensive maintenance of 3 nos. johnson elevators.
Tender For corrigendum : maintenance of electrical installation and fans, repair and maintenance of dg set, pump set etc at cgo complex, poonkulam, trivandrum. sh. shifting the location of nvr of cctv system along with rack, providing additional display with control pc.subwork/packages:single
Tender For maintenance of electrical installation and fans, repair maintenance of dg dets,water supply pump sets, substation, street lights, ac units and lifts etc at esi super speciality hospital at ashramam, kollam. sh: replacement of 25 tr compressor of voltas make air cooled scroll consdensing unit.