Tender For replacement of damaged 150/200mm dia sewer line with 300mm dia swg line near huda ph-ii (dumping yard) under chandanagar section, sub division ii, operation and maintenance division xvii hmwssb (reservation earmarked for waddera/sagara, as per g.o.ms. no: 59, dtd: 21.05.2018).
Tender For replacement of existing damaged 200/300mm dia swg sewer line at maqtha to avoid frequent pollution under miyapur section, sub division ii, operation and maintenance division xvii (reservation earmarked for schedule castes, as per g.o.ms. no: 59, dtd: 21.05.2018).
Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim
Tender For supply, installation, testing and commissioning of chlorine dosing pump with all allied accessories of various booster pumping station in cr park ward under greater kailash constituency ac_50. - dosing pump of capacity 9.5 lph, 7 kg pressure/cm2, pp head along with pvc fitting syphone valve, foot valve & ldpe tubing. make: milton roy/clomexdjb approved, installation, testing & commissioning of dosing pump sets with proper wall supporting arrangement to hold the pump set, the work includes providing all pipes and special to supply sodium hypo chlorite solution properly to main delivery line by making holes with utmost care and make the systems leak proof and testing on full load during running of pump as per site requirement & direction of engineer in charge., fixing of ms socket of required size by drilling / threading / welding and making it leak proof fixing suitable nozzle for injecting chlorine solution at the time of operation of bps as per site requirement & direction of engineer in charge., providing of 500 ltr pvc dosing media container.(chlorine resistant)
Tender For corrigendum : shifting of 610 mm dia. ms pipe line from nagalpar hws to adipur hsr due to anjar nagalpar bypass road work under deposit work (part ii).
Tender For supply of fabrication and erection of conical portion at ash collecting tower,fabrication of tail pipe installed at ash collecting tower,barricading work by ms plate at eco hopper at unit 11 and strengthening work of eco platform in unit 9 and 10.,interconnection of vacuum line of unit 11 to unit 10,strengthening of seal box of 9b by channel and beam support at ash collecting tower unit 9.,erection of 6 inch or 8 inch m.s. pipe from awrs intermediate sump pit to ash dam
Tender For supply erection of new turbo blowers by replacing old blowers with accessories repairing and replacing air ms pipe line and miscellaneous work at 18 mld gangapurgaon stp, nmc , nashik