Tender For supply of ff8301700823 coupling pin bush part no 142 , ff8301700831 impeller part no 02 , ff8301700858 top shaft part no 84 , ff8301700866 line shaft bottom part no 20a , ff8301700874 line shaft part no 20 , ff8301700882 line shaft coupling part no 82 , ff8301700890 spider bush model svt 275 33a , ff8301700904 split ring set part no 78 , ff8301700912 rubber bush teper pipe part no 77a , ff8301700920 rubber bush diffuser part no 77 , ff8301700947 guard ring part no 75 , ff8301700955 internal circlip part no 51 , ff8301700963 taper pipe bush part no 21b , ff8301700971 bronze bush for diffuser part no 21a , ff8301700980 suction bush part no 21 , ff8301700998 wear ring part no 16 , ff8132040465 bearing housing with internals part no 33 and 86 m , ff8301701048 centre ring part no 16a , ff8301701056 casing wearing ring part no 16 , ff8301701064 sleeve nut nde part no 13a , ff8301701099 split gland part no 8 , ff8301701102 lantern ring part no 7 , ff8301701110 sleeve part no 6 , ff8301700840 pump shaft part no 10 , ff8301701021 horizontal pump impeller part no 02a , ff8301701030 horizontal pump impeller part no 2 , ff8301701080 shaft part no 10
Tender For procurement of consumable spares for burners - linear clamp, pipe -1 inch sch 40x3.00 lg t.o.e, two inch std sch. 40 pipe l 110mm, two inch class 150 malleable iron, silicone hose with straight ends length, nippel-taper pipe threads sch-40 2.000x4.500 lg - long, fittings-threaded pipe-class 300 45 deg. elbow, 2.0inch-11.5, nippels - sch 40 pipe-long nippel .50-14x1.50 inch lg, coupling - reducing threaded 1.000x.500 - class 150, clamp,linear w/pltd hex scr, one inch class 150 malleabel iron threaded union, hose , 1 1/2 inch i.d,. ytpe2fs, spring seal for horizontal adjusting mechanism (windbox), spring seal for dampers, e circlip for link, split collar, shaft seal
Tender For supply and installation of necessary equipment for updating the fire and safety system installed in regional office, chandigarh - diesel engine driven main fire pump supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (diesel driven pump) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads.(for 1620 lpm at 56 m head) note- the head of the pump is selected in a manner so as to give a minimum 3.5 kgf/cm2 pressure at the highest farthest point., control panelfabrication, supply, installation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :incoming250a, 50ka 4 pole mccb, ics=100% icu rating ,digital voltmeter 0-500v with selector switch digital ammeter (0-250 a) with selector switch & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps, set of copper bus bar 300a.outgoing( note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump125 a, 50ka tpn mccb, ics=100% icu, with fully automatic star/delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.jockey pump63 a, 50ka tpn mccb, ics=100% icu, with suitable hp fully automatic star/delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.diesel engine controlcontrol for diesel engine comprising -automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low lub. oil pressure, high water temp and engine on indication, battery charger suitable for 12v/24 v dc with boost and trickle selector switch, 0-30 v dc volt meter, and 0- 20 a dc ammeter. all standard relays and accessories for automatic operation of diesel enginesystem controllerdesigning, supply, installation, testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, pressurization pump, terrace pump in sequence as per specification consisting of relays, timers. sensors, annunciat