Tender For construction of new kitchen for opal mess at nit, trichy. sh: building portion including water supply, sanitary installation, aluminium work, water proofing, including internal electrical installations, lightning conductors, external service (mv panel & ug cabling), emergency light & illuminated signages, solar water heater, ro plant, water coolers, firefighting with down comer system, manual firealarm system, kitchen ventilation system and external lighting additional works for opal mess kitchen. sh: providing and fixing of wall tiles, floor tiles & other miscellaneous works in the existing new kitchen for opal mess.
Tender For supply of loop card for firealarmcontrolpanel , monitor module addressable type monitor module. , control relay module addressable control relay module. , optical cum thermal detector intelligent addressable multi criteria optical cum thermal detector wit , optical cum chemical detector intelligent addressable type, maintenance easy optical cum chemical de , response indicator , break glass type manual call point intelligent addressable break glass type manual call point. , sounder or hooter addressable type loop powered /external powered sounder or hooter with multiple to
Tender For supply of lab equipments - purchase of lab equipments, acidity test kitspecifications:ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, single phase resistive loadspecifications:type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability, three phase resistive load specifications:rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided, three phase capacitor bank specifications: 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided, 3 phase auto transformer starter specifications: 3-phase variable autotransformer input: 415 v output: 0 470 v ac (continuous) current: 15 a copper wound, carbon brush type heavy duty toroidal/core construction mounted in powder coated ms/crca enclosure front panel mounted voltage control knob with scale indication proper insulated terminals provided floor/bench mounted type suitable for laboratory use input / output terminal arrangement provided mcb/fuse protection provided proper earthing terminal provided ventilation arrangement for heat dissipation, 3 floor lift interfacing model specifications: type: table-top lift model floors: 3 levels structure: transparent acrylic / ms frame cabin: moving lift car with guide rails drive: dc geared motor / stepper motor motion: up/down movement, floor indication leds (1, 2, 3) direction indicators (up/down), start & stop atevery stage, over load limit control three-floor lift operation plc interfacing and programming floor selection logic automatic stopping at floors direction indication system educational demonstration of elevator automation, mcb elcb trainer kit specifications: 1 phase/3 phase, 2/3/4 pole, 3a-16a single pole mcb 2-5amps two pole elcb 30ma lamp load single phase 5amps panel enclosure and terminal outlets, signal generator specifications: frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vp-p. rise time: 100 ns. distortion, dso specifications: bandwidth: 50 - 100 mhz. sampling rate: 1gs/s. channels: 2 (minimum) power supply: 100v 240v ac, 50-60 hz automatic measurement: vpp, vavg,rms, frequency, period, vmax, vmin, rise time, fall time, + width, - width, +duty, - duty etc., horizontal scale: 5 ns/div 50 s/div or equivalent vertical resolution: 8 bits (2 channels simultaneously) vertical sensitivity: 1 mv/div 10 v/div (at input) waveform math: +, -, x , , invert, fft etc., waveform storage: 16 waveforms or equivalent communication interface: usb host, usb interface. 7-inch color display or equivalent input impedance - 1 m 2%, // 20 pf 2 passive probes (1x/10x), pwm based
Tender For purchase of equipments for eee department - 3 phase capacitor bank :* 3-phase capacitor bank * rating: 2 kvar * voltage: 440 v ac * frequency: 50 hz * heavy duty self-healing capacitor units * powder coated ms enclosure * compact panel mounted/floor mounted construction * proper ventilation arrangement to be provided * capacitor duty contactor/switch to be provided * fuse/mcb protection to be provided * discharge resistors to be provided for safety * proper earthing arrangement provided, 3 phase auto transformer starter :* 3-phase variable autotransformer * input: 415 v * output: 0 470 v ac (continuous) * current: 15 a * copper wound, carbon brush type * heavy duty toroidal/core construction * mounted in powder coated ms/crca enclosure * front panel mounted voltage control knob with scale indication * proper insulated terminals provided * floor/bench mounted type suitable for laboratory use * input/output terminal arrangement provided * mcb/fuse protection provided * proper earthing terminal provided * ventilation arrangement for heat dissipation, linear variable differential transformer measurement trainer :* input supply : 230 v ac, 50 hz * type : linear variable differential transformer (lvdt) trainer kit * lvdt stroke length : 25 mm * lcd display provided * digital voltmeter provided for output measurement * potentiometer provided for calibration and adjustment * signal conditioning circuit inbuilt * zero adjustment and calibration facility provided * test points provided for waveform/signal observation * clearly labeled circuit diagram on front panel * proper insulated terminals and safety sockets provided, plc trainer kit :* plc make :allen-bradley / delta electronics / siemens or equivalent* digital inputs : 8 20 nos.* digital outputs : 6 12 nos. (led / relay type indication)* communication port : rs232 / usb / ethernet (if available)* programming method : ladder logic programming* toggle switches for digital input simulation* led indicators for output status indication* analog potentiometers for analog input experiments* proximity sensor interface provided* relay output interface provided* input supply : 230 v ac, 50 hz* built-in regulated 24 v dc power supply* ladder diagram programming software to be provided* compatible programming software license to be provided* suitable for basic plc programming and automation experiments, conveyor arrangement with siren :* input supply : 12 v dc / 24 v dc / 230 v ac, 50 hz* control mode : manual / automatic operation using plc* conveyor arrangement with geared dc motor provided* proximity sensor provided for object detection* start and stop push buttons provided* audio siren indication provided* plc based control and sequencing operation provided* mini conveyor setup suitable for laboratory demonstration* geared dc motor driven conveyor mechanism* smooth belt movement with roller arrangement, digital storage oscilloscope (dso) :* bandwidth: 50 - 100 mhz. * sampling rate: 1gs/s. * channels: 2 (minimum) * power supply: 100v 240v ac, 50-60 hz * automatic measurement: vpp, vavg,rms, frequency, period, vmax, vmin, rise time, fall time, + width, - width, +duty, - duty etc., * horizontal scale: 5 ns/div 50 s/div or equivalent * vertical resolution: 8 bits (2 channels simultaneously) vertical sensitivity: 1 mv/div 10 v/div (at input) * waveform math: +, -, x , , invert, fft etc., * waveform storage: 16 waveforms or equivalent communication interface: usb host, usb interface. * 7-inch color display or equivalent * input impedance - 1 m 2%, // 20 pf 2 passive probes (1x/10x), on/off control of lamp using solid state relay kit:* type : solid state relay (ssr) trainer kit* control/input voltage : 12 v / 24 v dc or up to 30 v dc* output load voltage : 230 v ac, single phase* load control : on/off control of ac lamp load* solid state relay based switching circuit* opto-isolated input control* built-in ac lamp load* manual on/off switching arrangement* led indication for input and output statu
Tender For purchase of equipments for ece department - function generator frequency range: 0.1 hz to 5 mhz display: 4 to 6 digit led display output waveforms: sine, triangle, square, pulse, ramp . amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v, strain gauge trainer kit ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual., temperature measurement kit sensors: rtd (pt-100), thermocouple (fe-k/j-type), and/or thermistor (ntc). display: 3 digit led/lcd digital display (typically 200 mv fsd). temperature source: portable water kettle or heater block. signal conditioning: on-board circuitry for amplification, linearization, and cold junction compensation. test points: multiple 2 mm / 4 mm banana sockets for monitoring input/output signals. power supply: 230 v ac, 50 hz, single-phase. accessories: glass thermometer, 10 k ntc thermistor probe, k-type thermocouple probe, patch cords and user manual., cathode ray oscilloscope bandwidth: dc to 30 mhz (-3 db) - sensitivity: 1 mv/div to 5 v/div - display modes: ch1, ch2, dual (chop/alt), add, sub - timebase: 0.2 s/div to 0.5 s/div (essential for slow bio-signals) - magnification: x 10 sweep magnifier - triggering: alt triggering, auto, norm, - tv-v/h with source selection (ch1, ch2, line, ext). - input impedance: 1 mohm || 25pf - included accessories: two 60 mhz passive probes, power cord, and user manual
Tender For tender for supply of supplying , installing , testing and commissioning approved make microprocessor based single (01) loop , networkable addressable firealarmcontrolpanel , supplying , installing , testing and commissioning approved make digital audio amplifier. , supplying , installing , testing and commissioning approved make remote paging station for zone selection , supplying , installing , testing and commissioning approved make modbus interface gateway , the mimic annunciator for the firealarmcontrolpanels (facp). , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector , supplying , installing , testing and commissioning approved make addressable manual call point , supplying , installing , testing and commissioning approved make addressable control module for sounders , supplying , installing , testing and commissioning approved make addressable relay module for ahu , access control , lifts , staircase pressurization , fire suppression & other third party outputs , supplying , installing , testing and commissioning approved make isolator module for isolating short / dewired / loose circuits with automatic resetting arrangement , supplying , installing , testing and commissioning approved make response indicator , supplying , installing , testing and commissioning of hooter cum strobe with in-built lithiumion battery , supplying , installing , testing and commissioning approved make 2w multi-tap wall mount speakers , supplying , installing , testing and commissioning of approved make auto dialer which supports gsm and pstn both , supply and laying of 2 c x 1.5 sq.mm. armoured cu multi-stranded twisted shielded frls copper cable , red in colour. , camc for 4 years after expiry of one year warranty of addressable fire detection system
Tender For supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset controlpanel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission