Web Analytics Made Easy - StatCounter

Fire Alarm Control Panel Tenders

Get complete information related to latest Fire Alarm Control Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fire Alarm Control Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fire Alarm Control Panel Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :44846117 Due date: 28 Apr, 202628 Apr, 2026 NA
Tender For supply of isi mark gi pipe all fittings 50 mm dia , lowering laying and jointing gi pipe 50 mm dia , isi mark gi pipe all fittings 80 mm dia , lowering laying and jointing gi pipe 80 mm dia , isi mark gi pipe all fittings 100 mm dia , lowering laying and jointing gi pipe 100 mm dia , isi mark gi pipe all fittings 150 mm dia , lowering laying and jointing gi pipe 150 mm dia , isi mark gi pipe all fittings 200 mm dia , two coats of enamel paint over and one coats of red oxide primer , hydrant valve type a , short branch pipe , hose reels drum , hose boxes single door , rrl hose pipe , 4 way fire brigade inlet , wrapping 4mm thick protection coating 150mm , wrapping 4mm thick protection coating 100mm , ms steel for supports , core cutting 150 mm , core cutting 100 mm , excavation for pipe line , rcc pipe 300 mm dia , lowering laying and jointing rcc pipe 300 mm dia , refilling of trench , diesel driven pump , electric driven main fire pump , jockey pump , fire pump control panel , pressure vessel , sluise valve 200 mm dia , sluise valve 150 mm dia , sluise valve 80 mm dia , sitc butterfly valve ci body 150 mm dia , sitc butterfly valve ci body 100 mm dia , double flanged metal bellows 150 mm dia , double flanged metal bellows 80 mm dia , y type stainer or foot valve 150 mm dia , y type stainer or foot valve 80 mm dia , sitc nrv non return valve 150 mm dia , sitc nrv non return valve 80 mm dia , air release valve , cable end termination and connection 1 point 5 sqmm , cable end termination and connection 4 sqmm , cable end termination and connection 16 sqmm , cable tray system , pressure gauge , pressure switches , ms steel for supports , addressable 2 loop main panel , fire alarm control panel , single loop card , photoelectric smoke detector , manual call point , addressable sounder , computer based software , isolator base , 1 point 5 sqmm 2 core red cable armd , 12v 7ah batteries for panel , abc powder type fire extinguisher 6kg , co2 type fire extinguisher 4 point 5 kg , emergency exit board , fire hydrant board , fire alarm call point board , abc extinguisher board , co2 extinguisher board , pass or race board , assembly point board , left side man running with arrow tape board , anti skid tape , evacuation plan , fire buckets , emergency light with exit sign , maintenance of equipment 1st year , maintenance of equipment 2nd year , maintenance of equipment 3rd year , legal and liasoning charges , rcc water tank 100000 ltr , rcc frame structure for pump , cc grade m25 , mass cement concrete in 148 proportion , tmt fe500 steel , pvc pipe 63 mm dia , pvc pipe 75 mm dia , lowering laying and jointing pvc pipe 63 mm dia , lowering laying and jointing pvc pipe 75 mm dia

State Government

CTN :44798192 Due date: 28 Apr, 202628 Apr, 2026 1.97 Lacs
Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high water temperature gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in control panel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the diesel engine, alternator and amf panel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amf control panel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge

Central Government And Public Sector

CTN :44765998 Due date: 27 Apr, 202627 Apr, 2026 NA
Tender For tender for supply of fire alarm : -morleyias-make multi-protocol fire alarm control panel(model -zx5e) , zx5e panel loop driver card for morleyias protocol , morleyias-make optical fire detector (model no. - mi-pse-s2-iv) , zx5e panel loop driver card for apollo protocol , lcd display card of zx5e fire alarm control panel

Central Government And Public Sector

CTN :44728895 Due date: 14 Apr, 202614 Apr, 2026 41.42 Lacs
Tender For supply installation and commissioning of optical fiber cable and network infrastructure for interconnection of fire alarm control panels

Central Government And Public Sector

CTN :44687578 Due date: 18 Apr, 202618 Apr, 2026 NA
Tender For supply of supply, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarm control panel with 2 loops modules , supply, installation, testing and commissioning of intelligent addressable multi criteria detector with a combination of optical and thermal including mounting base , supply, installation, testing and commissioning of intelligent addressable smoke detector including mounting base with led , supply, installation, testing and commissioning of addressable weather proof outdoor manual call point with ip rating of ip 67 , supply, installation, testing and commissioning of addressable loop powered stand alone sounder outdoor with inbuilt isolators , supply, installation, testing and commissioning of active repeater panel to be connected peer to peer with main fire alarm panel
 Loading, Please wait...

Connect us via What's Up