Tender For supply of intrinsically safe conventional smoke detector chamber to n & s solutions part no. soc-e-is chamber suitable for fire/smoke detection with alarmsystem train-18 vande baharat coaches fitted with n & s solution make as per rdso spec.no.rdso/2008/cg-04/rev-06. [ warranty period: 30 months after the date of delivery ]
Tender For bid to ras supply of refurbishment of room flooding system of server room at sauw ins satavahana c c -refilling of hfc 227ea gas 1,1,1,2,3,3,3 hepta fluro propane, zero odp, stored pressure, gas , conventional gas release panel with battery backup and cross zoning facility 2-zone with fire ext automatic mini intuitive fk-5-1-2 300gm ss sp red 79 c with nrv , ms container strap for mounting and fixing the agent containers to the wall , ul container strap for mounting and fixing the agent container to the wall , valve assembly and arrangement for supervisory switch connection for monitoring cylinder pressure, a pressure gauge with a safety burst disc and a safety cap 25 bar , pressure gauge cum switch for monitoring the cylinder pressure 0-60 bar, 22. 50 bar switch point pressure switch wasco switch point 5bar 72. 5 psig imp with fire ext automatic wm fk 5-1-12 4kg , hydro static pressure test 50 bar, inverted baker test, helium leak detection test, epoxy powder painting, dismantling, commissioning charges , conventional optical smoke detector with double dust trap chamber design, optimized performance using internal algorithm, central led for 360 status visibility, compiles to en 54-7 standard , conventional rate of rise heat detector, heat alarm threshold temperature 58 c central led for 360 status visibility, complies to en 54-7 standard and approved by lpcb, vds , installation and delivery charges
Tender For e-tender annual maintenance contract for maintenance of fire protection fire/ smoke/heat detector system available at 400kv/220kv koradi-1 substation under 400kv rs (o&m) division koradi
Tender For following works shall be carried out quarterly during the contract period for the two identical sets of co2 flooding system at mghe power house. the one set of system for carting to the units-1,2,3&4 and the second set of system for carting to units-5,6,7&8. i)cleaning of heat detector externaly with dry cloth ii)ensure working condition of heat detectors iii)cleaning of smoke detector externaly with dry cloth iv)ensure working condition of smoke detectors v)simulate heat and smoke detector simultaneously and check for cross zone vi)checking for leakage in pilot cylinder vii)checking the weight of co2 pilot cylindersviii)check the condition of co2 pilot hose ix)check the condition of co2 discharge hose x)inspect pressure switch and check for its functioning xi)inspect maual call points and check for its functioning xii)inspect abort switch and check for its functioning xiii)inspection of online weigh monitor and check for its functioning xiv)inspect hooter with strobe and check for its functioning xv)checking for healthiness of the battery xvi)checking the condition for slave nrv xviichecking the condition for master nrv xviii)checking of solenoids. xix)refilling of co2 cylinder and pressure testing 45 kg capacity and 4.5kg capacity (in case release of co2 gas during generator fire incidents) xx)any other work connected with the system not explicitly mentioned shall also be carried out for safe and proper operation of the system. xxi)conducting the demo of operation of the co2 flooding system twice (once in 2 quarter) during the annual maintenance contract period for kpcl staff.
Tender For corrigendum : supply of supply of intelligent multi-criteria photo electric smoke & thermal detector, white colour, suitable , supply of 2-zone gas release firealarm panel designed for gas suppression systems. it features a 16 , supply of addressable dual- action manual pull station-red in colour, designed for firealarmsystems , supply of sounder with 90 db output at 1 metre distance cum strobe lights with 110 cd as per specifi , supply of dual-action manual abort station - yellow in colour, designed for firealarmsystems. cons , supply of dual-action manual release station -green in colour, designed for firealarmsystems. cons , supply of addressable relay output module with programmable dry contact output for interfacing with , supply of addressable supervised control module for operating sounders/ horns with line monitoring, , supply of addressable monitor module for supervision of potential free contacts such as flow switche , supply of 2c x 1.5 sq. mm fire survival un- armoured cables (300/500 v) with copper conductor, cross- , supply of electric gas release caution sign boards (24 v dc) for approved locations. make: std , system rectification, modification, re-programming & cleaning charges
Tender For corrigendum : supply of firedetectionalarmsystem spares d d - telescopic 4 section access pole , fire smoke and heat detector removal tool of adjustable diameter , firedetection aerosol dispenser suitable for testing detectors , non flammable, hfc free smoke aerosol smoke detector tester , glass elements for replacing broken glasses in manual call point
Tender For supply of firealarm and detectionsystem e e - 2 loop addressable fire panel , addressable photo electric smoke sensor with base , addressable manual call point , addressable hooter cum strobe , input module , addressable heat detector
Tender For nsac and substation fss - 1. firealarm control panel conventional, conventional, 2-zone supply, installation, testing <(>&<)> commissioning complete with visual indications for alarm, fault, short/ open circuit, zone mimic board etc. 2-zone sector panel / conventional panel as per is standards (make and model: ravel) conventional, 2-zone supply, installation, testing <(>&<)> commissioning complete with visual indications for alarm, fault, short/ open circuit, zone mimic board etc. 2-zone sector panel / conventional panel as per is standards (make and model: ravel) 2. supply & fixing of optical smoke with mounting base, led (make and model: (apollo, siemens, honeywell, simplex, notifier) detector base mounting base for smoke detector (make and model: ravel) detector (photoelectric type) complete with base, led indication, suitable for ceiling mounting, conforming to is 2189 - (make and model: ravel) 3. supply & fixing of manual call point (make and model: ravel) (mcp), break glass type / resettable type, complete with mounting box, suitable for firealarmsystem, conforming to is 2189- (make and model: ravel) 4. supply & fixing of hooter cum strobe, (make and model: ravel) electronic hooter with flashing strobe light, suitable for indoor use, conforming to is 2189 - (make and model: ravel) 5. supply & laying armoured cable 21.5 sqmm (frls/swa) 21.5 sqmm (frls/swa) - make reputed 6. supply, installation, testing & electrical, interconnection, loop termination, functional tests commissioning of online 1kva ups with minimum 30 minutes backup for firealarm panel - make apc / vertiv / eaton or equivalent 7. testing, commissioning, as-built drawings, test certificates, o<(>&<)>m manuals documentation <(>&<)> drawings as-built drawings, test certificates, o<(>&<)>m manuals