Tender For tender for supply of resistance temperature transmitter and indicator - resistance temperature transmitter ( resistance to current converter) , make -elektra precision .input- rtd pt-200. temperature range 0-100 degree centigrade , output- 04 to 20 ma dc (two no of output) zero & span adjustable. power supply- 118 vac with connector. other detail as annexure-1.(bidder should comply one to one in specification as attached) , spare elektra ( earlier lektrolab ) make resistance temperature transmitter. input rtd pt.200. temp range- 230 - 320 degree centigrade. o/p- 04 to 20 ma dc. single output. other common details as per attached annexure-1. , spare elektra ( earlier lektrolab ) make resistance temperature transmitter. input rtd-pt.200. temp range- 0-320 degree centigrade. output- 04 to 20 ma dc with double isolated outputs. other common details as per attached annexure-1. , resistance temperature transmitter ( resistance to current converter) , make-elektra precision .input- rtd pt-100. temperature range 0-100 degree centigrade , output- 04 to 20 ma dc (two no of output) zero & span adjustable. power supply- 118 vac with connector. other detail as annexure-2.(bidder should comply one to one in specification as attached) , indicating alarm meter , make - m/s elektra precision systems , tag-flow indicating alarm meter , range-0-400 ft/sec , alarm -high , alarm relay-one for high alarm , input -4-20ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag-temperature indicating alarm meter , range-0-100 degree c , alarm -high , alarm relay-one for high alarm , input -4-20ma , mounting arrangement-1a , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- differential pressure indicating alarm , range- -15 to +25 gm/cm2 , alarm -high , alarm relay-one for high alarm , input -4-20ma , mounting arrangement-1a , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating alarm , range- 0-700 (squre root scale flow) lpm , alarm -low , alarm relay-one for low alarm , input -10-50ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- temperature indicating alarm , range- 0 to 70 degree c , alarm -low/high , alarm relay-one for high alarm and one for low alarm , input -4-20ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating meter , range- 0-6 (squre root scale) klpm , alarm -no alarm , alarm relay-no alarm , input -10-50 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- level indicating meter , range- 0-10 meter , alarm -no alarm , alarm relay-no alarm , input -4-20 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating meter , range- 0-10.7 meter / sec & 0-30 feet /sec , alarm -high , alarm relay-one for high alarm , input -4-20 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating meter , range- 0-10.7 meter / sec & 0-30 feet /sec , alarm -high , alarm relay-one for high alarm , input -0-4 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- pressure indicating alarm meter , range- 0-0.7 kg/cm2 , alarm -high/low , alarm relay-one for high alarm & one for low alarm , input -4-20 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alar