Tender For non-comprehensive annual maintenance contract for bosch make, intelligent addressable fire detection and alarmsystem in the main building of iacs,jadavpur kolkata
Tender For bid to ras supply of rrc for addressable fire detection system onboard in ships and yard crafts at nsry karwar -repairs to main control panel , repairs to repeater panel , repairs to control cards , repairs to ionization smoke detector , repairs to multi sensors , repairs to temperature heat detection sensor , repairs to flame detector , repairs to manual call point , repairs to front panel switches , repairs to alarm bells lights hooters , repairs to internal circuit wiring , repairs refurbishment of ups , repairs to cabling from main control panel , reprogramming of the pcbs
Tender For maintenance of e&m services at ugc building, new delhi. (sh: augmentation of existing (edward make) addressable firealarm and pa system i/c comprehensive maintenance.)
Tender For maintenance and operation of e&m services in vvip receptorium at afs palam, new delhi-during year 2025-26 sub-head comprehensive maintenance of addressable firealarmsystemsubwork/packages:maintenance and operation of e&m services in vvip receptorium at afs palam, new delhi during year 2025-26 sub-head comprehensive maintenance of addressable firealarmsystem
Tender For tender for supply of sitc and maintenance of addressable firealarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop firealarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. firealarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the firealarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi
Tender For corrigendum : maintenance of electrical installation in non-residential building at chandigarh. (providing annual maintenance contract of addressable firealarmsystem in the divisional library, sector-34, chandigarh).
Tender For supply of firealarm detection system - addressable firealarm panel-02 loops with lcd , addressable smoke detector with base , addressable heat detector with base , addressable manual call point , addressable or conventional hooter cum strobe , addressable control modules , addressable input or output module , addressable input module , response indicator , addressable loop isolator , installation charges
Tender For construction of lecture theatre hall complex (g plus 3) for science faculty building i/c iei and fans, solar compound lighting, service connection, addressable firealarmsystem, down comer system, cctv, vrv/vrf, sub-station & diesel generator set etc. at mcc campus university of allahabad. (sh-providing and fixing exhaust pipe with structure)
Tender For operation and maintenance of 11kv sub station equipment 400 kva diesel generator set internal electrical installations water supply pump sets addressable firealarmsystem vrf ac units lifts fire fighting system cctv lan and epabx ups systems av system and solar plant at epfo office building at begumpet hyderabad for the year 2025 26 sh supply and laying of cat 6 cable for installation of existing cctv cameras including supply, installation, testing and commissioning of others allied accessories as requiredsubwork/packages:supply and laying of cat 6 cable for installation of existing cctv cameras including supply, installation, testing and commissioning of others allied accessories as required
Tender For corrigendum : providing firealarm/ public addressable system at high court extension, block a sector-17, chandigarh. (old district courts complex).