Web Analytics Made Easy - StatCounter

Fire Alarms Tenders

Get complete information related to latest Fire Alarms Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fire Alarms Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fire Alarms Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :39207164 Due date: 13 Mar, 202513 Mar, 2025 8.00 Lacs
Tender For bid to ras providing of custom bid for services - camc for burglary alarm systems

Central Government/Public Sector

CTN :39641467 Due date: 31 Mar, 202531 Mar, 2025 1.93 Lacs
Tender For custom bid for services - yearly routine of fm 200 system-e-065: - yearly routines are falling due on fm-200 system of this unit. |routines to be carried out as per maintenance schedule and system to be proved for satisfactory operation. following jobs to be carried out as part of the routines: () after removal of solenoid valve from fm-200 cylinder head of the system, the following checks need to be carried out: electric remote cabinet opening |from remote and pneumatic release cabinets. () systems check- checks each electrical manual release unit for operation. (ii) check fire alarm and evacuation alarm lights and sounds. (iv) check that all ac are shut down or dampers are closed, if any. (v) check that all pneumatic actuator operates after pre-set time delay. (vii) check operation of discharge pressure switch and check indicator lamp. (viii) reset all pneumatic actuator, electrical actuators, discharge pressure switch and fire alarm system. (ix) pipe work/ nozzle to ensure that they are free from debris. (x) check dust caps are fitted. (xi) containers - check containers are safe mechanical damage, corrosion or unauthorized interference. (xi) check containers brackets are fitted and all bolts tightened. (xii) chek pneumatic actuation tubing is firmly fixed and all connections are |tight..

Central Government/Public Sector

CTN :39649983 Due date: 14 Mar, 202514 Mar, 2025 NA
Tender For contract for new installation, repair and maintenance of fire alarmsystem, burglar alarm system and cctv system (including maintenance of existing fire alarm system, buglar alarm system andcctv system) for the indian bank offices/branches including atm site under nagapattinam zone

CTN :39652699 Due date: 19 Mar, 202519 Mar, 2025 16.68 Lacs
Tender For maintenance of electrical installation and fans including street lights repair and maintenance of substation dg sets lifts ac units afs and wetriser system at gpoa shastri bhawan (main and annexe, additional office accomodation) building chennai 06 sh: initial repair replacement of faculty defective fire alarm and wet riser systems replacement of old fire extinguisher and repair of led sign boards

State Government

CTN :39657580 Due date: 17 Mar, 202517 Mar, 2025 8.25 Lacs
Tender For repairing of fire alarm systems installed in the labs of ab 2 building at iiser bhopal

CTN :39605083 Due date: 15 Mar, 202515 Mar, 2025 6.00 Lacs
Tender For anaerobic culture system-1. capacity: suitable for various volumes, typically ranging from small to large-scale cultures.2.. controlled atmosphere:anaerobic environment: ability to maintain oxygen levelsbelow 0.1% using a combination of gas mixtures (e.g., hydrogen, nitrogen) and catalysts (e.g., palladium).gas monitoring: continuous monitoring and control of gas concentrations (e.g., oxygen, hydrogen) within the chamber.3.temperature range: adjustable temperature control, typically ranging from ambient to 45c or higher.4. temperature uniformity: 0.5c or better throughout the chamber to ensure consistent culture conditions.5.humidity control: adjustable humidity levels to maintain optimal growth conditions for anaerobic organisms.6. chamber material:interior: stainless steel construction for durability, easy cleaning, and resistance to corrosion.exterior: powder-coated steel or equivalent for durability and aesthetics.7. access ports:multiple access ports for introducing samples, adding/removing media, and accessing cultures without disrupting the anaerobic environment.8. monitoring and alarm systems:continuous monitoring of temperature, gas levels, and humidity with alarms for deviations from set parameters.9. sterilization:autoclavable components or built-in sterilization cycle to maintain aseptic conditions.10. safety features:pressure relief valve for controlled release of excess gas.emergency backup power supply to maintain anaerobic conditions during power outages.11. user interface:touchscreen or digital interface for easy operation and monitoring of parameters.programmable settings for different culture protocols.12. data logging:? ability to log and store data related to temperature, gas levels, and other parameters for record-keeping and analysis.13. compliance:ce marked and compliant with international standards such as iso 13485 for medical devices or equivalent standards applicable to laboratory equipment.

corporations/Associations/Others

CTN :39575918 Due date: 26 Mar, 202526 Mar, 2025 69.58 Lacs
Tender For modernisation works including civil, interior works, modular furniture,chairs, electrical installation, fire alarm systems, data, telephone cabling, staircase, toilet renovation in branch office building at vandiperiyar under kottayam division

State Government

CTN :39590049 Due date: 14 Mar, 202514 Mar, 2025 2.31 Lacs
Tender For annual maintenance contract of smoke detection fire alarm systems and burglar alarm system at jog central stores for the period of one year, jogfalls-577435, sagar taluk, shimoga dist, kpcl.

CTN :39357759 Due date: 13 Mar, 202513 Mar, 2025 NA
Tender For corrigendum : providing of supply, installation, testing and commissioning of mgps for oncology cardiology nephro department; service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - lpg cylinder bharat gas 14.5 kg , oxygen jumbo cylinder , copper pipe 12 mm , copper pipe 15 mm , copper pipe 22 mm , copper pipe 28 mm , copper pipe 35 mm , saddle 12 mm , saddle 15 mm , saddle 22 mm , saddle 28 mm , saddle 35 mm , elbow 12 mm , elbow 15 mm , elbow 22 mm , elbow 28 mm , elbow 35 mm , tea 15 mm , tea 22 mm , tea 23 mm , tea 35 mm , coupling 12 mm , coupling 15 mm , coupling 22 mm , coupling 28 mm , coupling 35 mm , reducer elbow 12-15 , reducer elbow 12-22 , reducer elbow 15-22 , reducer elbow 22-28 , reducer elbow 28-35 , reducer tea 12-15 , reducer tea 15-22 , reducer tea 22-28 , reducer tea 28-35 , outlet point oxygen surface , outlet point nitrous oxide surface , outlet paint medical air surface , outlet paint vacuum surface , isolation valve 15 mm conex , isolation valve 22 mm conex , isolation valve 28 mm conex , isolation valve brazing 15 mm conex for drayer , isolation valve brazing 35 mm conex , threaded rod 8 mm , washer & mm , nut 8 mm , slotted putti u type , saddle nut bolt washer , grinder wheel for metal rod & putti cutting , hammer drill beat 5 mm , hammer drill beat 6 min , screw 850 half threded , marshal grip (rawal plug) 6 mm 3510 , anker fastner 10 mm 6 inch for manifold , brazing rod , ladder 7 feet , manifold (4+4) nitrous oxide , fully automatic control pannel nitrous oxide , non return valve nitrous oxide , tailpipe nitrous oxide , manifold (1010) oxygen , fully automatic control painel oxygen , non return valve oxygen , tailpipe oxygen , paint golden yellow for oxygen & n20 , paint sky blue for air & vacuum , thinner for brush & hand clining , painting brush , teflon tape , valve box (2 gas) , valve box (3 gas) , valve box (4 gas) , area alarm pannel (2 gas) , area alarm pannel (3 gas) , area alarm pannel (4 gas) , air compressor with tank (500 ltr) 10 hp , air dryer with filter & regulatour , vacuum pump with tank (1000 ltr )10 hp , nacuum pump accessories

State Government

CTN :39562504 Due date: 15 Mar, 202515 Mar, 2025 50.0 Thousand
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - dept fishing vessel m v skipper ii; engine room safety alarm panel 230v ac 24 v dc; service provider
 Loading, Please wait...

Connect us via What's Up