Web Analytics Made Easy - StatCounter

Fire Detection Machine Repair Tenders

Get complete information related to latest Fire Detection Machine Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fire Detection Machine Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fire Detection Machine Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :44341415 Due date: 27 Mar, 202627 Mar, 2026 NA
Tender For supply of refurbishment of room flooding system of server room at sauw ins satavahana c c -refilling of hfc 227ea gas 1,1,1,2,3,3,3 hepta fluro propane, zero odp, stored pressure, gas , conventional gas release panel with battery backup and cross zoning facility 2-zone with fire ext automatic mini intuitive fk-5-1-2 300gm ss sp red 79 c with nrv , ms container strap for mounting and fixing the agent containers to the wall , ul container strap for mounting and fixing the agent container to the wall , valve assembly and arrangement for supervisory switch connection for monitoring cylinder pressure, a pressure gauge with a safety burst disc and a safety cap 25 bar , pressure gauge cum switch for monitoring the cylinder pressure 0-60 bar, 22. 50 bar switch point pressure switch wasco switch point 5bar 72. 5 psig imp with fire ext automatic wm fk 5-1-12 4kg , hydro static pressure test 50 bar, inverted baker test, helium leak detection test, epoxy powder painting, dismantling, commissioning charges , conventional optical smoke detector with double dust trap chamber design, optimized performance using internal algorithm, central led for 360 status visibility, compiles to en 54-7 standard , conventional rate of rise heat detector, heat alarm threshold temperature 58 c central led for 360 status visibility, complies to en 54-7 standard and approved by lpcb, vds , installation and delivery charges

CTN :44327346 Due date: 08 Apr, 202608 Apr, 2026 NA
Tender For supply of spares for fire alarm system d d - conventional manual call point make apollo fire detectors ltd model orbis part no 55100 031 apo , conventional multi sensor with base make apollo fire detectors ltd model orbis part no orb oh 13003 apo , conventional heat detector with base make apollo fire detectors ltd model orbis part no orb ht 11013 apo , conventional optical smoke detector with base make apollo fire detectors ltd model orbis part no orb op 12003 apo , intelligent input output module make apollo fire detectors ltd part no sa4700 102apo , addressable manual call point make apollo fire detectors ltd part no sa5900 908apo , addressable sounders make apollo fire detectors ltd part no 55000 001apo , addressable multi sensor with base make apollo fire detectors ltd model soteria part no sa5100 700apo , addressable heat detector with base make apollo fire detectors ltd model soteria part no sa5100 400apo , optical smoke detector with base make apollo fire detectors ltd model soteria part no sa5100 600apo

CTN :43855489 Due date: 12 Mar, 202612 Mar, 2026 NA
Tender For corrigendum : supply of bottle solo , em3090b-1312 -22 cam type single pole on off switch 10ampsis 60 , em3090b-1312- 47 power factor meter 05-1-0541svctr 200sa , em3090b13150230 230v ac 40va bulb , em3090b-3 nwns16 hrc fuse link 16 amps , em3090b-406390a- 00500 navtex recfiver sailor 6390 , em3090b -7000000-555 mgl 5 dgnss antenna , em3090b-a-sc-11277 triple pole mouloed case circuit breaker rated 400a , em3090ba -sc 11668 tp mccb rated 160a , em3090b-a-sc-13103 undervoltage release 220240v ac for nsw 100 nsx630 , em3090b-b sc-00163 pushbutton green colour with 1no contact , em3090b-b-sc-00166 pushbutton red colour with inc contact , em3090bb sz 11343 single pole two way without off rotary switch rated 6a , em3090b -dfs96 phase sequence indication 415v , em3090b e-sc 01522 voltage monitoring relay 3ph 200-480v ac , em3090b-e -sc04075 triple pole miniature circuit breaker rated 32a , em3090b-g-ae-0010 phase sequence indicator 50-500vacsize 96x96mm , em3090b-g-rs-00103 kilowattmeter 0-500kw 3 wire 2 elements , em3090bg-rs-00109 kilowattmeter 0-125kw3 wire 2 elements 96x96mm 240 deg , em3090b-g-rs -00163 kilowattmeter 75-0 500kw 3 wire 2 elements , em3090b-g -rs 00643 pf meter 0 0-1-0 5rm at 0 8ctr 300 5a380v 50hz , em3090b-h tc-1123 indicating lamp integral led red colour 230v , em3090b h-tc-1124 indicating lamp integral led yellow colour 230v , em3090b -m-di-0099 1ph double wound transformer 380 24v 50hz 5va , em3090b me afas-jb1 junction box for sensor , em3090b me-afds-ava1 audio visual alarm nexus 120 db , em3090b me-afds-db32 ip32 detector base with short circuit isolator , em3090b-me afds fd addressable flame detector ir tri-spectrum , em3090b-me-afds-ishd i s combined detector atex certified , em3090b -me afds mcp42 ip42 manual call point , em3090b-me-afds-mcp42pc ip42 manual call point protection cover , em3090bme-afds mcp66 ip66 manual call point , em3090b-m eafds mcp66pc ip66 manual call point protection cover , em3090b-me-afds-pishd protection for detector , em30908-me-afds-psd protection for detector , em3090b -me-afds-pshhdd protection for detector , em3090b me-afds pshld protection for detector , em3090b-m e-afds psu power supply internal change over backup battery , em3090b meafds-sd addressable smoke detector dual function , em3090b-me-afds-shhd addressable combined detector dual function plus , em3090b-me afdsshld addressable combined detector dual function plus , em3090b-me-afds-tmtimer module , em3090b-t2000 -0120 reverse power relay 415 480v l lsa , em3090b-t63801806 pcb assy- trigger , em3090b t65825812 mooulator pcb assy 2skw , em3090b t91003496 magnetron 25kw , em3090b-u-mw-00044 smps50w ip 230v acop 24v dc , em3090b-xb7 ev03 mpn indicating lamp integral led green colour 230v , em3090b-xb7-ev05 mpn indicating lamp integral led yellow colour 230v , em3090b-xb7-ev06 mpn indicating lamp integral led blue colour 230v , em3090b-yl40 combined audio visual alarm unit , em3100b me1221kf6000 breakerclrcultmouldedcase 300awith rearconnec , em3100b me1226ks1005 breake r circuit moulded case 100a with rear connec //bid details2 / 57

CTN :44305047 Due date: 13 Mar, 202613 Mar, 2026 NA
Tender For supply of ec6025d-5200112-00a testifire multi detector tester , ec6025d-5200114-00a testifire smoke capsule

Central Government And Public Sector

CTN :44297733 Due date: 24 Mar, 202624 Mar, 2026 79.15 Lacs
Tender For supply of sitc of addressable fire alarm control panel having min. 2 loops inbuilt expandable up to 5 loops with touch screen or lcd display. , sitc of extra loop card suitable for above panel. , sitc of repeater panel. , sitc of addressable control module. , sitc of addressable monitor module. , sitc of intelligent addressable microprocessor based multi criteria smoke and heat detector. , sitc of twin red led response indicator. , sitc of addressable manual pull station. , sitc of addressable sounder cum strobe with built in fault isolator. , supplying and fixing of 2 x 1. 5 sq. mm pvc insulated and pvc sheathed frls copper conductor armoured cable. , providing and fixing of photoluminescent acrylic exit signage board 300 mm x 250 mm. , comprehensive maintenance addressable fire detection and alarm system for first year after completion of 1 year warranty period. , comprehensive maintenance addressable fire detection and alarm system for second year after completion of 1 year warranty period. , comprehensive maintenance addressable fire detection and alarm system for third year after completion of 1 year warranty period. , comprehensive maintenance addressable fire detection and alarm system for fourth year after completion of 1 year warranty period.

CTN :43833267 Due date: 11 Mar, 202611 Mar, 2026 NA
Tender For corrigendum : mo(v)/cpro/n1/25vecc001 for procurement of gshb, beu, agds, rukmani and sirs spares - motor pinion 20t, roll bar (aft), relay 24v, 1a,3changeover, choke -tl (115v, 60hz), electrolytic capacitor 100 f 63 or 64 vdc, roll bar (forward), capacitor 3 m f/400v, translucet cover-2 (blue), translucet cover-1 (blue), dimmer choke drg.no.ga-19-215715-a3, push button red button, anti condensation heater 230v ac 500w, anti collision light lamp type a7079b-24, 28v,40w, anti collision light, synchro 18ct 4b, connector ms 3108e 31 7s/ms3108f, neon lamp 110v/115v, connector ms 3106 f36-10p, connector ms 3106 f32 7s, anti backlash gear 150t, gasket size 36 ms3102, translucent cover-1(blue), connector ms 3102r 36 10p, connector ms 3108 e36-10s/ms 3108 f36-10s, rotary switch 3 pole on/off, capacitor 1200 m f/250v, bar illumination select switch, power relay 24v,5amp 2changeover type mpc/24d, capacitor 170 m f/250v, ic 1524, indicating lamp holder with red lens type il-18, motor tacho gear head, power transistor 40410 2n6193, translucent cover-2(blue), power transistor 40411, diode type 1n 4007, ball bearing no.6007-2rz/2rs1(drg no.e-132-10596), connector ms 3102 r 32-10p, ic 555, retainer ring, diode 2sme, tantalum electrolytic capacitor, 100uf, 20v, connector ms 3106f-16s-4s, gasket size 32 ms 3102, diode, gasket size 16, gasket size 32, wired enclosure with one channel, hand held key gun key loader, analog addressable ionisation smoke detector with base, smoke detector tester, analog addressable manual call point, conventional ultraviolet flame detector, heat detector tester, 2 core 2.5 sq mm screened unarmored lfh cable, 2 core 2.5 sq mm screened cable, rj 11 connector, spectrum analyser, power analyser, 3 pin round shell recept.plug, 7 pin ms connectors ms3106f-16-1p gp c&c tb, central indicating assembly ca5427, audio alarm unit assembled mounted, radiation survey meter with 6v battery (portable) order no 3, contamination monitor with 6v battery (portable) order no 30, digital pocket dosimeter pm1203

CTN :44261505 Due date: 23 Mar, 202623 Mar, 2026 NA
Tender For supply of procurement of 22 lines of mafi general spares -sor_2067item1 ni mh 3 6volt battery , sor_2067item2 server atms , sor_2067item3 500gb hdd for server , sor_2067item4 hpe dl360 gen10 sff dvd rw for server , sor_2067item5 ntp80plus triple port network time server , sor_2067item6 tape drive 1 2 with drf server , sor_2067item7 hp 500gb hdd for workstation , sor_2067item8 0 5 panel clocks , sor_2067item9 datis , sor_2067item10 workstation , sor_2067item11 vhf uhf portable radios , sor_2067item12 smoke sensor , sor_2067item13 smoke detector interface unit , sor_2067item14 power cable , sor_2067item15 data cables , sor_2067item16 workstation for asd , sor_2067item17 smps 350w compatible , sor_2067item18 cmos 8 bit microcontroller , sor_2067item19 smps 550w compatible , sor_2067item20 ethernet to spi interface board , sor_2067item21 battery , sor_2067item22 serial timekeeper chip ht 1380

CTN :44283830 Due date: 13 Mar, 202613 Mar, 2026 NA
Tender For procurement of aerosol smoke detector tester spray

Central Government And Public Sector

CTN :44270819 Due date: 21 Mar, 202621 Mar, 2026 6.06 Lacs
Tender For supply of replacement of obsolete fire alarm panels under kozhikode ba : : -sitc of afds control panel of 6 zone , sitc of afds control panel of 8 zone , sitc of afds control panel of 12 zone , sitc of afds control panel of 24 zone , sitc of smoke detector , sitc of heat detector , supplying and fixing battery 12 v, 7 ah

State Government

CTN :44281908 Due date: 17 Mar, 202617 Mar, 2026 NA
Tender For supply of isi mark gi pipe all fittings 25 mm dia , lowering laying and jointing gi pipe 25 mm dia , isi mark gi pipe all fittings 40 mm dia , lowering laying and jointing gi pipe 40 mm dia , isi mark gi pipe all fittings 50 mm dia , lowering laying and jointing gi pipe 50 mm dia , isi mark gi pipe all fittings 80 mm dia , lowering laying and jointing gi pipe 80 mm dia , isi mark gi pipe all fittings 100 mm dia , lowering laying and jointing gi pipe 100 mm dia , isi mark gi pipe all fittings 150 mm dia , lowering laying and jointing gi pipe 150 mm dia , providing supplying lowering laying and jointing isi mark gi pipe 200 mm dia , two coats of enamel paint over and one coats of red oxide primer , brass quartzoid sprinklers 68 degree , drain assembly 25 mm dia , ss flexidrop 1000 mm long , ss rosset plate , hydrant valve type a , short branch pipe , hose reels drum , hose boxes single door , hose boxes double door , rrl hose pipe , 4 way fire brigade inlet , 2 way fire brigade inlet , wrapping 4mm thick protection coating 150mm , wrapping 4mm thick protection coating 100mm , ms steel for supports , core cutting 150 mm , core cutting 100 mm , core cutting 80 mm , excavation for pipe line , rcc pipe 300 mm dia , lowering laying and jointing rcc pipe 300 mm dia , refilling of trench , diesel driven pump , electric driven main fire pump , jockey pump , fire pump control panel , pressure vessel , sluise valve 200 mm dia , sluise valve 150 mm dia , sluise valve 80 mm dia , sitc butterfly valve ci body 150 mm dia , sitc butterfly valve ci body 100 mm dia , sitc butterfly valve ci body 800 mm dia , double flanged metal bellows 150 mm dia , double flanged metal bellows 80 mm dia , y type stainer or foot valve 150 mm dia , y type stainer or foot valve 80 mm dia , sitc nrv non return valve 150 mm dia , sitc nrv non return valve 80 mm dia , air release valve , cable end termination and connection 1 point 5 sqmm , cable end termination and connection 4 sqmm , cable end termination and connection 16 sqmm , cable tray system , pressure gauge , pressure switches , ms steel for supports , addressable 1 loop main panel , addressable 2 loop main panel , single loop card , photoelectric smoke heat multi detector , photoelectric smoke detector , manual call point , addressable sounder , computer based software , isolator base , 1 point 5 sqmm 2 core red cable armd , 12v 7ah batteries for panel , abc powder type fire extinguisher 6kg , co2 type fire extinguisher 4 point 5 kg , emergency exit board , fire hydrant board , fire alarm call point board , abc extinguisher board , co2 extinguisher board , pass or race board , assembly point board , left side man running with arrow tape board , anti skid tape , evacuation plan , fire buckets , emergency light with exit sign , maintenance of equipment 1st year , maintenance of equipment 2nd year , maintenance of equipment 3rd year , legal and liasoning charges , rcc water tank 50000 ltr , rcc frame structure for pump , cc grade m25 , mass cement concrete in 148 proportion , tmt fe500 steel , pvc pipe 63 mm dia , pvc pipe 75 mm dia , lowering laying and jointing pvc pipe 63 mm dia , lowering laying and jointing pvc pipe 75 mm dia
 Loading, Please wait...

Connect us via What's Up