Web Analytics Made Easy - StatCounter

Fire Detection Machine Spares Tenders

Get complete information related to latest Fire Detection Machine Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fire Detection Machine Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fire Detection Machine Spares Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45147903 Due date: 21 May, 202621 May, 2026 NA
Tender For supply of fire detection system (fds) not getting reset from fds control panel and showing autroroom tcp and operation zone warning. suspect malfunctioning of bsr-310c pcb push buttons. defect to be rectified and proved with satisfactory operation.

Central Government / Public Sector

CTN :45153516 Due date: 18 May, 202618 May, 2026 NA
Tender For supply of goods, n & s aspirating type fire/smoke detection with alarm system to rdso specrdso/2008/cg-04/rev-05 for train 18 model-ns-hochiki-1060.01 spare part. four zone conve ntional fire alarm panel with gsm. batteries excluded with power wiring, part no. ns-train18-cp-fire panelpcb, operating voltage: 24vdc, 3a power consumption: suitably <3w no of zones: 04 lcd disp lay/rs485/keypad program gps/gprs. make: n&s solutions. [ warranty period: 30 months after the date of delivery ] ]

State Government

CTN :45143608 Due date: 15 May, 202615 May, 2026 13.73 Crore
Tender For removing, shifting & re-installation along with programming of fire alarm detection panel & its associated devices installed at msebhcl office at 3rd & 4th floor hsbc bldg, fort mumbai to newly created msebhcl office at 3rd & 4th floor of lic gulestan bldg. fort, mumbai

CTN :44099758 Due date: 13 May, 202613 May, 2026 NA
Tender For bid to ras supply of rrc for addressable fire detection system onboard in ships and yard crafts at nsry karwar -repairs to main control panel , repairs to repeater panel , repairs to control cards , repairs to ionization smoke detector , repairs to multi sensors , repairs to temperature heat detection sensor , repairs to flame detector , repairs to manual call point , repairs to front panel switches , repairs to alarm bells lights hooters , repairs to internal circuit wiring , repairs refurbishment of ups , repairs to cabling from main control panel , reprogramming of the pcbs

CTN :45141010 Due date: 30 May, 202630 May, 2026 NA
Tender For provision of automatic fire detection and alarm system with aspiration type air sampling detector at 03 stations, namely ratnagiri, kankavali, and kudal, covering all s&t rooms of stations provided with panel interlocking and provision of aspiration type air sampling detectors at 10 goomties. the work also includes interfacing with the existing afdas at goomties located at kolad, mangaon, veer, goregaon, and indapur stations in ratnagiri region of konkan railway

Central Government/Public Sector

CTN :45114129 Due date: 22 May, 202622 May, 2026 25.00 Lacs
Tender For tender for supply of sitc and maintenance of addressable fire alarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi

Central Government/Public Sector

CTN :44789665 Due date: 18 May, 202618 May, 2026 28.24 Lacs
Tender For corrigendum : supply of fire detection and alarm system powergrid silchar sub station : : - smoke detection system , fire detection and alarm system for control room , fire detection and alarm system for switchyard panel room of 9 m length , fire detection and alarm system for 400kv gis hall , fire protection system for local relay room for gis , indoor fire detection and alarm system for fire fighting pump

CTN :45072255 Due date: 25 May, 202625 May, 2026 NA
Tender For supply of fire alarm detection system - addressable fire alarm panel-02 loops with lcd , addressable smoke detector with base , addressable heat detector with base , addressable manual call point , addressable or conventional hooter cum strobe , addressable control modules , addressable input or output module , addressable input module , response indicator , addressable loop isolator , installation charges

CTN :45025842 Due date: 28 May, 202628 May, 2026 NA
Tender For supply, erection, testing & commissioning of training simulator for fire fitting control panel with detection system at metro railway training academy, kolkata, as per specification with 2 years warranty[ warranty period: 24 months after the date of delivery ]

Central Government/Public Sector

CTN :45037331 Due date: 13 May, 202613 May, 2026 NA
Tender For supply of fire detection panel as per sanrok part no. 2ed-255-4284 or equivalent, suitable to sanrok automatic smoke/ fire detect ion with alarm system (fds) fitted in railway coaches as per rdso specification no. rdso/2008/cg-04 (rev-6) [ warranty period: 30 months after the date of delivery ]