Tender For supply of sitc of pigtail ofc - 1 meter , sitc of cat-6a cable , sitc of 19 inch 6 u rack , sitc of lan system , sitc of liu 12 port , sitc of patch cord cat-6 -1 meter , sitc of patch cord cat-6 -2 meter , sitc of patch cord cat-6 -10 meter , sitc of hdpe pipe , supplying and fixing io box alongwith base and cover plate , sitc of cctv camera with night vision - 5 mp , supply and fixing of cat-6 wire in pvc conduit , sitc of cctv camera , fire work sitc talk back slave station , sitc smoke detector with built in led , sitc 6 kg powder type fireextinguishers , citc 2 kg powder type fireextinguishers , sitc addressable manual call point complete as required. , civil works as per boq , cement work as pe boq , providing and laying in position cement concrete of specified grade , double charge vitrified tiles , centering and shuttering , steel reinforcement for r.c.c. work , smooth finishing of the exposed surface of r.c.c. work , brick work with common burnt clay , 12 mm cement plaster of mix , partition upto ceiling height , cement fiber board , frames of doors, windows, clerestory windows , isi marked flush door shutters , universal hydraulic door closer , structural steel work , polishing in high gloss matt finish melamine , bright finished brass hanging type floor door stopper , false ceiling with cove and design at all height , removing dry or oil bound distemper, water proofing cement paint , providing and applying white cement based putty , wall painting with acrylic emulsion paint , 2mm thick pvc mat finished on floor of approved design , ac duct made of wooden batten , sitc of vertical blinds , electrical works , wiring for light point etc , wiring for circuit , supplying and fixing following modular switch etc , supplying and fixing following modular switch socket , supplying and fixing following modular switchs , supplying and fixing modules , supplying and fixing following way , supplying and fixing miniature circuit breaker , miniature circuit breaker suitable for inductive load , supplying and fixing single pole blanking plate , supplying and fixing of following sizes of medium class pvc conduit , supplying and fixing suitable size gi box wih modular plate , frls pvc insulated copper conductor , frls pvc insulated copper conductor 2 , frls pvc insulated copper conductor3 , frls pvc insulated copper conductor,4 , 3x2.5 mm flexible wire for connection , wiring for group controlled , led 2x2 luminaire 36w , recess mounted led downlighter , wall fan with brush less direct current bldc motor , electrical earthing sitc crs radio station transmitter of 50 w fm set , sitc of self supported transmission tower , vhf transmitting antenna , low loss feeder cable with n connector , studio monitor (speaker) , on-air broadcast console/mixer with inbuilt phone in unit and usb , dynamic cardioid microphone , portable solid state field recorder , headphones , broadcast audio processor , dummy load with connector , extra lightening protection circuit , 19 equipment rack ht. 5 ft , mts/equivalent, work station with antivirus for 3 years , audio editing software , automation/scheduling software licence, condensor microphone with wind filter and arm stand , audio distribution amplifier , headphone distribution amplifier , 10 kva online ups with 30 minutes back up online iso certified, xlr 6 microphone junction box , professional audio/line cable , professional microphone cable , xlr connecter male and female, trs stereo connecter , professional on air studio light , digital clock with time , supply and fixing of work station table , supply and fixing of vob table , supply and fixing of discussion table l shape, supply and fixing of on air table and side table , supply //bid details 2 / 87
Tender For establishment of integrated analytical laboratory for demil plant - hot air oven, magnetic stirrer, heating cooling circulator, rotary evaporator with chiller and vacuum pump, ultrasonic cleaner, high speed orbital shaker, vacuum pump, peristaltic pump, benchtop ph meter with orp electrode & necessary buffers, electrode storage solution & electrode cleaning solution, dissolved oxygen meter, turbidity meter, bench top multi-parameter tester (conductivity, tds, salinity, ph), bod incubator, cod digestor system, vortex mixer, effluent sampling manifold (esm) with controlled cobustion chamber (ccc), analytical balance, laboratory balance, mini centrifuge machine, gyro shaker, melting point apparatus, electric bunsen burner, deep freezer, laboratory rrefrigerator, ultra-pure water purification system, muffle furnace, double distillation unit, probe sonicator, heating mantles, systematic design, partitions, equipment console with work and storage modules, chemical reagent console with work and storage modules, instrument console with work and storage modules, overhead storage console, extended office console, office console, file storage console, record management console, back positioning module, fire protection modules, fume closet, exhaust manifold, power reserve (40 kva), elemental (chnso)analyzer, inductively coupled plasma - mass spectrometer (icp-ms), microwave digestion system, amc cost for 1st year after expiry of warranty period, amc cost for 2nd year after expiry of warranty period, amc cost for 3rd year after expiry of warranty period
Tender For corrigendum : custom bid for services - rpnc252027 support service for swing extruder vfd installation-shifting, foundation and installation of power transformer- 1. the power transformer is to be installed by construction of new transformer foundation, dismantling/modification of surface, providing chain link fencing on all other 4 sides, cleaning and refurbishment of bay area is in the scope of contractor only. all necessary manpower, tools & tackles, shifting machinery like hydra/crane etc shall be in the scope of contractor only. 2. shifting of power transformer of 7.2 mva onan from store to site, loading-unloading, erection, site storage are in scope of contractor. 3. the basic data sheet and ga drawing of the proposed transformer is attached in scope only. 4. the bidder if required must construct bay width, height and fire walls as per relevant is/iec/oisd standards and site conditions such that adequate clearances for maintenance shall be maintained. bidder to submit the plot plan of equipment layout of transformer layout along with the bid. the bidder shall carryout the site visit for assessment of the available installation space. the total length of the transformer bay should be such that the radiator can be accommodated on either side of transformer tank in the specified bay width. 5. all necessary earth pit provisions, & fire barriers/wall modifications, provision of new hvws water sprinklerbased firefighting system having suitable capacity for protection against the fire & explosion as per the design of supplied transformer and applicable standards & direction of eic. provision of all necessary fire protection system for transformers shall be in the scope of lstk contractor. 6. construction of oil drain facility of transformer as per is standard and hookup with existing burn oil pit. 7. the erection to be certified by contractor as per its recommended procedures which is to be submitted prior to erection. qap for erection and site commissioning shall also to be endorsed by contractor. 8. all kind of lifting, rigging work for loading-unloading, erection work including supply of hydra/ cranes, lifting rigging materials, manpower, tools and tackles as required are in scope of contractor. 9. all kind of skilled, semi-skilled, unskilled manpower as per itc of transformer requirement will be in the scope of contractor. 10. erection includes entire vacuum by proper capacity of vacuum pump, for not less than 48 hours, or more if required as per the instruction of engineer in charge. 11. first filling up of the transformer oil at site, its filtration, site testing oil sample, any refiltration required during final commissioning shall be in the scope of contractor including all tools, tackles and including oil filtration machines. oil may be supplied in drums, which should be properly sealed during transportation and storage. seal shall be verified and opened in front of iocl representative before filling in transformer. contractor should have enough storage capacity for handling oil. filling the oil from drums to the transformer through suitable capacity of high-quality filter machine and filtration of the same to get desired bdv &ppm as specified by engineer in charge and transformer manual. 12. contractor must replace all the gaskets by new ones if required by engineer in charge. 13. the contractor shall arrange nitrogen cylinder required at site for above work. 14. contractor must repaint the transformer tank with two coats of anti-rusting good finish ltbs grey shade 631 of is:5 by spray painting if required and as per the direction of engineer in charge..