Web Analytics Made Easy - StatCounter

Fire Fighting Alarm System Tenders

Get complete information related to latest Fire Fighting Alarm System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fire Fighting Alarm System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fire Fighting Alarm System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :39731358 Due date: 08 Apr, 202508 Apr, 2025 NA
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; electrical system or installation, biennial comprehensive maintenance contract of fire alarm system installed at various location of trombay plants at rcf..

corporations/Associations/Others

CTN :39743952 Due date: 08 Apr, 202508 Apr, 2025 NA
Tender For e-tender for civil, interior works, modular furniture, chairs, electrical installation, data and telephone cabling, fire alarm systems, fire sprinkler systems, public address system for divisional office building at madurai, tamil nadu state.working premises

Central Government And Public Sector

CTN :39144860 Due date: 21 Mar, 202521 Mar, 2025 NA
Tender For corrigendum : tender for supply of resistance temperature transmitter and indicator - resistance temperature transmitter ( resistance to current converter) , make -elektra precision .input- rtd pt-200. temperature range 0-100 degree centigrade , output- 04 to 20 ma dc (two no of output) zero & span adjustable. power supply- 118 vac with connector. other detail as annexure-1.(bidder should comply one to one in specification as attached) , spare elektra ( earlier lektrolab ) make resistance temperature transmitter. input rtd pt.200. temp range- 230 - 320 degree centigrade. o/p- 04 to 20 ma dc. single output. other common details as per attached annexure-1. , spare elektra ( earlier lektrolab ) make resistance temperature transmitter. input rtd-pt.200. temp range- 0-320 degree centigrade. output- 04 to 20 ma dc with double isolated outputs. other common details as per attached annexure-1. , resistance temperature transmitter ( resistance to current converter) , make-elektra precision .input- rtd pt-100. temperature range 0-100 degree centigrade , output- 04 to 20 ma dc (two no of output) zero & span adjustable. power supply- 118 vac with connector. other detail as annexure-2.(bidder should comply one to one in specification as attached) , indicating alarm meter , make - m/s elektra precision systems , tag-flow indicating alarm meter , range-0-400 ft/sec , alarm -high , alarm relay-one for high alarm , input -4-20ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag-temperature indicating alarm meter , range-0-100 degree c , alarm -high , alarm relay-one for high alarm , input -4-20ma , mounting arrangement-1a , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- differential pressure indicating alarm , range- -15 to +25 gm/cm2 , alarm -high , alarm relay-one for high alarm , input -4-20ma , mounting arrangement-1a , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating alarm , range- 0-700 (squre root scale flow) lpm , alarm -low , alarm relay-one for low alarm , input -10-50ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- temperature indicating alarm , range- 0 to 70 degree c , alarm -low/high , alarm relay-one for high alarm and one for low alarm , input -4-20ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating meter , range- 0-6 (squre root scale) klpm , alarm -no alarm , alarm relay-no alarm , input -10-50 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- level indicating meter , range- 0-10 meter , alarm -no alarm , alarm relay-no alarm , input -4-20 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating meter , range- 0-10.7 meter / sec & 0-30 feet /sec , alarm -high , alarm relay-one for high alarm , input -4-20 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating meter , range- 0-10.7 meter / sec & 0-30 feet /sec , alarm -high , alarm relay-one for high alarm , input -0-4 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- pressure indicating alarm meter , range- 0-0.7 kg/cm2 , alarm -high/low , alarm relay-one for high alarm & one for low alarm , input -4-20 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , i

State Government

CTN :39692165 Due date: 25 Mar, 202525 Mar, 2025 NA
Tender For servicing and re commissioning of existing fire alarm systems at baranagar s.g.hospital, baranagar in the district of north 24 parganas.

Central Government/Public Sector

CTN :39641467 Due date: 31 Mar, 202531 Mar, 2025 1.93 Lacs
Tender For custom bid for services - yearly routine of fm 200 system-e-065: - yearly routines are falling due on fm-200 system of this unit. |routines to be carried out as per maintenance schedule and system to be proved for satisfactory operation. following jobs to be carried out as part of the routines: () after removal of solenoid valve from fm-200 cylinder head of the system, the following checks need to be carried out: electric remote cabinet opening |from remote and pneumatic release cabinets. () systems check- checks each electrical manual release unit for operation. (ii) check fire alarm and evacuation alarm lights and sounds. (iv) check that all ac are shut down or dampers are closed, if any. (v) check that all pneumatic actuator operates after pre-set time delay. (vii) check operation of discharge pressure switch and check indicator lamp. (viii) reset all pneumatic actuator, electrical actuators, discharge pressure switch and fire alarm system. (ix) pipe work/ nozzle to ensure that they are free from debris. (x) check dust caps are fitted. (xi) containers - check containers are safe mechanical damage, corrosion or unauthorized interference. (xi) check containers brackets are fitted and all bolts tightened. (xii) chek pneumatic actuation tubing is firmly fixed and all connections are |tight..

corporations/Associations/Others

CTN :39575918 Due date: 26 Mar, 202526 Mar, 2025 69.58 Lacs
Tender For modernisation works including civil, interior works, modular furniture,chairs, electrical installation, fire alarm systems, data, telephone cabling, staircase, toilet renovation in branch office building at vandiperiyar under kottayam division

corporations/Associations/Others

CTN :39557424 Due date: 26 Mar, 202526 Mar, 2025 NA
Tender For modernisation works including civil works, interior works, supply of modular furniture and chairs, electrical installation, fire alarm systems, data and telephone cabling, staircase and toilet renovation in branch office building at vandiperiyar under kottayam division.

Central Government/Public Sector

CTN :39549249 Due date: 25 Mar, 202525 Mar, 2025 NA
Tender For annual repair contract [arc] of m/s ravell make fire alarm systems for three years over mysore division.
 Loading, Please wait...

Connect us via What's Up