Tender For corrigendum : cmc of the existing fireprotectionsystem and fire detection system installed at various locations of deben mahata govt. medical college, purulia, including refilling of existing fire extinguishers ( 2nd call)
Tender For supply of spares and servicing of co2 fireprotectionsystem - control box , zone card , charger card , system card , cylinder limit switch , pressure switch , dc hooter , ac hooter , smoke detector , 1 divide by 2 double desh bsp die set , 1 double desh directional valve o ring set , 32 nb directional valve o ring set , benzo o ring set , 3 divide by 4 double desh nylon washer , 1 divide by 2 double desh nylon washer , control box charging pin brass , high pressure discharge hose pipe , barrel door interlock switch , barrel door lock , nrv , directional valve , 24 v 7ah batteries , service engineer mechanical , service engineer electrical , to and fro journey kolkatta to sainj kullu back by air taxi for two person , journey expenses to and fro from kolkatta to sainj kullu subject to actual
Tender For corrigendum : kiifb-fsh002-09 improving educational infrastructure in selected schools of the cost of kerala educational infrastructure works in ernakulam and thrissur dist. phase i-gups konathukunnu,thrissur.proposal of providing fireprotectionsystem-re-tender2
Tender For ssp bid for purchasing spare parts cum deputing service engineer charges for attending/repairing nitrogen injection fireprotectionsystem, make-ctr installed on 220kv,160 mva tri (bhel-make) at 220 kv gss ramgarh, jaisalmer.
Tender For corrigendum : supply of spares for co2 based generator fireprotectionsystem at power house of omkareshwar power station - lcd display fmz5000 320x240, fmz 5000 conventional detector module, fmz 5000 8 relay module, monitoring high pressure system loss (light barrier), zonal card (front panel fmz5000) bbf, co2 cylinder valve k-85-20, release device,e 24v-dc, note: 1) transit insurance shall be in the scope of the supplier.2) bidder should quote unit basic rate inclusive of packing, forwarding, handling and freight charges for f.o.r. omkareshwar power station in column no.5. 3) bidder shall quote unit cgst, sgst amount in column no. 6 &7 respectively for intra-state supply or shall quote igst amount in column no. 8 for inter-state supply. 4) bidders are requested to verify carefully the amount entered by them in respective column and the amount generated automatically through formulae before uploading it to the portal
Tender For corrigendum : supply of supply of material required for process upgradation in both units like cylinders, instrumentation of directional valves and associated component as per attached specification , testings on item no-1 , installation and commissioning of the material supplied in item no-1 , supply of material required for up gradation candi of fireprotectionsystem , test requirement like emioremc,climatic test,ivandv etc. on item no-4 , installation and commissioning of the material supplied in item no-4
Tender For providing of custom bid for services - line 10 per day per service engineer charges rate contract for pm and troubleshooting of agnice fireprotection pvt ltd make co2 fireprotectionsystem installed at gtg,custom bid for services - line 20 to and fro travel expenses per visit rate contract for pm and troubleshooting of agnice fireprotection pvt ltd make co2 fireprotectionsystem installed at gtg