Get complete information related to latest Flash Memory Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Flash Memory Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Flash Memory Tenders.
Tender For corrigendum : procurement of non rc spares for offline hach instruments at ntpcsolapur-, 10, m2697965520 , specification , laboratory items spares , part name , part number , display, lcd , 9457600, hach ott india private limited , equipment manufacturer , 300x600 pixcels,qbd1200 , 20, specification , m2697218232 , pcb main board , "item description mithout compact flashmemory, manufacturer: thermo fisher manufacturer part number:qu040.5000, model number ohss-42 ", 30, specification , m2697965552 , laboratory items spares , part name , part number: , top housing assembly , 9599000, equipment manufacturer , hach , or 1900 , 40, specification , m2697965521 , display, hqd benchtop , 9245700, laboratory items spares , part name , part number , equipment manufacturer , cd 440 x 160 dots dr1900 , 50, specification , m2697965522 , hach ott india private limited , aboratory items spares , part name , part number , battery, alkaline , 1938004, equipment manufacturer hach ott india private limited , type aa voltage: 1,5 vdc, pk/4 , 60, specification , m2697965399 , part name , part number , laboratory items spares , equipment manufacturer , aa nn service calibration kit, 21000. , 2980700, hach ott india private limited , equipment name , turbidity meter , equipment model , 21000, additional information , hsn:90279090 , 70, m2697965482 , specification , laboratory items spares , part name , conductivity probe, ,
Tender For supply of 6 axis deformity /fracture correction system - system should consist of a six axis frame that can be used with any ring fixation parts & should be assisted by computer software for achieving precise d eformity correction, with residual deformity correction feature. a frame should include the following parts: 1 )strut assembly for deformity correction : 6 nos, 2) ring connection plate assembly %u2010 straight: 6 no s , 3) ring connection plate assembly %u2010 z shaped : 3 nos, 4) strut labels %u2013 set of six : 1 set, 5 ) x ray markers for strut %u2013 set of 6 : 1 set a frame shall be constructed out of above parts duly supp orted with following instrumentation: 1) combination wrench 12 mm : 2 no., 2) combination 8 mm : 2 no. , 3) allen key : 1 no. ,4) measuring device : 1 no. ,5) container : 1 no. software duly supporting the analytica l ability to measure bone positions & should be able to make complex mathematical evaluations thereby off ering prescription for a patient to adjust the struts lengths on day to day basis, for achieving correction of d eformity at the end of the treatment period. the software should provide for residual deformity correction. the software should also have the ability to be placed on any windows based computer system & should n ot require any internet connection. general specifications 1) the frame should be a six axis, computer soft ware based external fixation device to be used for a wide range of applications for fracture reduction & def ormity corrections of lower limbs, upper limbs, foot & knee. 2) the struts should have the ability to provide compression or distraction of every 0.50 mm 3) the struts should offer both %u201cgradual correction mo de%u201d & %u201cfast strut%u201d mode. 4) the struts should be able to work with supports of any e xternal frame of any geometry, including 5/8 rings. 5) the struts should not have any predefined places of f ixation to support & should offer freedom to be fixed to the stabilization supports, such as rings, 5/8 ring, p osts, connection plates etc. 6) the software of the apparatus should have the flexibility of being placed on any windows based laptop or desktop & should not require any internet connection for usage. 7) the softw are should have the ability to work with the x%u2010ray images which are inserted into the software for ev ery case. 8) the software must have the protection from human error with the data input. 9) the software must incorporate standard tracing of anatomic and mechanical axes of bone fragments, planning and visua lization. 10)the software should have the facility of showing the virtual (real) position of fragments after t he treatment. [ai (2024-25) , item code no.s-61125, sl no.1380 ]