Get complete information related to latest Flood Control Wall Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Flood Control Wall Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Flood Control Wall Tenders.
Tender For tender for supply of sitc of air conditioner : : -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1391 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters auto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply. the indoor unit shall be suspended from the ceiling using threaded rods- including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required. , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealedscrollrotary compressor and eco friendly refrigerantinitial charge of refrigerantcondensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply. the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floorlaying and interconnection of standard-length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required. necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no. 1 2 , supply laying of 4c x 2.5 sqmm frls pvc insulated 1.1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1.2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required. , supply and fixing of 75mm dia minimum 1.8mm thickness pvc covering pipe using necessary bend collor clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25x25x5mm l angle frame including clamps bolts nuts vibrating dampers as required for mounting of outdoor unit. , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar to match for the surrounding as required after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling.
Tender For construction of protection wall and widening of existing inspection path at supplementary drain from rd 14100m to rd 16436m for the year 2025 26.
Tender For corrigendum : supply of 28 hp heat pump outdoor vrv or vrf , 26 hp heat pump outdoor vrv or vrf , 4 way 3. 0 tr vrf cassette indoor , 4 way 2. 0 tr vrf cassette indoor , 4 way 1. 6 tr vrf cassette indoor , 4 way 1. 3 tr vrf cassette indoor , 4 way 1. 0 tr vrf cassette indoor , 1. 6 tr vrf hi wall split indoor , 1. 0 tr vrf hi wall split indoor , 4 way 2. 0 tr 5 star cassette ac , 2. 0 tr 5 star hi wall split ac , 1. 5 tr 5 star hi wall split ac , installation of vrv or vrf outdoor , installation of vrv or vrf cassette indoor , installation of vrv or vrf split indoor , installation of cassette ac , installation of hi wall split ac , refrigerant piping 34. 9 mm , refrigerant piping 31. 8 mm , refrigerant piping 28. 6 mm , refrigerant piping 22. 2 mm , refrigerant piping 19. 1 mm , refrigerant piping 15. 9 mm , refrigerant piping 12. 7 mm , refrigerant piping 9. 5 mm , refrigerant piping 6. 4 mm , additional copper pipe for cassettre ac , additional copper pipe for split ac , drain pipe 32 mm , drain pipe 25 mm , control and transmission wiring , control wiring for cassette and split ac , cable tray , outdoor stand for vrv or vrf , outdoor stand for cable and split ac , stabiliser 5. 0 kva , stabiliser 4 kva , core cutting
Tender For sh construction of pcc edge wall at rd 0/0 to 0/650 construction of pcc retaining wall at rd 0/085 to 0/105 interlocking paver pavement km 0/175 to 0/240 construction of v shape drain from rd 0/085 to 0/240 and metalling/tarring in km 0/0 to 0/175
Tender For up-gradation of tikker manoh via jakhyol, ramhera, sulkhan , dhirwin road km 0/000 to 12/195 under nabard ridf-xxx (sh:- removal of formation deficiency, c/o r/wall & gabions wall , m/t works, cc pavement ,pcc, u & v- shape drain, cross drainage work, road furniture from km 0/000 to 12/195) including 5 years maintenance.
Tender For construction of link road from harizan basti badiyana km 0/0 to 0/240. (sh:- c/o pcc edge wall at rd 0/0 to 0/650, c/o pcc retaining wall at rd 0/085 to 0/105, interlocking paver pavement km 0/175 to 0/240, c/o v-shape drain from rd 0/085 to 0/240 & metalling/tarring in km 0/0 to 0/175).
Tender For widening and improvement of kudhiar masiana road from km 0/0 to 12/0 under nabard ridf-xxviii. (sh:- balance work of construction of sub grade, c/o retaining wall/breast wall, metalling/tarring (gsb, wmm, bm & 25mm thck sdbc), cc interlocking paver block, u & v shape drain, kilometre stone & sign boards, c/o parapet, providing and fixing w-metal crash barriers) under nabard- ridf-xxviii.
Tender For repairing rain water drain near entrance gate of kabutari inspection bunglow and repairing compound wall behind flood cell at kabutari dam of kabutari irrigation scheme
Tender For improvement of black spot on rohru sungri bhali taklech nogli road km. 27/000 to 80/000 (sh:- c/o wire crate r/wall at rd 63/610 to 63/630 and v-shape drain in km. 63/390 to 63/600)