Web Analytics Made Easy - StatCounter

Floodgate Tenders

Get complete information related to latest Floodgate Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Floodgate Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Floodgate Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :39521610 Due date: 24 Mar, 202524 Mar, 2025 NA
Tender For corrigendum : 21/2024-25 purchase of laqshya instrument - purchase of instrument ( laqshya), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, fetoscope - technical specification of infant fetoscope should be 135 75mm weight should be up to 350gm should be 40cm h20 presser limiting valve inspiratory resistance should be 5cmh2o (at 50l/min), delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on

corporations/Associations/Others

CTN :39761945 Due date: 04 Apr, 202504 Apr, 2025 49.55 Lacs
Tender For procurement of pway materials and tools and equipments for maintenance of track - red flags , green flags , keying hammer for mk v ercs , alloy spanner , adjustable spanner , hammer 2kg , plate screw tubular spanner , keymen bag , safety shoe , safety jacket , safety helmets , rain coat , whistle thunderer , tri- colour hand signal lamps or rechargeable led torch , safety chain and padlock , number plate 15 cm square , banner flag red , post for exhibiting red banner flag , spade or powarh , mortar pan , wall clock , pick axe , water pot or bucket , rail drilling beat 31.5 mm dia , erc clip applicator , punji or wire claw , rail drilling beat 26.5 mm dia , track jacks hydraulic 15 ton capacity , abrasive rail disc cutter , steel c- clamps with fittings , rail drilling beat 18 mm , shovel , rail tong , abrasive rail cutting disc , measuring tape 30 m , measuring tape 5 m , chamfering kit , prc sleepers lifting shifting chain , joggled fish plate rdso drg no t 5849 , rail dolly , umbrella , fish plate 1m long for 60 kg rail rdso drg no 5916 , rail drilling machine , crowbar dia 25mm 5 feet long , rail thermometer , continuous rail thermometer , wooden block of hard wood , versine measurement kit , track cum gauge level , track cum gauge level for crossing and check rail , straight edge 1 m long made from special type of steel , straight edge 10 cm long made from special type of steel , off track tamper , dragon torch , caution board stand , speed indicator board 10 kmph , speed indicator board 15 kmph , speed indicator board 20 kmph , speed indicator board 30 kmph , speed indicator board 45 kmph , stop indicator board , mannual erc toe load measuring device , digital erc toe load measuring device , grease gun 5kg , allen key box , emary paper , lubricating oil , pwi kit , graphite grease , cleaning brush jute , cleaning brush steel , grass cutting machine , hand rammer , rope , jim crow , wooden handle for pick axe , wooden handle for powrah , gangboard with angle , pesticide for grass damage , pesticide sprayer machine with chargeable battery , tent for using on site , nut bolt dia 25mm 230mm long with washers each bag will contain approx 35 no nut bolt , hyadrulic rail tensor

CTN :39695241 Due date: 19 Apr, 202519 Apr, 2025 NA
Tender For e-bid for the finalization of rate contract for the procurement of diagnostic & therapeutic items for cardiac cath lab for the year 2025-27 group -b - ecg electrodes of high quality material to minimize interference and signal distortion during prolonged cardiology procedurest (fda/ce approved), manifold with two side ports for ptca (fda/ce approved), manifold with three side ports for ptca (fda/ce approved), teflon coated guide wires (j-tip & straight-tip) standard length-145 or 150cm (fda/ce approved), teflon coated guidewires(j-tips & straight-tip) exchange length-260 or 300cm (fda/ce approved), trans femoral introducer sheath with mini guide wire and puncture needle (fda/ce approved), long introducer sheath (20-50cm long) (fda/ce approved), extra-long introducer sheath (>50 cm) (fda/ce approved), trans radial introducer kit with mini guide wire and puncture needle (fda/ce approved), trans radial coronary diagnostic catheter (fda/ce approved), syringe for pressure injector-150ml with pressure tubing compatible with the available system in the cath lab (medred-mark-7) arterion, high pressure connecting tubing up to 50 cms long for pressure syringe, act cartridges compatible with the available machine in the cath lab (sonoclot-sienco-inc. & medtronic), diagnostic coronary angiography catheter(judkins type-left and right) (fda/ce approved) all sizes, diagnostic coronary angiography catheter(amplatz type-left and right) (fda/ce approved) all sizes, pigtail catheters (fda/ce approved), short pigtail for pericardiocentesis, diagnostic multipurpose catheters (fda/ce approved), nih catheter (fda/ce approved), ima catheter (fda/ce approved), ptca inflation device-analog display (balloon inflation device analog display, 30 atm pressure with tubing and 3 way stopcock) (fda/ce approved), y-connector set with extension tubing tuohy burst, pci needle and 3-way, special y-connector set with both fixed and haemostatic valve with upto 10 fr inner diameter, pci needle with/without torquer device, disposable plastic sterile luer lock syringer for angiography and ptca (leur lock), large lumen ptca guiding catheters of 5 to 8 fr sizes-fda approved, large lumen ptca guiding catheters of 5 to 8 fr sizes-ce approved, brk needle (fda/ce approved) for paediatrics/adults, patch electrodes for defibrillation compatible with the available machines in the cath lab(nihon-cohden & lifepack-20, iabp balloon catheter (fda/ce approved) compatible with the available machine (maquet) in cathlab, embolic protection (distal protection) device (epd) for ptca (fda approved), embolic protection (distal protection) device (epd) for ptca (ce approved), manual thrombosuction catheter for ptca (fda approved), manual thrombosuction catheter for ptca (ce approved), radial artery compression device, cross over arterial sheaths(fda approved), snare loop (fda approved), snare loop (ce approved), micro grabber (fda approved), micro grabber(ce approved), intra vascular retriever snare of various sizes with single foldable loop, intra vascular retriever snare-two loops (gooseneck type), intra vascular retriever snare-three or more loops (gooseneck type), pericardiocentesis kit (fda/ce approved), pigtail catheter with multiple markers (fda approved), rotalink plus system, rotalink pro system, rotalink guidewire, intracoronary pressure wire (ffr) for ptca-compatible with abbott vascular, ivus catheter for coronary interventions compatible with abbott vascular, ivus hd compatible catheter for coronary interventions, pharmacological hemostasis topical dry pad/bandage based mechanism, micropuncture needle with stainless steel guidewire for adults, paediatric & neonatal use, micropuncture needle with hydrophilic guidewire for adults, paediatric & neonatal vascular access, introducer sheath for use in neonates, mullins sheath with side arm (4-14 fr), percutaneous transluminal valvuloplasty balloon (compatible with 5 fr-7 fr, 0.018-0.035 inch wire) with app

Central Government / Public Sector

CTN :39671533 Due date: 22 Mar, 202522 Mar, 2025 NA
Tender For procurement of critical spares for m/s htpc make lpg carousals and allied equipments at gurgaon bp-i - dual flow gas stop valve , 5/2 solenoid valve , filling machine weighing module hardy 2080 , load cell (pcb 250 kg) , ethernet based slipring assembly , fm plc , speed variator for carousel system , carousel wheel without mountings assy [70166867] , central column bearing set , air distributor bearing set , vfd (with software ready to install) , optical sensor (wt) , optical sensor (wl) , input barrier 4 channel , output barrier 2 channel , barrier (excitation) , barrier (signal) , old pressure transmitter , power supply for safe area system
 Loading, Please wait...

Connect us via What's Up