Get complete information related to latest Flow Cabinet Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Flow Cabinet Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Flow Cabinet Tenders.
Tender For corrigendum : supply of lab investigations of human blood tests and collecting blood sample from central ayurveda research institute patiala- mochai (lab-lab) seeds, wooden lab stools, lab coat (npcil), water baths, angiography and dsa lab equipment, bi-plane (cath lab), bod incubator, angiography and dsa lab equipment, single plane (cath lab), ultra low temperature laboratory deep freezer, mobile food testing lab, laminar air flowcabinets or stations -
Tender For supply of mhv spares air circuit breaker, laminar air flowcabinets or stations, pt 100 duplex rtd (air circuit) (bhel), drip - leg drain, air circulator type electric fan as per is 2997, pre school uniform - pinafore, reciprocating air compressors - electric motor driven, split air conditioner including green ac, wall mount type (v2), servo control drive - servo motor operated lvc as per is 9815 (part 1), swing check type reflux valves for water works purposes (single door pattern) (v2) as per is 5312 (part1
Tender For supply of - wall table code one standing ht nine hundred mm, island table code three standing ht nine hundred mm, island table code eight sitting ht eight hundred mm, wall table code two standing ht nine hundred mm, emergency shower with eye wash, overhead storage size-l-750xd-375xh-675 mm, openable shutters with glass , overhead storage size-l-600xd-375xh-675 mm, openable shutters with glass, confined workplace for handling corrosive chemicals cwfh fumehood, full size locker overall size - 1980 mm x 910 mm x 480 mm - 18 compartments, open type rack of size l-1000x d-450xh-2100 mm, shoe rack of size l-1000 x d-450 x h-1200 mm, wall table code four standing ht nine hundred mm, wall table code five sitting ht eigth hundred mm, wall table code six sitting ht eight hundred mm, wall table code seven standing ht nine hundred mm, wall table code nine sitting ht eight hundred mm, wall table code ten standing ht nine hundred mm, counter code eleven , wall table code twelve standing ht nine hundred mm, wall table code thirteen standing ht nine hundred mm, wall table code fourteen standing ht nine hundred mm, wall table code fifteen standing ht nine hudred mm, laboratory chair medium rise with ring with castors wheels, back rest lab stool with castors wheels, cwbs-ns biosafety cabinet consisting of class ii a2 , cwbs-s biosafety cabinet consisting of class ii b2 , cwlf-v laminar flowcabinet vertical for research, cwlf-v laminar flowcabinet vertical for teaching, cwlf-anr anaerobic workstation, gas piping system consisting of cylinder holding bracket, gas piping system consisting of ss braided pigtail w safety rope, gas piping system consisting of cylinder manifold system, gas piping system consisting of dual stage regulator w relief valve, gas piping system consisting of non return valve, gas piping system consisting of half inch od x half inch bsp adapter, gas piping system consisting of half inch od ss tube, gas piping system consisting of half inch od union, gas piping system consisting of half inch od union tee, gas piping system consisting of reducing tee, gas piping system consisting of half inch od ball valve, gas piping system consisting of one quarter inch od ss tube, gas piping system consisting of one quarter inch od union, gas piping system consisting of reducer, gas piping system consisting of micron filter, gas piping system consisting of gas purification panel, gas piping system consisting of gas control box, gas piping system consisting of point of use regulator, gas piping system consisting of pp clamp w profile, gas piping system consisting of pp clamp w profile size one quarter inch od, gas piping system consisting of misc fittings, gas piping system consisting of gas bank shed, gas piping system consisting of vacuum pump
Tender For supply of various items for the dhr project entitled molecular biology applications research and diagnostic techniques - laboratory items, pc based true double beam uv-visible spectrophotometerspecification:1. optical system: czerny-turner mounting, single monochromator, double- beam system, 1,300 lines/mm, 240 nm blazed holographic grating 2. light source: deuterium lamp and tungsten-halogen lamp 3. detector: r-928 photomultiplier tube 4. wavelength range: 185 to 900 nm or higher 5. wavelength accuracy: 0.1 nm (656.1 nm) 6. wavelength repeatability: 0.05 nm 7. spectral bandwidth: 0.1, 0.2, 0.5, 1, 2, 5 nm in steps 8. resolution: 0.1 nm 9. stray light: max. 0.005 %t (220 nm nai) 10. mode: abs, %t, %r, 11. photometric range: -5 to 5 abs12. noise level: 0.00003 abs rms (500 nm) 13. wavelength slew rate: 14000 nm/min 14. wavelength scan rate: 4000 to 0.5 nm/min 15. below items must be supplied along with the main instrument:a) one pair of cuvettes, 10 mm path length, 3.5 ml volumeb) integrating sphere attachmentwavelength range: 220 nm to 850 nm or betteri) samples like powder, solid, colloidal sample, thin film etc are measured by using thisaccessoryii) minimum inner diameter of integrating sphere: 60 mmc) branded i5 pc with original os- 1 no, class ii, type a2 bio-safety cabinetspecification: 1. the bio-safety cabinets should be 4 feet width with front window must be a 10 sash opening and steel with smart coat interior 2. the bio safety cabinet must include dc motors. 3. the motor must automatically adjust the airflow speed without the use of a damper to ensure continuous safe working conditions, even without maintenance adjustments. 4. cabinet must use a pressure sensor (rather than anemometer) to detect pressure drop across the supply filter, rather than in just one point across the down flow. 5. the cabinet should display the inflow and down flow air velocities and must incorporate an led indicator, visual & audible alarm to indicate excessive hepa filters loading, blower failure, airflow speed failure, incorrect window position. 6. the front of the cabinet must be angled 10 to help minimize glare. 7. the cabinet noise level must be less than 65 db(a) for a 4-foot cabinet. 8. cabinet with lights on and fan at operating speed should consume less than 400 watts or less 9. the cabinet must automatically reduce fan/blower motor speed to 30% when the front window sash is in closed position to ensure reduced energy consumption when the cabinet is not is use. 10. uv light must be programmable to allow for specific exposure times from 0 to 24 hours. 11. the cabinet should have provision to fit taps for vacuum, water and non-combustible gas. 12. the bio safety cabinet should be nsf certified with listing on nsf website. 13. the bio safety cabinet should incorporate hepa filter of the class h 14 en 1822 or better and having minimum efficiency of 99.995% at 0.3 m particle size. 14. ventilation system exhaust and inflow air volume approx 300-350 cfm 15. audible and visual alarms for hepa filter failure, blower failure, airflow speed failure, incorrect window position. 16. the cabinet should be provided with fixed / adjustable height stand, uv light and one set of detachable arms rest and one / two electrical outlet. 17. the drain pan of the bsc should be made of stainless steel. the drain pan should not be painted, or power coated. 18. cabinet should be ce certified and declaration of moc should be provided. 19. port provision for clean and safe routing for vacuum tubing and cables throughthe side of the bsc for improved organization and work efficiency., vacuum ovenspecification: 1.volume(l): 60-802.temperature range ( c): rt+5-2503.temperature resolution ( c): 0.1(at 100 c)4.temperature variation ( c): (at100 c)5.heating power (w): 21006.vaccum range 0 ~ 1 atm7.timer: 1min ~ 99hr59min8.vaccum connector (mm): 109.venting connector (mm): 1010.inner size (mm): 400x400x40011.dimension (mm): 625x585x710, constant temperature incubators