Get complete information related to latest Flue Gas Duct Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Flue Gas Duct Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Flue Gas Duct Repair Tenders.
Tender For supply of material for ac system - fire damper fire damper with auto resetting, limit switches, indication lamps etc. , fire damper motorized actuator with single phase power supply for the above fire damper volume control dampers. , gss zinc coating 275 gms per m2 ducting complete with hangers supports, dampers, grilles, diffusers with and without vcd etc , variable air volume vav box complete with damper, differential pressure sensor, motorised damper, actuator, following air flow capacity 50- 990 cfm , variable air volume vav box complete with damper, differential pressure sensor, motorised damper, actuator, c air flow capacity 1000- 1990 cfm , variable air volume vav box complete with damper, differential pressure sensor, motorised damper, actuator, air flow capacity 2000 - 2990 cfm , insulation for pipe and valves - 150 mm dia, 75 mm thick , insulation for pipe and valves - 125 mm dia, 75 mm thick , insulation for pipe and valves - 100 mm dia, 75 mm thick , insulation for pipe and valves - 80 mm dia, 75 mm thick , insulation for pipe and valves - 65 mm dia, 75 mm thick , level gauges , air pressure switch , water differential pressure switch , flow meter , btu meter complete in all respect like provision of energy consumption measuring and data storing facility of energy consumption of at least 1 year with sufficient memory space. , temperature and humidity sensor , temperature and humidity indicator with sensor , occupancy sensor , co2 sensor
Tender For hiring of large capacity portable package air conditioning units with ducting forproviding better working environment by controlled localised cooling during repair ofreheating furnaces of mills and hot equipment of blast furnaces, converters, sinteringmachines and other enclosed vessels and large diameter pipes inside bhilai steel plantpremises.
Tender For dismantling and removal of existing ducting and supply, fabrication, installation, insulation, and aluminum cladding of new air conditioning ducting for ahus at wip, barc tarapur
Tender For supply, fabrication and installation of gss sheet ducting for exhaust and fresh air in main kitchen and laundry at the ashok hotel, new delhi.
Tender For supply of sitc of ductable split ac - supply of 3 tr ductable ac , supply of 1.5 tr ductable ac , itc of 3 tr ductable ac , itc of 1.5 tr ductable ac , wall bracket for out door , m.s. stand , sf of copper pipes , sf of drain pipe , sf of power cable , sf of 4p mcb enclosure , s installation of gss ducting , pf of supply air grill , sinstalling of m.s. cable trays
Tender For bid to ras supply of supply, erection, commissioning and testing of industrial air-cooling system , supply, erection, commissioning and testing of ducting with grill for industrial air-cooling system
Tender For tender for supply of shifting of pac units from jaisalmer to sardarpura and basni jodhpur - supplying , installing , balancing and commissioning of fabricated at site gss sheet metal rectangular/ round ducting complete with neoprene rubber gaskets , elbows , splitter dampers , vanes , hangers , support as per approved drawing and specifications of 0.63mm thick gss sheet etc complete as required. , supplying , installing , balancing and commissioning of fabricated at site gss sheet metal rectangular/ round ducting complete with neoprene rubber gaskets , elbows , splitter dampers , vanes , hangers , support as per approved drawing and specifications of 0.80mm thick gss sheet etc complete as required. , supplying , installing , balancing and commissioning of fabricated at site gss sheet metal rectangular/ round ducting complete with neoprene rubber gaskets , elbows , splitter dampers , vanes , hangers , support as per approved drawing and specifications of 1.00mm thick gss sheet etc complete as required. , sitc of gi volume control damper complete with neoprene rubber gaskets , nuts , bolts , screws linkages , flanges etc. as per specifications etc complete as reqd.. , supplying & fixing of powder coated extruded aluminium return air grills with louvers but without volume control dampers complete as required. , sitc of 4x16 sqmm pvc insulated pvc sheathed aluminum conductor armoured cable on the existing ms tray /walls with saddles/pvc of cables with glands etc. as required , sitc of 3x2.5 sqmm pvc insulated pvc sheathed copper conductor armoured cable for control wiring on the existing ms tray / walls with saddles/pvc thread/cable tie , screws etc. i/c end termination of cables with glands etc as required. , sitc of 40mm upvc pipe for plumbing work for drainage requirement i/c reducer , elbows , tees , unions , bends , sockets , flanges etc. for making water line connection forvarious package units of system etc. complete as required. , sitc of 20mm upvc pipe for plumbing work for drainage requirement i/c reducer , elbows , tees , unions , bends , sockets , flanges etc. for making water line connection forvarious package units of system etc. complete as required. , sitc of 100mm width x 50mm x 1.6mm thickness size of perforated ms cable tray i/c fabricating i/c horizontal and vertical bends reducers tees , cross members and other accessories as reqd , and duly suspended from the ceiling with ms suspenders and including paint etc. as required. , sitc of 150mm width x 50mm x 1.6mm thickness size of perforated ms cable tray i/c fabricating , horizontal and vertical bends reducers tees , cross members and other accessories as reqd , and duly suspended from the ceiling with ms suspenders and including paint etc. as required. , sitc 25mmx5mm thick g.i. strip for loop earthing on cable tray wall etc complete as required , dismantling & removing the existing laid old power/control cables of booster fans , old package units , condenser units , heaters/pre-heaters system , humidification etc. complete by unscrewing/cutting from the related m.s. racks/tray as required , lowering down the same from different floor to ground floor & shifting the same to the place inside the exchange premises as directed by eng.-in-charge. , dismantling / removing the existing fitted old defective/working/ /worn out 05 nos.package a.c. units with related condensers & accessories like canvas connection , duct damper & place at out side ac plant room at same floor etc as directed by eng.-in-charge. , recovering the existing laid refrigerant piping of old defective/working / worn out hot gas & cold gas of different sizes complete by cutting/unscrewing /opening etc. fitted in between the package unit & condenser unit lowering down the same from different floor to ground floor and shifting the same to the place inside the exchange premises/keeping in safe custody as directed by eng.-in-charge. , dismantling the existing old ducts of pac