Get complete information related to latest Foot Stand Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Foot Stand Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Foot Stand Tenders.
Tender For corrigendum : supply, installation, testing and commissioning of 500kva diesel generator set with acoustic enclosure and integration with the existing dgs_synchronization and other allied works at balasore depot under odisha state office
Tender For painting of 1st floor office area, tower inner enclosure, kerb stone along with road and part repair to security fencing wall at air dungarpur annual repair and maintenance of work for air, dungaarpur during the years 2021-22, 2023-24 and 2024-25.part repair by rough cast plaster on back side of colony entrance left side wall at air dungarpur.
Tender For supply of cms kiosk, thin client with 4gb ddr3 memory expandable to 8 gb flash rom expandable to 16 gb flash linuxembedded os suitable for existing cms kiosk, usb key board and mouse breath analyzer bio metric module, 1kva ups with 30 min. backup, touch screen 17 inch and kiosk enclosure and webcam. strictly as described incris letter no. 2007/ cris/ndls hq/cms/project/rolluot-ii/0030/pt-1 dated- 27-12-2018(encl.). special nstruction-breathanalyzer calibration should be for 3 years
Tender For supply of amalgamated pre-cooling transformer cum rectifier unit (battery charger) 200a, 130v, dc for sg ac coaches with stainless steel enclosure for charging vrla batteries confirming to rcf sp ec. no. edts.041 (rev.b) with icf amendment no.1, 2 & 3 and amended as per dy.cee/ds note no. m d/dss/spec/211 dt.11.09.2001. however, the firms may quote for latest specn./drawing with amendm ent if any issued by rdso/icf/rcf. [ warranty period: 30 months after the date of delivery ]
Tender For tender for supply of 10m frangible lattice mast with acc and frp abs encl with installation at aerodrome on runways - 10m frangible lattice with mounting accessories tool set to operate rope for tilting foundation bolts and mounting bolts etc all items required for its safe installation , frp abs enclosure type i with cooling fan vent with filter with rain shroud 1 set as per annexure iv aiv 1 aiv 2 , frp abs enclosure type ii with cooling fan vent with filter with rain shroud 1 set as per annexure iv aiv 1 aiv 3 , mounting arms 1215mm x 90mm or suitable for mounting fsm type rvr sensor temperature sensor radiation shield at 1 point 2 to 2m height from base , pipe assembly for ultra sonic wind sensor diameter 51mm and length 650mm or suitable , 230v led obstruction light for airport application , lightning arrester one set as per annexure i , frangibility certificate as per specification , drawing , din rail 3 nos , din mountable 5amps sockets 5nos , din mountable single pole mcb 2 nos , din mountable earth terminals 1no , cable tracks 2 nos , light inside enclosure 1 no , din rail 2 nos , din mountable surge protector 1 no , din mountable voltmeter 1 no , din mountable 5amps sockets 2 nos , din mountable earth terminals 1no , din mountable dual pole mcb 1 no , din mountable single pole mcb 3 nos , cable tracks 2 nos , light inside enclosure 1 no , insurance freight packing , installation charges for lattice lightning arrester and earthing for instruments as per specifications per site
Tender For supply of 415v, utilization category ac23a, 630a local isolator cabinet in sheet steel enclosure complete with 630a, 3 pole load break switch. 2. shall be with side operated handle, padlocking facility, prebreak micro switch having 1no+1nc contact. 3. micro switch contacts shall be wired to 4 sq mm tb for external termination. 4. provision of padlock system having sufficient space to lock the isolator at off position by minimum two agencies at a time. 5. complete with both power & control circuit wiring with all insulators, bus bars and control terminal blocks. 6. detachable bottom gland plate for entry of cables from bottom. 7. front door shall be hinged and inter-locked with the isolator in 'on' position. the front door should have a minimum 3 mm thickness perspex/triplex window for observation of position of contacts. 8. isolator should confirm to iec 60364 standard. 9. the dimensional drawing of the local isolator cabinet or product catalogue showing mounting arrangement of the components should be enclosed along with the offer. 10. isolator cabinet should be provided with rain canopy. 11. any isolator parts should not be made of aluminium/aluminium alloy. 12. isolator cabinet shall be metal enclosed suitable for wall fixing using 4 welded fixations, dust and vermin proof and shall be provided with degree of protection as ip-55. 13. provision for three distinct parallel busbar per phase for termination of three nos of 240 sqmm aluminum cables for incoming and two distinct busbar per phase for termination of 120 sqmm copper cable. 14. all hardware used in isolator cabinet shall be corrosion resistant. 15. minimum clearance between the live parts and detachable bottom cable gland plate shall be 400mm. 16. cabinet should be painted with alkaline resistant epoxy paint. 17. isolator cabinet shall have provision for earthing at two separate and distinct points. 18. each isolator cabinet should be supplied with panel keys., push button station specification: 1. pbs made of 2mm sheet steel enclosure with rain canopy, protection: ip-65. 2. 01 no. of green colour start pb with 1no+1nc contacts, 01 no. of red colour stop pb with 1no+1nc contacts, 01 no.of increase pb with 1no+1nc contacts <(>&<)> 01 no.of decrease pb with 1no+1nc contacts. one emergency stop push button with 1no+1nc contacts (push to lock type) shall be provided. size of each push button is of 22.5mm diameter. inscription plate for all push buttons. 3. pb shall be wired with 2.5 sq.mm. copper wire to 40 nos. serially numbered terminal blocks (tb) of elmex make having tb-5-6, 7-8, 11-12, 13-14 <(>&<)> 17-18 shorting link. 4. two nos. of cut out of size 72x72 mm for ammeter and rpm meter shall be provided. 5. 'on','off' <(>&<)> 'trip' indication led lamps in red, green <(>&<)> amber colour respectively with inscription plate to be provided. 6. all push buttons, elements, led lamps <(>&<)> cutout for ammeter <(>&<)> rpm meter shall be on the hinged door of the pb station. 7. pb station shall be weather proof, neoprene rubber gasket suitable for outdoor application. 8. 2nos. of earthing studs to be provided. 9. left side hinged door shall be provided with flexible braided copper earthing. 10. pbs shall have 04 nos. of corrosion free bracket suitable to fix on vertical surface. 11. detachable gland plate to be provided. 12. the push button shall be painted with one coat of red oxide primer <(>&<)> two coats of zinc chromate primer and finally finished with stoving enamel grey paint. 13. the push button station shall be generally in line of enclosed drawing (fig-2). 14. party to submit the drawing along with the offer for technical scrutiny.
Tender For supply of 3ph- sq. cage induction motor with highly energy efficient motor (ie3), 415v+/- 10%, 50hz+/-3%, 132kw, 315ml,4 poles, s1 duty,mounting-b3, ip-55 enclosure, tefc, ins. class: f, temperature rise limited to class-b, motor tb mounted at top, bi-directionaland provision of space heater & greasing facility