Get complete information related to latest Foundation Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Foundation Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Foundation Repair Tenders.
Tender For design, supply, fabrication, and erection of canopies with foundation, linear light fittings, roofing, false ceiling, and water drainage system with inspection chamber, hume pipe and allied works at various ros/ksks under prayagraj do of upso-i
Tender For construction of main internal gutter tambati dattamandir to mori and shri dattatrey mhamunkar foundation to main road at tambati in v.p. tambati tal khalapur dist raigad
Tender For corrigendum : construction of new s.d.o office building (g plus 1) with foundation of (g plus 4) including single story electrical sub-station building at debhog, haldia, in the district purba medinipur (phase i)..sitc of lift(mrl).
Tender For supply of electrical panel with accessories - c83640001432 supply of electrical panel along with busbar - incomer - outgoing - refer annexure 5a - scope of supply , 100000000001 supply of ip55 or above outdoor distribution box having 200a mccb 25ka incomer - refer annexure 5a - scope of supply , 100000000002 supply of ip55 or above outdoor distribution box having 150a mccb 25ka incomer - refer annexure 5a - scope of supply , 100000000003 supplying of lt power cable with aluminium conductor xlpe insulated pvc inner sheathed galvanised steel-3point5 core of size 70sqmm-refer annexure 5a-scope of supply , 100000000004 supplying of lt power cable with aluminium conductor xlpeinsulated pvc inner sheathed galvanised steel-having 3point5 core of size 300 sqmm-refer annexure 5a-scope of supply , 100000000005 supplying of end termination kit with brass compression gland and aluminium lugs for 3point5c x 70sqmm-refer annexure 5a-scope of supply , 100000000006 supply of end terminations kit of 3point5 core 300 sqmm size of cables - refer annexure 5a - scope of supply , 100000000007 supply of material for earthing with copper earth plate 600 mm x 600 mm x 3 mm thick refer annexure 5a - scope of supply , 100000000008 supply of 25 mm x 5 mm copper strip at 0point50 metre below ground -refer annexure 5a - scope of supply , 100000000009 supply of material for earthing with gi earth plate 600 mm x 600 mm x 6 mm thick -refer annexure 5a - scope of supply , 100000000010 supply of 25 mm x 5 mm gi strip at 0point50 metre below ground as strip earth electrode -refer annexure 5a - scope of supply , 100000000011 supplying of 90 mm dia od 90 mm and id 76 mm nominal size hdpe pipe isi marked-refer annexure 5a - scope of supply , 100000000012 supplying of materials for in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level -refer annexure 5a - scope of supply , 100000000013 shifting loading unloading placing installation testing and commissioning of above mentioned panel this includes foundation civil work-refer annexure 5b-scope of erection , 100000000014 shifting loading unloading placing installation testing and commissioning of above mentionedrefer annexure 5b-scope of erection , 100000000015 making end termination with brass compression gland and aluminium lugs for 3point5c x 70sqmm size of pvc insulated -refer annexure 5b - scope of erection , 100000000016 making end terminations of 3point5core 300 sqmm size of cables -refer annexure 5b - scope of erection , 100000000017 installation testing and commissioning of earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories -refer annexure 5b - scope of erection , 100000000018 installationtesting and commissioning of 25 mm x 5 mm copper strip -refer annexure 5b - scope of erection , 100000000019 installation testing and commissioning of earthing with gi earth plate 600 mm x 600 mm x 6 mm thick including accessories-refer annexure 5b - scope of erection , 100000000020 installation testing and commissioning of 25 mm x 5 mm gi strip-refer annexure 5b - scope of erection , 100000000021 laying of one number pvc insulated and pvc sheathed xlpe power cable above 35sqmm and upto 95 sqmm-refer annexure 5b - scope of erection , 100000000022 laying of one number pvc insulated and pvc sheathed xlpe power cable above 185 sqmm and upto 400 sqmm-refer annexure 5b - scope of erection , 100000000023 laying of one number pvc insulated and pvc sheathed xlpe power cable above 185 sqmm and upto 400 sqmm -refer annexure 5b - scope of erection , 100000000024 laying and fixing of one number xlpe or pvc insulated and pvc sheathed or xlpe power cable -refer annexure 5b - scope of erection , 100000000025 mouling through the existing roads in any kind of soil-laying of hdpe pipe 90mm pipes for cables etc-refer annexure 5b-scope of erection , 100000000026 excavation of the cable trenches in hard rock not exceeding 1point5 metres in width a
Tender For renovation of professors quarters p-2 and p-3 at osmania university (ou) campus for setting up of museums and ethnic research center by adidhwani foundation
Tender For supply, erection, well foundation for double pole gantry structure and stringing from oh monopole tower to gantry structure for conversion oh to ug of lilo of 110 kv kadapperi-korattur ii feeder at thiruverkadu ss
Tender For rectification of engineering defects as per rfp - defect rectification of various engineering defects as per rfp, e-647:leakage observed frequently from port gearbox lub oil cooler sea water outlet line due to deterioration. same to be renewed as per sample. (mat-cuni, l-1.5 mtr, dia-80 mm). inway job includes removal of defective line and fitment of new pipeline., e-655: abnormal vibration observed from fwd bilge & ballast pump view 02 in nos. foundation frame angles deteriorated. defective frame angles of foundation to be renewed as per sample and proved for satisfactory operation (mat:-ms, size-150x1.2x0.7 cm). in way jobs includes:- (i) removal of suction and discharge pipeline.(ii) removal of motor and pump from foundation.(iii) cutting of defective frame angles.(iv) welding of new foundation frame angles. (v) fitment of pump with motor and system lines post renewal of foundation frame angles.(vi) carrying out vibration analysis of pump., e-656: leakage and abnormal vibration observed from sea water motor driven pump of stbd gearbox. suspect mechanical seal and bearing worn out. defect to be rectified and pump to be proved for satisfactory operation. in way job includes:-(i) removal of suction and discharge pipeline.(ii) removal of pump from foundation.(iii) replacement of mechanical seal and bearings.(iv) fitment of pump and system lines post repair., e-657: the following equipment system valves are not holding due to defective valve spindle/seat. valves spindles to be renewed as per sample. valves to be overhauled and pressure tested up to test pressure. in way job includes removal and fitment of valves with associated system post repair. (mat:-brass).ser equipment size qty(a) da no. 2 & 4 sdnr (65 nb) 02 nos.(b) ro plant sdsl (25 nb) 01 no.(c) calorifier sdsl (40 nb) 01 no.
Tender For supply, erection, testing and comm. of 66kv/11kv,1x6.3mva sub-station with ht/lt switchgears and other related equip. incl., equip. foundation, cable trenches, fencing, construction of staff quarters, c. p. room, etc for nie at forelain in kathua dist. jk.