Get complete information related to latest Foundation Work Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Foundation Work Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Foundation Work Tenders.
Tender For construction bullah piling work from sanjib majumder house to tarak banik house at mouza - dhakuria , j.l no - 50, sansad no -xxvii under chandpara gram panchayat of gaighata block
Tender For supply erection, testing and commissioning of 227 m3/ hr. (50000 gph uk) or higher capacit y hscf pump set with 75hp (or higher capacity) motor 4p/tefc/ie3 horizontal foot mounted type with ratin g 415v, 50hz, 3 phase along with soft starter panel, pump set specifications shall conform to pcee/grc's l atest specification and as per site requirement annexure by consignee. the cost is inclusive of dismantling, making concrete foundationwork, supply of suitable size foundation bolts and all requisite materials. [ war ranty period: 30 months after the date of delivery ]
Tender For supply erection, testing and commissioning of 545 m3/ hr. (120000 gph uk) or higher capaci ty hscf pump set with 270hp (or higher capacity) motor 4p/tefc/ie3 horizontal foot mounted type with rat ing 415v, 50hz, 3 phase along with soft starter panel, pump set specifications shall conform to pcee/grc's latest specification and as per site requirement annexure by consignee. the cost is inclusive of dismantling , making concrete foundationwork, supply of suitable size foundation bolts and all requisite materials. [ w arranty period: 30 months after the date of delivery ]
Tender For supply erection, testing and commissioning of 227 m3/ hr. (50000 gph uk) or higher capacit y hscf pump set with 120hp (or higher capacity) motor 4p/tefc/ie3 horizontal foot mounted type with rati ng 415v, 50hz, 3 phase along with soft starter panel, pump set specifications shall conform to pcee/grc's latest specification and as per site requirement annexure by consignee. the cost is inclusive of dismantling , making concrete foundationwork, supply of suitable size foundation bolts and all requisite materials. [ w arranty period: 30 months after the date of delivery ]
Tender For corrigendum : deployment of 01 no. 150 mt capacity telescopic crawler crane for erection of structural purpose & misc. height work at inside / outside of iocl, gujarat refinery in connection with misc. civil works involving piling, civil, structural and underground piping for epcm units (gds, hcu, interconnecting pipe rack and allied areas) and design supply & construction of warehouse and associated works of petrochemical and lube integration project lupech (j-18) at iocl, gujarat refinery, vadodara, gujarat
Tender For corrigendum : supply of bulk propane lpg storage and reticulating system - supply cost of 02 nos lpg bullet and reticulating system along with all associated items , erection, commissioning, testing and trial of 02 nos. lpg bullet and reticulating system along with all associated items , supply cost of items required for conversion of furnaces no. 7350 at ngf , supply cost of items required for conversion of furnaces no. 6954 at ngf , supply cost of items required for conversion of furnaces no.6898 at ngf , supply cost of items required for conversion of furnaces no. 6963-07 at rfs , supply cost of items required for conversion of furnaces no. 6963-08 at rfs , supply cost of items required for conversion of furnaces no. 6963-09 at rfs , supply cost of items required for conversion of furnaces no. 6963-10 at rfs , supply cost of items required for conversion of 50 ton wellman wacoma furnaces at rfs , charges of conversion, trial and testing for furnace no.7350 at ngf , charges of conversion, trial and testing for furnace no. 6954 at ngf , charges of conversion, trial and testing for furnace no. 6898 at ngf , charges of conversion, trial and testing for furnace no. 6963-07 at rfs , charges of conversion, trial and testing for furnace no. 6963-08 at rfs , charges of conversion, trial and testing for furnace no.6963-09 at rfs , charges of conversion, trial and testing for furnace no. 6963-10 at rfs , charges of conversion, trial and testing for 50 ton wellman wacoma furnaces at rfs , accessories and other essential items, if any , packing and forwarding charges for whole plant , freight and insurance charge for whole plant , civil foundationwork for whole plant , civil structural or building work for whole plant , training chages
Tender For stone pitching from km. 6.968 to km. 89.367 on existing pucca structures to upstream and downstream and ballie piling work at vulnerable place from km. 48.850 to km. 89.367 of lower ganga canal.
Tender For corrigendum : special repair for renewel of e/m items and plant/ machinery held in charge of age (e/m) rnd agra cantt under ge (i) rnd delhi - supply , installatation , testing and commissioning of diesel driven generating set to give an out put of 500 kva, 415v ac supply 3 phase, 50 hz, 4 wire radiator mounted on common base plate complete with fuel tank, vibration damper and other accessories with fuel tank viberation damper and other accessories with acoustic enclouser as per latest cpcb-iv norms and amf panel including pcc foundationwork as per oem reccommandation and taking out the old dg set from the location and deposited to mes store yard complete all as specified and directed, interanally comprising of following :-(a) diesel driven engine :- developing a net output suitable matched to give a net rated output of minimum 604 hp/suitable to drive 500 kva alternator, at 0.8 power factor 415 volts. the engine should be capable of delivering the required output at 1500 rpm, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified.(i) fly wheel to suit flexible coupling and fly wheel housing.(ii) air cleaner complete as per manufacturer specification. (iii) fuel injection pump. (iv) flexible coupling with guard, nuts and bolts.(v) fuel filter with mounting. (vi) oil filter with mounting.(vii) starter motor as per manufactures design.(viii) exhaust, silencer industrial type with exhaust pipe suitable length.(ix) batteries 12 volts 2x180 ah maintenance free batteries with copper lead, terminals etc.(x) instrument panel complete with microprocessor based controller comprising shut down valve indication, lcd hour counter indication, rpm indication , led lamps for fail to start, over speed /under speed . low lub oil pressure, high engine coolant temperature. gaugae.(xi) dynamo/alternator suitable rating., (b) alternator :-the above engine will be coupled through flexible coupling on an indigenous alternator mounted on a strong steel fabricated common base frame suitable for mounting in an acoustic enclousre. the alternator will be 3 phase 50 hz 1500 rpm self regulating self exciting type and have class h insulation of stator and rotor windings and generate 500 kva output at .8 power factor 4 wire 415 volts ac supply under ntp condition with a provision of 10% overload for 1 hour in every 12 hrs running. the alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.(c) control panel :- s&f amf (automatic on mains failure) control panel cpri approved outdoor ype kiosk water, dust and vermin proof and fabricated out of 3.15 mm thick crca sheet and 50mm x 50mm x 6mm angle iron powder coated suitable for 415 volts 3 phase 50 hz ac supply with and incl the following :-(i) mccb of suitable capacity(ii) necessary relays, times and power contractors of suitable rating/capacity for auto on-off the dg set and changeover of the load in case of power failure.(iii) digital mulfifunctional meter for phase wise reading of amps, voltage kwh and frequency -01(iv) internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses.(v) earthing terminals 02 nos(vi) auto/manual start switch to by pass auto start.(vii) battery charging system suitable for charging for charging the battery provided with the dg set incl boost/stickle switch and system, dc voltmeter digital type., (d) fuel tank :- one no built in sheet metal steel tank mounted inside the acoustic encloser and of adequate capacitynot less than 740 ltr with inlet and outlet connection including the following :-(i) level indicator with float and gauge.(ii) fuel piping for fuel supply to engine and over flow to tank(iii) fuel strainer(e) acoustic enclosure :- enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per is 8528 part 10 and as per approved cpcb morms. the acous