Get complete information related to latest French Straw Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic French Straw Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding French Straw Tenders.
Tender For providing ramp at nav bhavan, replacement of wooden shutter at first floor exchange building and other miscellaneous work.subwork/packages:na
Tender For bid to ras corrigendum : repairing and servicing of rocking roller , repairing and servicing of plan roller , repairing and servicing of sway brace , repairing and servicing of transoms clamps , repairing and servicing of chesses wooden , repairing and servicing of bracing bolt , repair servicing and painting of panel , repair servicing and painting of stringer plain , repair servicing and painting of stringer button , repair servicing and painting of ramp button , repair servicing and painting of ramp plain , repair servicing and painting of transom , repair servicing and painting of base plate , repair servicing and painting of raker , repair servicing and painting of end post male , repair servicing and painting of end post female , repair servicing and painting of bearing , repair servicing and painting of crib bearing , repair servicing and painting of plain roller , repair servicing and painting of rocking roller , repair servicing and painting of foot walk post , repair servicing and painting of foot walk bearer , repair servicing and painting of sway brace , repair servicing and painting of bracing frame , repair servicing and painting of chasses steel double end
Tender For supply of sundry materials transportation earthing arrangements electrification of control room building tp items and furnitures required towards establishment of new 33kv indoor ss at ottiyambakkam arasankazhani village - supply of materials, ms channel 100mm x 50mm, ms angle 65mm x 65mm, ms flat 50 x 8mm, ms rod 40mm dia, 33kv, 1x630 sq.mm, aluminium clamp, 11kv, 1x630 sq.mm, aluminium clamp, rubber mat, plastic name board ( feeder name, lc board, back charged etc.,), 33kv & 11 kv breaker name plate details stickers, first aid box, wall clock, entrance floor mat, welcome mat, schematic layout board ( wooden / plastic / aluminium) having the size of 1200mm x 600 mm and board covered with 3mm thick achorlic transparent sheet., earthing layout board ( wooden / plastic / aluminium) having the size of 1200mm x 600 mm and board covered with 3mm thick achorlic transparent sheet., transportation & labour works, labour charges for transporting the 33kv vcb panel having 2m to 2.5m height and 3m length and weighing of about 3.5 tonne carefully from cdc stores to newly proposed 33/11kv indoor ss at arasankazhani, chennai. including loading and unloading moving safely by use of cranes. this includes moving the package from inside the store shed to its ramp and inside to the substation control room (transformer panel 2 nos., + feeder panel 3 nos + bus coupler and adaptor panel), labour charges for transporting the 11 kv vcb panel having 0.9m width 3m height and 2.5m length and weighing 1.5 tonne carefully from cdc stores at ambattur to newly proposed 33/11kv indoor ss at arasankazhani, chennai. including loading and unloading moving safely by use of cranes. this includes moving the package from inside the store shed to its ramp and inside to the substation control room. (transformer panel 2nos., feeder panel 6 nos., bus coupler and bus adopter), labour charges for marking on the floor and chipping of foundation holes in complete alignment embadding of channel for erection of breaker and grouting the 33kv vcbs., labour charges for marking on the floor and chipping of foundation holes in complete alignment embadding of channel for erection of breaker and grouting the 11kv vcbs, labour charges for drawal of 33kv,1x630 sq.mm, xlpe, ug, cable from cdc stores at ambattur and transporting to work site in lorry and laying the same in side duct from power transformer i & ii to hv breaker i & ii, labour charges for drawal of 11kv,1x630 sq.mm, xlpe, ug, cable from cdc stores at ambattur and transporting to work site in lorry and laying the same in side duct from power transformer i & ii to lv breaker i & ii, labour charges for drawal of 1.1kv armoured copper control cable from cdc stores at ambattur and transporting to work site in lorry and laying the same in side duct on g.i.tray for ss equipments., earthing arrangements, labour charges for drawal of 40dia m.s rod from departmental stores and transporting to worksite inlorry (including loading & unloading) and labour charges for auguring to a depth of 6mtr/20ft and fixing the m.s round rod 40mm dia board supply and making m.s clamping arrangement in top of the rod and 4nos 12mm dia holes in clamp for inter linking of m.s. flats in any kind of soil and fixing with gem and burried in ground and as directed by site in charge. (ground enhancement material to be supplied by the contractor )(6m x 12nos = 72mts), labour charges for drawal of m. s. flat of size. 50mm x 8mm from departmental stores and transporting to worksite in lorry (including loading & and unloading) and labour charges for laying, cutting welding and painting of ms flat of size 50 x 8 mm and interconnecting . the plate should be burried at a depth of 2 feet depth or laid in duct as per site condition and clamped out one meter interval. m.s flat will be supplied by the board and painted with twin coat redoxide and enamal green paint before laying and as directed by site in charge. (as per drg.), fabricati