Get complete information related to latest Frequency Counter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Frequency Counter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Frequency Counter Tenders.
Tender For tender for supply of m and l for searching fault location of ht ug cable 11000 volts laid in trenches ducts with the help of electronic fault locating machine comprising of surge generator pulse echo fault locator with frequency distance calculator etc incl transportation of machinery excavation in normal soil strata exposing the cable fault removal of deteriorated portion of the cable treating of cable of any size including disconnecting and re fixing cables with lugs as per direction of engineer in charge note a charges of cable fault locator and dg set including transportation charges deemed to be included in the quoted rate b necessary testing of cable after making joint will be deemed to be including in the cost of relevent item , supply jointing and testing indoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core x 120 minus 185 sqmm xlpe cable of 11000 volts e grade complete all as specified and directed note cost of cutting of existing end termination joint deemed to be included in unit rate , m and l for cable jointing kit for 11 kv earthed grade cable for straight through cold shrink type complete with joining material and accessory suitable for 120 to 185 sqmm 3 core xlpe armored aluminum conductor cable complete all as specified and directed , supplying and laying in repair xlpe insulated screened pvc bedded galvanized steel strip or wire armoured , electrical power cable heavy duty with aluminum conductor 11000 volts grade cross sectional area 120 sqmm x 3 core complete all as specified and directed , supply and fixing in repair mccb 400 amps 3 pole 415 volt 36 ka including under voltage over voltage relay with adjutable thermal setting 80% minuse 100% all as specified and directed , m and l for complete repairing serviceing of ht 11 kv vaccum circuit breaker vcb after disconnecting of all incoming and outgoing connection checking finding of the defective spare parts removing of all moisture content with suitable grade chemical replacement of rusted nuts bolts and washer replacement of all unserviceable post insulator and repair of all busbar joints and covered with ht insulation tape complete external surface as per existing colour and quality replacemnt of all defective internal ac dc circuit wiring repair servicing of breaker trolly including motorized operating mechanism ct pt power pack and calibration of triping relays system and tripping mechanism for regulating the fault flow over current earth fault differential in sequence from down streem to receiving sub stn for accuracy and effective functioning of vcb complete all as specified and as directed note nuts bolts washer cleaning material insulation tape copper wire for circuit wiring and defective ht 11 kv 2 amp fuse carrier oiling greasing to charging spring replacement of hrc fuse 110 220 volt 5 amps setting of over current earth fault relays complete other minor items for repair of breaker shall be deemed in qouated rate replacement of major unserviceable spares accessories shall be measured and paid separately under relevant items , supply and fixing heater 230 volts ac 60 watt for 11 kv ht vcb panel complete all as specifed and as directed make heatco vileco electrical , supply and fixing in replecement of spring charging gear for 11kv vcb panel suitable for 630 400 amp complete all as specified and directed , supply and fixing vacuum interputer for ht11 kv vcbs 630 400 amps brakding capacity 13point 1 ka suitable for alstom make vcb complete all as specified and as directed , taking down and repairing overhauling of air break gang operated switch with do fuse unit 200 amp 400 amp capacity triple pole mechanically operated mounted on insulators and steel frame installed vertically horizontally replacement of broken worn out components oiling and greasing of mechanical moving parts smoothing and polishing of electric contacts with providing conducting jelly of contacts refixed the same after re
Tender For supply of electrical and electronics laboratory setup - rlc resonance trainer kit series and parallel resonance, kit consists of voltmeter and frequencycounter, inbuilt signal generator, experiments can be performed with or without oscilloscope inbuilt power supply, maximum power transfer theorem trainer kit maximum power transferred from a source to a load when the load resistance is made equal to the internal resistance of a source. inbuilt fixed dc regulated power supplies : 12vdc, meters, ammeter & voltmeter, required components provided, circuit diagram printed on front panel & all important test points are brought out on front panel power requirement : 230 vac, clamp on meter suitable for min 300 a ac/dc current measurement range: 0.2 to 300 a, accuracy 1.5% ac voltage: mv to 1000 vac, accuracy: 0.75% dc voltage: 30mv to 1000 vdc, accuracy: 0.5% resistance: upto 30 mohm, accuracy: 0.5% capacitance 1 nf to 30 micro f, accuracy: 1% frequency upto 100 khz, accuracy: 0.5% auto hold, max/min, auto/manual, diode, ip20 protection., digital meter: portable table top type, with cabinet and stand, terminals brought out for connections, range: voltmeter:0-750v ac 0-500 vdc, ammeter:0-20a ac 0-20a dc 2 nos each range, electronic energy meter( single phase) 240vac, 20aac, electronic energymeter( three phase) 400 vac, 30 aac, digital multimeter ¾ digit , true rms ac voltage range : 1 mv to 1000v, accuracy < 1% dc voltage range : 10 mv - 1000 v, accuracy < 0.5% ac current range : 1 ma-10a, accuracy < 2%, dc current range 0.01 ma-10a, accuracy < 1.5%, resistance: 100 mohm-60 mohms, accuracy < 0.5% input impedance: 10mohm capacitance: 1 nf – 60 mf, accuracy: < 5%, frequency: 0.01 hz – 10 khz, accuracy < 0.1% duty cycle, temperature and diode test, lcd display with auto / manual range , included accessories: test leads, rubber holster, temperature probe, battery charger 12 / 24v dc, 15 a, digital power factor meter, portable bench top type, with cabinet and stand, terminals brought out for connections, range: single phase, 220v ac, 5a, digital frequency meter, portable bench top type, with cabinet and stand, terminals brought out for connections, range: 45-55 hz, digital wattmeter, portable bench top type, with cabinet and stand, terminals brought out for connections, range: 220v, 5a ac single phase (2 nos) 400 v, 5a ac, three phase (2 nos), single phase half wave, full wave , fully controlled bridge rectifier / converter design to study to controlled rectifier & observe wave form on cro. meters provided of suitable range, in built power supply. load resistance, controls for phase angle. circuit diagram printed, & test points brought out on front panel. power requirement: 230 vac +10%, 50hz. supplied with patch chords & instruction manual, ups trainer kit input range: 170 to 270 v, ac output (input present): 195 to 250 v capacity: 200 w battery: 12 v / 7 ah, maintenance free, test points for experimentation purpose. panels: input / output / battery / transformer / avr / charger /inverter study of charger study of changeover logic study and working of ups, smps trainer kit input : 110- 230v, output : 12v dc, switching transformer, scr commuation trainer kit two dc regulated power supplies 0-30vdc/150ma & 0-1 vdc/150ma, three meters for voltage & current measurement , scr 2p4m mounted behind the panel, connections of supplies, meters & scr brought out at 4mm sockets., characteristics trainer kit for scr,diac,triac, ujt,igbt instrument comprises of three dc regulated power supplies 0-15 vdc/150ma, 0-50 vdc/150ma & 0-2.5 vdc/150ma, four round dual range meters for voltage & current measurement,ujt, scr, diac, triac & their supportive components mounted behind the panel, connections of supplies, meters & components brought out at 4mm sockets., kit for speed control of dc motor using microcontroller eters (digital) :0-200v dc, 0-500ma dc instrument provided with 1/12 hp dc motor, on board phase a
Tender For procurement of spares for mi-17v5 helicopter - cable equipment, collective patch tester, compressor rotor 1st stage blade wear control device, antenna matching unit, vibration balancing analyser equipment with main and tail rotor kit, hoist, combination test, attenuator, frequencycounter(upto 500 mhz), indicator, modulation depth and frequency deviation meter, spectrum analyzer, test programming set for cma-2012, device, lamp, test panel for testing fire protection system ssp-fk