Get complete information related to latest Fuse Plate Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fuse Plate Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fuse Plate Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :42935611 Due date: 10 Dec, 202510 Dec, 2025 49.00 Lacs
Tender For repair/maint and improvement of lt panel including lt switch gear earthing timer panel lt poles pole box outdoor street lights flood lights area lights lt distribution network and connected items at bs marg def colony 6/11 gr unit 4/3 gr 16 rajput

Central Government/Public Sector

CTN :42937156 Due date: 10 Dec, 202510 Dec, 2025 49.00 Lacs
Tender For repair/maint and improvement of lt panel incl lt switch gear earthing timer panel lt poles pole box outdoor street lights flood lights area lights lt distribution network and connected items at otm/md accn of skp lbs marg usman road surya canteen

Central Government/Public Sector

CTN :42985326 Due date: 20 Dec, 202520 Dec, 2025 49.00 Lacs
Tender For repair maintenance and improvement of lt panel including lt switch gear, earthing, timer panel, lt poles, pole box, outdoor street lights, lt distribution network at neil line, otc, 1tt, 2tt, adm bn, 2mt, 1mt and adjoining area of age e/m ext(elect)

Central Government/Public Sector

CTN :42985333 Due date: 20 Dec, 202520 Dec, 2025 49.00 Lacs
Tender For repairmaint and improvement of lt panel including lt switch gear earthing timer panel lt poles pole box outdoor street lights lt distribution network at sanjog chetri vihar old siya line new siya line hudson line adjoining area of age e/m ext(elect)

Central Government/Public Sector

CTN :42987146 Due date: 20 Dec, 202520 Dec, 2025 49.00 Lacs
Tender For repair maintenance and improvement of lt panel including lt switch gear, earthing, timer panel, lt poles, pole box, outdoor street lights, lt distribution network at ggs marg, afmsd, stn wksp, hudson line and adjoining area of age e/m ext(elect)

Central Government/Public Sector

CTN :42956361 Due date: 26 Dec, 202526 Dec, 2025 61.87 Lacs
Tender For provisioning of electrical and mechanical eqpt against ber under ge 862 ews - supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 300 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type(m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 450 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fitting & accessories e.g marking plate, lifting lugs, ci rollers, earthing terminals, cable box including suitable platform as reqd on site complete all as as specified & directed., supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 100 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type (m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 150 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fi

CTN :42963969 Due date: 13 Dec, 202513 Dec, 2025 1.05 Lacs
Tender For tender for supply of earthing chemical copper , wiring office , ups bypass switch servo bypass swutch , mcb/db box , flexible pipe , flexible pipe

State Government

CTN :42919224 Due date: 01 Dec, 202501 Dec, 2025 2.44 Lacs
Tender For - tender for aug. of existing 250kva, 11/0.4 kv s/stn. jibhi into 400kva, 11/0.4 kv s/stn. in (e ) section jibhi uesd, hpsebl, banjar. (t.s. 09/2025-26) - supply part dtr 400 kva, supply of lt distribution panel box suitable for 400 kva s/stn of size 1100x800x275mm +/- 5% made of steel sheet of 1.63 mm thickness having double door locking arrangement duly powder coated painted complete withlt distribution panel box with mccb 630 amp 3p 50ka-1 no. make l&t , schneider and abb only, mccb 250 amp 36ka 3p of l&t schneider and abb make only 3no. mccb rating 250amp, 3 poles having following specifications (1) minimum frame size 250 amp (2) type variable trip free, (3) breaking capacity- isu & lcs at 415, 50 hz (ka: not less than 50 ka) (4) , thermal release range: 320-440amp (5) mecanical life (operation) 20000 no. (6) electrical life (operation) 4000 no. (7) rated insulation voltage (v) 690v (8) tripping thermal releasing setting : thermal-o/l variable setting (9) tripping magnetic releasing setting : magnetic- s/c fixed setting (12) in (10) (operation) volatge 415v, ac (11) caliberation temperature: 40 degree c (12) high voltage withstand voltage : 3kv for 1 minute (13) confirming to is : 1993/60947-2, 1989 (14) make l&t/ havells/abb/ hpl/ schiender and approved vendor of hpsebl (15) ics : 100% icu reangular type aluminum alloy bus bar of 250 amp. having length 800 mm of phase 800 mm long for netural outgoing feeder 3 nos. outgoing feeders shall be made in the pannel u type single pole mccbs of 400 amp. shall be provided in all 3- phases. the panel shall be fully wired with insulated copper wire have adequate clearance . as per standard specification, supply of aluminium thimble, supply of aluminium thimble, supply of lt cable (3.5 core ) 400 mm2 (incomer), supply of lt cable (3.5 core ) 240 mm 2 (outgoing), erection of dtr, erection of 400 kva , 11/0.433kv dtr, erection of lt box, providing earthing connection including g.i.wire to g.o switch erection of jumper, laying of lt cable, complete in all respect., transportation charges inclusive of hydra crane charges and mannual carriage of dtr and its associate material., add dismantling charges of old dtr (250 kva dtr) and allied accessories @50% of erection of new dtr.

State Government

CTN :42971512 Due date: 15 Dec, 202515 Dec, 2025 NA
Tender For painting of different size earthing ct pt isolator junction box at 132 kv ss pasahi under etd robertsganj

State Government

CTN :42956457 Due date: 26 Dec, 202526 Dec, 2025 NA
Tender For cost estimate for painting of equipment earthing strip, cb marshaling box, ac qubical box etc. of 400 kv side switchyard at 400 kv sub station motiram adda, gorakhpur under e400kv s/s division gorakhpur.